Measurement of Particle Size Distribution and Volume Concentration based on Ultrasonic Attenuation Spectrum in Fat Emulsion

2007 ◽  
Author(s):  
Lili Dong ◽  
Mingxu Su ◽  
Minghua Xue ◽  
Xiaoshu Cai ◽  
Zhitao Shang
1955 ◽  
Vol 28 (3) ◽  
pp. 922-926
Author(s):  
A. J. De Vries ◽  
M. Van den Tempel

Abstract Some rheological properties of hydrogels made from Hevea latex have been determined by shear measurements, using a hollow cylindrical test piece. The shear modulus and the viscosity depend on the volume concentration of solids in the gel, the composition of the interfacial layer surrounding the rubber globules, and the particle-size distribution of the rubber globules. An interpretation of the experimental results is given, based on the assumption that no coalescence of the rubber particles occurs. The rheological properties of the gel should then be functions of the number of points of contact between the particles and of the strength of the bonds between the particles in the gel.


2019 ◽  
Vol 2019 ◽  
pp. 1-12
Author(s):  
Nan Jia ◽  
Jianfei Gu ◽  
Huinan Yang ◽  
Mingxu Su

Particle sizing methods have gained considerable attention in the past few decades, but there is still a big challenge in high concentration situations (i.e., volume fraction>10%). However, the ultrasonic spectroscopy technique is a common tool for the noninvasive determination of essential parameters for high concentration systems by analyzing ultrasonic spectra with inversion algorithms, including the particle size distribution (PSD), volume fraction of each phase, and physicochemical properties. For the ultrasonic measurements, proper acquisition and analysis of ultrasonic spectra are becoming significant in order to understand the relationship between the unknown parameters and the ultrasonic spectra. In the work, an experimental setup was provided to synchronously acquire ultrasonic reflection and transmission signals. A series of experiments were performed on silicon-water solutions at volume fractions 8%, 10%, and 12% to obtain the ultrasonic attenuation spectra and ultrasonic phase velocity spectra based on different measurement methods, i.e., the pulse-echo method, reference reflection method, and through-transmission method, respectively. Based on the Epstein-Carhart-Allegra-Hawley (ECAH) forward model, genetic algorithm (GA) and optimum regularization technique (ORT) algorithms were implemented to determine PSD with the measured spectra; the obtained PSD was then compared with the optical microscope method. It revealed that the spectra obtained by different measurement methods showed individual features while the obtained PSD was consistent and the volume median diameters were within a deviation of 10% with GA and ORT algorithms. The differences and characteristics of these three measurement methods for signal acquisition and interpretation were discussed and presented to provide an evaluation and recommendation for ultrasonic particle sizing.


1992 ◽  
Vol 49 (11) ◽  
pp. 2749-2755 ◽  
Author(s):  
Rahul C. Mehta ◽  
Lisa F. Head ◽  
Azar M. Hazrati ◽  
Michael Parr ◽  
Robert P. Rapp ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document