scholarly journals Structural evidence that human liver and placental alkaline phosphatase isoenzymes are coded by different genes.

1976 ◽  
Vol 73 (7) ◽  
pp. 2201-2205 ◽  
Author(s):  
K. S. Badger ◽  
H. H. Sussman
1976 ◽  
Vol 22 (7) ◽  
pp. 972-976 ◽  
Author(s):  
H Van Belle

Abstract I studied the kinetics and sensitivity toward inhibition by levamisole and R 8231 of the most important human alkaline phosphatase isoenzymes. N-Ethylaminoethanol proved superior to the now widely used diethanolamine buffer, especially for the enzymes from the intestine and placenta, behaving as an uncompetitive activator. The optimum pH largely depends on the substrate concentration. The addition of Mg2+ has no effect on the activities. The meaning of Km-values for alkaline phosphatases is questioned. Isoenzymes from human liver, bone, kidney, and spleen are strongly inhibited by levamisole or R 8231 at concentrations that barely affect the enzymes from intestine or placenta. The inhibition is stereospecific, uncompetitive, and not changed by Mg2+. Inhibition is counteracted by increasing concentrations of N-ethylaminoethanol. The mechanism of inhibition is suggested to be formation of a complex with the phosphoenzyme.


1979 ◽  
Vol 25 (7) ◽  
pp. 1230-1233 ◽  
Author(s):  
G J Doellgast ◽  
P J Meis

Abstract We used the inhibitors bromotetramisole, L-phenylalanine amide, and L-phenylalanine in combination to measure intestinal phosphatase in maternal serum and amniotic fluid. By using high concentrations of these inhibitors, it was possible to measure the three isoenzymes separately. We found no evidence of the presence of meconial alkaline phosphatase in the serum of the mother (six cases) after meconial passage in utero.


2020 ◽  
Vol 154 (Supplement_1) ◽  
pp. S8-S8
Author(s):  
Kayode Balogun ◽  
Megan Lee ◽  
Kelly Doyle

Abstract Introduction Alkaline phosphatase (ALP) is important in the diagnostic work-up for hepatobiliary and bone diseases. ALP isoenzymes are expressed in the bone, liver, kidney, placenta, and intestine, and vary in heat stability and electrophoretic mobility. Distinguishing the different ALP isoenzymes is clinically important for the diagnosis of pathologies associated with elevated ALP activity. Current modalities available to measure ALP isoenzymes utilize the heat stability, electrophoretic mobility, and immunochemical properties of the isoenzymes. The differences inherent in these methods allow for unique benefits of each method in identifying ALP isoenzymes. The objective of this study was to compare bone, liver, and placental ALP isoenzyme results determined by heat fractionation and gel electrophoresis and to characterize the heat-stable non-liver fraction (t1/2 >11 min), reported by heat fractionation, using gel electrophoresis. Methods A total of 72 de-identified serum samples that span a wide range of known ALP isoenzyme concentrations and disease states were used to measure ALP using gel electrophoresis and heat fractionation. Heat fractionation was achieved by selective inactivation of the isoenzymes at 56 °C in 10, 15, and 20-minute intervals. Log-percent activity of the total and heat-inactivated fractions at each time point was plotted against time in minutes. The linear activity decay between 10 and 20 minutes determined the relative amount of liver isoenzyme activity and the slope of the line determined the half-lives of ALP isoenzymes. Electrophoresis was performed according to the manufacturer’s protocol using the Hydragel ISO-PAL gel to resolve ALP isoenzymes based on their electrophoretic mobility and interaction with lectin. ALP isoenzymes were quantified by densitometry. Results Our results show a significant correlation coefficient (r) of 0.98, Deming regression slope of 1.1, and bias of -1.2% for the liver isoenzyme (n=43). However, liver fractions are not distinguishable by heat fractionation when heat-stable isoforms are present. The bone fraction (n=43) showed a coefficient of correlation of 0.86, slope of 0.55, and bias of -31%. Although, with a small sample size (n=6), the placental isoenzyme showed a significant agreement between the two methods: r = 0.999, slope = 0.98, and a -3.5% bias. Of the non-liver fractions reported by heat fractionation (n=13, ALP >100 U/L) eleven (85%) showed distinct qualitative bands in the intestinal lane on gel electrophoresis; however, quantitative values did not correlate between the two methods. Conclusion Our data support an agreement between the heat fractionation and gel electrophoresis methods for the quantitative determination of liver and placental alkaline phosphatase isoenzymes. Although there is an association between the two methods, the activity of the bone isoenzyme was underestimated by the gel electrophoresis method, likely due to saturation of the gel and densitometry scan because of elevated protein concentrations. The non-liver fractions were qualitatively identified as intestinal isoenzyme.


1986 ◽  
Vol 32 (7) ◽  
pp. 1264-1268 ◽  
Author(s):  
P K Sinha ◽  
A Bianchi-Bosisio ◽  
W Meyer-Sabellek ◽  
P G Righetti

Abstract This new method for fractionation of serum alkaline phosphatase isoenzymes is based on isoelectric focusing on a mixed-type polyacrylamide support containing an immobilized pH gradient with a superimposed carrier-ampholyte gradient. All known forms of alkaline phosphatase are separated in an Immobiline pH 3.5-6.0 gradient, the sample being applied into pockets cast on a pH 8.0 plateau. Sharp zymogram bands are obtained by substituting alkaline-stable 5-bromo-4-chloro-3-indoxyl phosphate and tetrazolium salts for the standard 1- and 2-naphthyl phosphate-diazonium salt combinations. After hydrolysis of the phosphate group by the alkaline phosphatase the indoxyl moieties reduce tetrazolium salts to nearly insoluble and nondiffusible formazan precipitates. Normal sera show an array of about 10 isobands isoelectric between pH 3.9 and pH 4.79. In Paget's disease, two sharp isobands with pls of 4.97 and 5.09 are seen. Placental alkaline phosphatase overlaps with the higher pl bands of normal serum; however, upon heat destruction of the latter, it shows four sharp bands with the following pl's: 4.59, 4.62, 4.67 and 4.73.


1976 ◽  
Vol 36 (2) ◽  
pp. 131-135 ◽  
Author(s):  
Inga Hägerstrand ◽  
Karin Lindholm ◽  
Ylva Lindroth

2020 ◽  
Vol 22 (Supplement_3) ◽  
pp. iii329-iii329
Author(s):  
Hiroki Yamada ◽  
Tomohiro Abiko ◽  
Hirokazu Fujiwara ◽  
Kazunari Yoshida ◽  
Hikaru Sasaki

Abstract INTRODUCTION Germ cell tumors in the central nervous system (CNS) typically arise either at suprasellar and/or pineal region, and occasionally at basal ganglia. We report a case of diagnostically challenging, recurrent germ cell tumor presented with diffuse intraaxial abnormality in and across the lower brainstem, which was diagnosed by the elevated placental alkaline phosphatase (PLAP) level in cerebrospinal fluid (CSF). CASE DESCRIPTION: A 28-year-old man had been treated by chemoradiotherapy at the previous hospital for bifocal suprasellar and pineal lesions with the provisional diagnosis of germinoma without histological confirmation. Three years later, he presented with progressive weakness of bilateral extremities for weeks. Magnetic resonance imaging showed a diffuse, bilaterally symmetric high intensity lesion on T2-weighted image with slight contrast enhancement across the ventral side of the medulla oblongata to the upper cervical spinal cord. Serum and CSF hCG, hCG-β, and AFP were all negative. Since the image findings were atypical for recurrent germ cell tumor, some kind of myelitis was initially suspected. Therefore, steroid pulse therapy was administered. However, the patient’s symptom was still gradually progressing. Then, the CSF PLAP turned out to be positive, indicating the recurrence of germinoma. Accordingly, platinum-based chemotherapy was administered, and the imaging findings, patient’s symptoms, and CSF PLAP began to improve. The patient is to be treated with radiotherapy following chemotherapy. CONCLUSION We report a rare case of CNS germ cell tumor that presented with diffuse intraaxial lesion in the lower brainstem in which examination of CSF PLAP was extremely useful.


Sign in / Sign up

Export Citation Format

Share Document