Determination of Pantoprazole in Pharmaceutical Formulations and Human Plasma by Square‐Wave Voltammetry

2005 ◽  
Vol 38 (9) ◽  
pp. 1389-1404 ◽  
Author(s):  
Sacide Altınöz ◽  
Incilay Süslü
Author(s):  
İsmail Murat Palabıyık ◽  
Aysegul Dogan ◽  
İncilay Süslü

Background: Hypertension is one of the most important health problems in the world and irbesartan and amlodipine are used in combination in various dosages for the treatment of high blood pressure. Objective: The aim of this study is to develop a fast, easy, sensitive, accurate, and precise square-wave voltammetry method for simultaneous determination of irbesartan and amlodipine besylate from pharmaceutical formulations at a hanging mercury drop electrode. Methods: In the applied method, since both active substances gave a peak at different potentials, no interference occurred between them. In optimization studies Britton-Robinson buffer of pH 8.0 was chosen, in which the most appropriate peak shape and maximum peak current were observed. At the same time, as a result of instrumental parameter optimization to obtain reproducible results, 6 mV for scan increment, 30 mV for pulse amplitude, and 50 Hz for frequency were found suitable. Results: As a result of the calibration studies of the optimized method, linear working ranges were determined as 1.00-13.08 µg mL-1 for irbesartan and 5.83-16.51 µg mL-1 for amlodipine besylate. Limit of detection and limit of quantitation values were respectively calculated as 0.63 and 1.00 µg mL-1 for irbesartan and 0.50 and 1.98 µg mL-1 for amlodipine besylate. The results of precision values (RSD) ranged from 0.67% to 2.31% for irbesartan and 0.65% to 1.49% for amlodipine besylate. Accuracy values were calculated as -0.15% to 1.63% for irbesartan and -0.07% to 3.78% for amlodipine besylate. The results obtained from the recovery studies ranged from 101.05% to 102.78% and from 98.88% to 102.20% for amlodipine besylate and irbesartan, respectively. Conclusion: After the validation studies of the developed method were carried out, it was successfully applied to pharmaceutical formulations containing these active substances.


Química Nova ◽  
2010 ◽  
Vol 33 (4) ◽  
pp. 964-967 ◽  
Author(s):  
Carolina V. Uliana ◽  
Hideko Yamanaka ◽  
Gustavo S. Garbellini ◽  
Giancarlo R. Salazar-Banda

2012 ◽  
Vol 48 (4) ◽  
pp. 639-649 ◽  
Author(s):  
Kellen Heloizy Garcia Freitas ◽  
Orlando Fatibello-Filho ◽  
Ivanildo Luiz de Mattos

A carbon composite electrode modified with copper (II) phosphate immobilized in a polyester resin (Cu3(PO4)2-Poly) for the determination of rutin in pharmaceutical samples by square-wave voltammetry is described herein. The modified electrode allows the determination of rutin at a potential (0.20 V vs. Ag/AgCl (3.0 mol L-1 KCl)) lower than that observed at an unmodified electrode. The peak current was found to be linear to the rutin concentration in the range from 9.9 × 10-8 to 2.5 × 10-6 mol L-1, with a detection limit of 1.2×10-8 mol L-1. The response of the electrode was stable, with no variation in baseline levels within several hours of continuous operation. The surface morphology of the modified electrode was characterized by scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) system. The results obtained are precise and accurate. In addition, these results are in agreement with those obtained by the chromatographic method at a 95% confidence level.


2016 ◽  
Vol 129 ◽  
pp. 205-212 ◽  
Author(s):  
Adrian Marcelo Granero ◽  
Gastón Darío Pierini ◽  
Sebastián Noel Robledo ◽  
María Susana Di Nezio ◽  
Héctor Fernández ◽  
...  