Shock propagation, preheat, and x-ray burnthrough in indirect-drive inertial confinement fusion ablator materials

2004 ◽  
Vol 11 (5) ◽  
pp. 2778-2789 ◽  
Author(s):  
R. E. Olson ◽  
R. J. Leeper ◽  
A. Nobile ◽  
J. A. Oertel ◽  
G. A. Chandler ◽  
...  
2009 ◽  
Vol 27 (1) ◽  
pp. 123-127 ◽  
Author(s):  
A. Seifter ◽  
G.A. Kyrala ◽  
S.R. Goldman ◽  
N.M. Hoffman ◽  
J.L. Kline ◽  
...  

AbstractImplosions using inertial confinement fusion must be highly symmetric to achieve ignition on the National Ignition Facility. This requires precise control of the drive symmetry from the radiation incident on the ignition capsule. For indirect drive implosions, low mode residual perturbations in the drive are generated by the laser-heated hohlraum geometry. To diagnose the drive symmetry, previous experiments used simulated capsules by which the self-emission X-rays from gas in the center of the capsule during the implosion are used to infer the shape of the drive. However, those experiments used hohlraum radiation temperatures higher than 200 eV (Hauer et al., 1995; Murphy et al., 1998a, 1998b) with small NOVA scale hohlraums under which conditions the symcaps produced large X-ray signals. At the foot of the NIF ignition pulse, where controlling the symmetry has been shown to be crucial for obtaining a symmetric implosion (Clark et al., 2008), the radiation drive is much smaller, reducing the X-ray emission from the imploded capsule. For the first time, the feasibility of using symcaps to diagnose the radiation drive for low radiation temperatures, <120 eV and large 0.7 linear scales NIF Rev3.1 (Haan et al., 2008) vacuum hohlraums is demonstrated. Here we used experiments at the Omega laser facility to demonstrate and develop the symcap technique for tuning the symmetry of the NIF ignition capsule in the foot of the drive pulse.


Author(s):  
C. W. Price ◽  
E. F. Lindsey

Thickness measurements of thin films are performed by both energy-dispersive x-ray spectroscopy (EDS) and x-ray fluorescence (XRF). XRF can measure thicker films than EDS, and XRF measurements also have somewhat greater precision than EDS measurements. However, small components with curved or irregular shapes that are used for various applications in the the Inertial Confinement Fusion program at LLNL present geometrical problems that are not conducive to XRF analyses but may have only a minimal effect on EDS analyses. This work describes the development of an EDS technique to measure the thickness of electroless nickel deposits on gold substrates. Although elaborate correction techniques have been developed for thin-film measurements by x-ray analysis, the thickness of electroless nickel films can be dependent on the plating bath used. Therefore, standard calibration curves were established by correlating EDS data with thickness measurements that were obtained by contact profilometry.


2020 ◽  
Vol 36 ◽  
pp. 100749 ◽  
Author(s):  
R.E. Olson ◽  
R.J. Leeper ◽  
S.H. Batha ◽  
R.R. Peterson ◽  
P.A. Bradley ◽  
...  

2011 ◽  
Vol 18 (3) ◽  
pp. 032706 ◽  
Author(s):  
R. E. Olson ◽  
G. A. Rochau ◽  
O. L. Landen ◽  
R. J. Leeper

Sign in / Sign up

Export Citation Format

Share Document