A 3D FEM Model for Laterally Loaded Drilled Shafts in Rock

Author(s):  
Ke Yang ◽  
Robert Liang
Author(s):  
Yee Wong Soon ◽  
◽  
Ti Kok Sien ◽  
Kang Choong Wee ◽  
Abdullahi Ali Mohamed ◽  
...  
Keyword(s):  
3D Fem ◽  

Author(s):  
Fabiano Bini ◽  
Andrada Pica ◽  
Simone Novelli ◽  
Raffaella Pecci ◽  
Rossella Bedini ◽  
...  

2016 ◽  
Vol 6 (1) ◽  
pp. 7-15
Author(s):  
Daniela Mihaela Boca ◽  
A. Faur ◽  
A. Boca

Abstract This study aims to presents the importance of end constrains, boundary conditions and position of the applied forces regarding the design of precast/prestressed concrete box girders. The study is based on a destructive test which was performed on a 37.1 m span single-cell prestressed concrete box girder. The scope of the test was to certify the usage of such girders for the new Transylvania motorway bridges. The test is numerically reproduced through a full 3D FEM model implemented in SAP2000. The influence of the end diaphragms is considered by analysing the beam’s behaviour to six loading conditions: one of which is replicating the loadings during the test, while the others are conceived as real vertical and horizontally loading scenarios. The results obtained for the girders with and without end constrains are compared. The performances of both design solutions in the presence of prestressing are highlighted where applicable. It is considered that the results of this study may provide very important data if considering that Romania has an urgent need to realize a modern and an adequate transport infrastructure.


2012 ◽  
Vol 226-228 ◽  
pp. 13-16
Author(s):  
Xin Wang ◽  
Shao Ze Luo

In order to study the flow-induced vibration of the spillway tunnel working gate of one reservoir, hydraulic model test with scale 1:20 was conducted to obtain the dynamic pressure characteristics on the working gate. Experiment modal analysis method was employed to identify the structure dynamic characteristics through the 1:10 working gate mode test. The 3D FEM model of the gate was built to simulate the vibration response of the structure. The research showed the low order modal frequencies of the working gate were not fully breaking away from the high energy zone of the dynamic water, which would induce severe vibration. The vibration response of the gate became the biggest when it was operating at 0.5 partial opening.


2016 ◽  
Vol 13 (5) ◽  
pp. 652-664 ◽  
Author(s):  
Jesús Fernández Ruiz ◽  
Pedro Alves Costa ◽  
Rui Calçada ◽  
Luis E. Medina Rodríguez ◽  
Aires Colaço

Sign in / Sign up

Export Citation Format

Share Document