The Chicago Water Isotope Spectrometer (ChiWIS-lab): A tunable diode laser spectrometer for chamber-based measurements of water vapor isotopic evolution during cirrus formation

2020 ◽  
Vol 91 (4) ◽  
pp. 045120
Author(s):  
Laszlo C. Sarkozy ◽  
Benjamin W. Clouser ◽  
Kara D. Lamb ◽  
Eric J. Stutz ◽  
Harald Saathoff ◽  
...  
1994 ◽  
Vol 33 (24) ◽  
pp. 5506 ◽  
Author(s):  
Haris Riris ◽  
Clinton B. Carlisle ◽  
Russell E. Warren

1988 ◽  
Vol 43 (5) ◽  
pp. 402-406 ◽  
Author(s):  
Thomas Giesen ◽  
M. Harter ◽  
R. Schieder ◽  
G. Winnewisser ◽  
K.M.T. Yamada

The high resolution spectrum of the 2 υ9 band of HNO3 has been recorded by a tunable diode laser spectrometer with a newly developed frequency stabilization technique. The spectral data were digitally stored and processed by a dedicated micro-computer in order to improve the sensitivity and the precision of the measurements. In addition to the anomalies due to the Fermi resonance with the υ5 = 1 state, we have observed the line doubling caused by the internal rotation of the OH group.


1989 ◽  
Vol 44 (7) ◽  
pp. 633-639 ◽  
Author(s):  
S. Dobos ◽  
G . Winnewisser ◽  
F. Kling ◽  
J. Mink

The absorption spectra of carrier free 14C16O2 in the spectral range of 2290-2150 cm−1 by a medium resolution FTIR spectrometer, and the spectral region of 2258 − 2229 cm−1 with a high resolution tunable diode laser spectrometer have been recorded. Spectroscopic constants were calculated from the 0001 − 0000 and 0111 −0110 transitions.


1993 ◽  
Author(s):  
Shachar D. Nadler ◽  
David R. Karecki ◽  
Gervase I. Mackay ◽  
Harold I. Schiff

2004 ◽  
Vol 79 (7) ◽  
pp. 915-921 ◽  
Author(s):  
A. Ray ◽  
A. Bandyopadhyay ◽  
B. Ray ◽  
D. Biswas ◽  
P.N. Ghosh

1986 ◽  
Vol 120 (2) ◽  
pp. 239-245 ◽  
Author(s):  
K.B. Thakur ◽  
Curtis P. Rinsland ◽  
Mary Ann H. Smith ◽  
D.Chris Benner ◽  
V. Malathy Devi

2022 ◽  
Vol 961 (1) ◽  
pp. 012081
Author(s):  
Ruaa Kahtan Mahmood ◽  
Samira Adnan Mehdi

Abstract By modifying the wavelength of the open path tunable diode laser spectrometer (TDLS) in the near infrared region, theoretical research was implemented to improve the detection limit of carbon monoxide gas. To adjust the correct wavelength in the NIR area, MatLab code was created. Following that, frequency domain measurements were performed in order to extract the second harmonic as an indicator of gas presence. According to the results, the correct wave length in the NIR area is (1584.877 nm), and the lowest limit of CO gas concentration is (0.012 ppb).


Sign in / Sign up

Export Citation Format

Share Document