scholarly journals Tools for Label-free Peptide Quantification

2012 ◽  
Vol 12 (3) ◽  
pp. 549-556 ◽  
Author(s):  
Sven Nahnsen ◽  
Chris Bielow ◽  
Knut Reinert ◽  
Oliver Kohlbacher
2020 ◽  
Vol 79 ◽  
pp. 61-69
Author(s):  
Talita Mendes de Oliveira ◽  
José Thalles Jocelino Gomes de Lacerda ◽  
Giuseppe Gianini Figueiredo Leite ◽  
Meriellen Dias ◽  
Maria Anita Mendes ◽  
...  

2017 ◽  
Vol 35 (15_suppl) ◽  
pp. e12502-e12502
Author(s):  
Mohammad Muhsin Chisti ◽  
Juan Liu ◽  
Justin Frank Antoni Klamerus ◽  
Ishmael A. Jaiyesimi ◽  
Syeda Hina Batool ◽  
...  

e12502 Background: Her2Neu (H) antigen, expressed on 20% of Breast cancers, is an established target for antibody therapy with T. Immunohistochemistry is still the most widely used technique to detect h level which is time consuming and does not reveal any details of interaction between the molecules. We have developed a new innovative biosensor based novel technique to study real time interaction of h antigens with T using QCM Piezo-immunosensor. This quantitative label free peptide based assay can be used to characterize cell surface antigen, to study antigen- antibody interactions and obtain understanding of mechanisms of resistance. Methods: A label free and reagent free peptide mimotope capacitive biosensor is developed for T quantification based on non-Faradaic readout. The low sensitivity issue of capacitive biosensor was overcome with two innovations: peptide mimotope mixed SAM biointerface and dilution of the testing buffer. Signal amplification was achieved through dilution of the PBS buffer to tune Cdl to dominate the overall capacitance change upon target binding. After 1000 times dilution, limit of detection is lowered 500 times (0.22 µg/mL) and the sensitivity increased 20 times (0.04192 (µg/mL)-1). Results: Binding was very specific. Signal amplification strategy is practical. Further applied to planar electrode for optimizing sensing, response time in less than 1 minute. Conclusions: This is the first report of T detection using electrochemical method based on non-Faradaic impedance. h antigen density and interactions of antigens will help physicians to determine the clinical efficacy and resistance mechanisms to targeted antibodies like T and ado-Trastuzumab.For the first time, we have established a low cost, highly sensitive, fast, synthetic, QCM assay which could be used as a basis for developing a new generation of affinity-based Immunosensor assays. This real time capability and its simplicity of operation are highly suitable for multipurpose studies on living cells including cell immobilization, cytotoxicity of drugs, and the cell action mechanisms


2020 ◽  
Vol 1093 ◽  
pp. 123-130 ◽  
Author(s):  
Naveen Kumar ◽  
Sandeep Bhatia ◽  
Atul Kumar Pateriya ◽  
Richa Sood ◽  
S. Nagarajan ◽  
...  

2011 ◽  
Vol 4 (1) ◽  
Author(s):  
Mark K Titulaer ◽  
Dominique de Costa ◽  
Christoph Stingl ◽  
Lennard J Dekker ◽  
Peter AE Sillevis Smitt ◽  
...  
Keyword(s):  

Methods ◽  
2014 ◽  
Vol 68 (2) ◽  
pp. 331-337 ◽  
Author(s):  
Paulina D. Rakowska ◽  
Baptiste Lamarre ◽  
Maxim G. Ryadnov

2020 ◽  
Author(s):  
Nikolas Hundt

Abstract Single-molecule imaging has mostly been restricted to the use of fluorescence labelling as a contrast mechanism due to its superior ability to visualise molecules of interest on top of an overwhelming background of other molecules. Recently, interferometric scattering (iSCAT) microscopy has demonstrated the detection and imaging of single biomolecules based on light scattering without the need for fluorescent labels. Significant improvements in measurement sensitivity combined with a dependence of scattering signal on object size have led to the development of mass photometry, a technique that measures the mass of individual molecules and thereby determines mass distributions of biomolecule samples in solution. The experimental simplicity of mass photometry makes it a powerful tool to analyse biomolecular equilibria quantitatively with low sample consumption within minutes. When used for label-free imaging of reconstituted or cellular systems, the strict size-dependence of the iSCAT signal enables quantitative measurements of processes at size scales reaching from single-molecule observations during complex assembly up to mesoscopic dynamics of cellular components and extracellular protrusions. In this review, I would like to introduce the principles of this emerging imaging technology and discuss examples that show how mass-sensitive iSCAT can be used as a strong complement to other routine techniques in biochemistry.


2003 ◽  
Vol 773 ◽  
Author(s):  
Myung-Il Park ◽  
Jonging Hong ◽  
Dae Sung Yoon ◽  
Chong-Ook Park ◽  
Geunbae Im

AbstractThe large optical detection systems that are typically utilized at present may not be able to reach their full potential as portable analysis tools. Accurate, early, and fast diagnosis for many diseases requires the direct detection of biomolecules such as DNA, proteins, and cells. In this research, a glass microchip with integrated microelectrodes has been fabricated, and the performance of electrochemical impedance detection was investigated for the biomolecules. We have used label-free λ-DNA as a sample biomolecule. By changing the distance between microelectrodes, the significant difference between DW and the TE buffer solution is obtained from the impedance-frequency measurements. In addition, the comparison for the impedance magnitude of DW, the TE buffer, and λ-DNA at the same distance was analyzed.


Sign in / Sign up

Export Citation Format

Share Document