Limitations of 64-detector-row computed tomography coronary angiography: Calcium and motion but not short experience

2009 ◽  
Vol 50 (2) ◽  
pp. 174-180 ◽  
Author(s):  
H. Mir-Akbari ◽  
J. Ripsweden ◽  
J. Jensen ◽  
P. Pichler ◽  
C. Sylvén ◽  
...  

Background: Recently, 64-detector-row computed tomography coronary angiography (CTA) has been introduced for the noninvasive diagnosis of coronary artery disease. Purpose: To evaluate the diagnostic capacity and limitations of a newly established CTA service. Material and Methods: In 101 outpatients with suspected coronary artery disease, 64-detector-row CTA (VCT Lightspeed 64; GE Healthcare, Milwaukee, Wisc., USA) was performed before invasive coronary angiography (ICA). The presence of >50% diameter coronary stenosis on CTA was rated by two radiologists recently trained in CTA, and separately by an experienced colleague. Diagnostic performance of CTA was calculated on segment, vessel, and patient levels, using ICA as a reference. Segments with a proximal reference diameter <2 mm or with stents were not analyzed. Results: In 51 of 101 patients and 121 of 1280 segments, ICA detected coronary stenosis. In 274 of 1280 (21%) segments, CTA had non-diagnostic image quality, the main reasons being severe calcifications (49%), motion artifacts associated with high or irregular heart rate (45%), and low contrast opacification (14%). Significantly more women (43%) had non-diagnostic scans compared to men (20%). A heart rate above 60 beats per minute was associated with significantly more non-diagnostic patients (38% vs. 18%). In the 1006 diagnostic segments, CTA had a sensitivity of 78%, specificity of 95%, positive predictive value (PPV) of 54%, and negative predictive value (NPV) of 98% for detecting significant coronary stenosis. In 29 patients, CTA was non-diagnostic. In the remaining 72 patients, sensitivity was 100%, specificity 65%, PPV 79%, and NPV 100%. The use of a more experienced CTA reader did not improve diagnostic performance. Conclusion: CTA had a very high negative predictive value, but the number of non-diagnostic scans was high, especially in women. The main limitations were motion artifacts and vessel calcifications, while short experience in CTA did not influence the interpretation.

2010 ◽  
Vol 4 ◽  
pp. CMC.S3864 ◽  
Author(s):  
M. Wehrschuetz ◽  
E. Wehrschuetz ◽  
H. Schuchlenz ◽  
G. Schaffler

Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subsequent introduction of 64-slice scanners promised excellent and fast results for coronary artery studies. This prompted us to evaluate the diagnostic accuracy, sensitivity, specificity, and the negative und positive predictive value of 64-slice MSCT in the detection of haemodynamically significant coronary artery stenoses. Thirty-seven consecutive subjects with suspected coronary artery disease were evaluated with MSCT angiography and the results compared with QCA. All vessels were considered for the assessment of significant coronary artery stenosis (diameter reduction ≥ 50%). Thirteen patients (35%) were identified as having significant coronary artery stenoses on QCA with 6.3% (35/555) affected segments. None of the coronary segments were excluded from analysis. Overall sensitivity for classifying stenoses of 64-slice MSCT was 69%, specificity was 92%, positive predictive value was 38% and negative predictive value was 98%. The interobserver variability for detection of significant lesions had a κ-value of 0.43. Sixty-four-slice MSCT offers the diagnostic potential to detect coronary artery disease, to quantify haemodynamically significant coronary artery stenoses and to avoid unnecessary invasive coronary artery examinations.


Sign in / Sign up

Export Citation Format

Share Document