cadmium zinc
Recently Published Documents


TOTAL DOCUMENTS

890
(FIVE YEARS 116)

H-INDEX

63
(FIVE YEARS 5)

CrystEngComm ◽  
2022 ◽  
Author(s):  
Wanzhong Li ◽  
Jian Sun ◽  
Chong Deng

Cadmium Zinc Telluride (CdZnTe) single crystals have been widely ultilized in various photoelectron devices such as radiation detectors and solar cells. Different types of ordered phases have also been investigated...


Studies have shown that cigarette smoking affects the accumulation of some heavy metals in certain tissues and metabolism of essential elements. The aim of the study was to determine the differences in the concentrations of cadmium in the blood and urine and zinc in the urine of smokers and ex-smokers in relation to non-smokers, and to determine the possible influence of cadmium concentration on zinc excretion as an essential element. The study included 106 subjects. Subjects were regular smokers (n=51), ex-smokers (n=38) and non-smokers (n=17). Atomic absorption spectrophotometry (AAS) with an electrothermal atomizer was used to determine cadmium. Zinc was determined by AAS with a flame atomizer. There was a significant difference in the values of cadmium in the blood between the groups: smokers and non-smokers (p<0.001), smokers and ex-smokers (p <0.001), and between ex-smokers and non-smokers (p = 0.045). There is a significant positive and strong correlation in the level of zinc and cadmium in urine per gram of creatinine, and as the level of cadmium increases, the level of zinc also increases (rho=0.781; p=0.001). The data indicate that cigarette smoking has been shown to be a factor that can increase cadmium levels to an extent that will significantly increase zinc excretion, or its increased loss.


Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2268
Author(s):  
Maria Normand Hansen ◽  
Christian Haarmark ◽  
Bent Kristensen ◽  
Bo Zerahn

The aim of the present study was to test an individualised dose without compromising the ease of analysing data when performing equilibrium radionuclide angiography (ERNA) using cadmium–zinc–telluride (CZT) SPECT. From March 2018 to January 2019, 1650 patients referred for ERNA received either an individualised dose of 99mTc-labeled human serum albumin (HSA) according to their age, sex, height, and weight (n = 1567), or a standard dose of 550 MBq (n = 83). The target count rate (CRT) was reduced every two months from 2.7 to 1.0 kcps. A final test with a CRT of 1.7 kcps was run for three months to test whether an agreement within 2% points for the determination of LVEF, on the basis of only two analyses, was obtainable in at least 95% of acquisitions. All the included ERNAs were performed on a dedicated cardiac CZT SPECT camera. When using the algorithm for an individualised dose, we found that agreement between the measured and predicted count rate was 80%. With a CRT of 1.7 kcps, the need for more than two analyses to obtain sufficient agreement for LVEF was 4.9%. Furthermore, this resulted in a mean dose reduction from 550 to 258 MBq. Patients’ weight, height, sex, and age can, therefore, be used for individualising a tracer dose while reducing the mean dose.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Tomohiko Yamane ◽  
Masafumi Takahashi ◽  
Yohji Matsusaka ◽  
Kenji Fukushima ◽  
Akira Seto ◽  
...  

AbstractThe aim of this study was to evaluate the quantitative values of short-time scan (STS) of metastatic lesions compared with a standard scan (SS) when acquired by whole-body bone SPECT/CT with cadmium–zinc–telluride (CZT) detectors. We retrospectively reviewed 13 patients with bone metastases from prostate cancer, who underwent SPECT/CT performed on whole-body CZT gamma cameras. STSs were obtained using 75, 50, 25, 10, and 5% of the list-mode data for SS, respectively. Regions of interest (ROIs) were set on the increased uptake areas diagnosed as metastases. Intraclass correlation coefficients (ICCs) of standardized uptake values (SUVs) for the ROIs were calculated between the SS and each STS, and ICC ≥ 0.8 was set as a perfect correlation. Moreover, the repeatability coefficient (RC) was calculated, and RC ≤ 20% was defined as acceptable. A total of 152 metastatic lesions were included in the analysis. The ICCs between the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 0.999, 0.997, 0.994, 0.983, and 0.955, respectively. The RCs of the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 7.9, 12.4, 19.8, 30.8, and 41.3%, respectively. When evaluating the quality of CZT bone SPECT/CT acquired by a standard protocol, 25%-STS may provide adequate quantitative values.


Author(s):  
Behrooz Jannat ◽  
Sara Mirshamsi ◽  
Naficeh Sadeghi ◽  
Mohammad Reza Oveisi ◽  
Mannan Hajimahmoodi

Pickled cucumber is frequently consumed by Iranians. According to the production process, there are two forms of pickled cucumber including industrial and fermentative. There is not an appropriate monitoring system available for the production of the latter form; therefore, high levels of heavy metals might be present in this type of pickled cucumber. Accordingly, so the levels of cadmium, zinc, lead and copper were measured in fermentative pickled cucumbers obtained from the Tehran market via the polarographic method. Polarography is a subclass of voltammetry where the working electrode is a dropping mercury electrode (DME) or a static mercury drop electrode (SMDE), which are useful for their wide cathodic ranges and renewable surfaces. Fifty different samples of pickled cucumbers were purchased from the market. Of each sample, dry ashes were produced. Measurement was repeated three times and the acquired data was then analyzed. The mean levels of zinc and copper in the evaluated samples were significantly lower than the standard limits respectively presented by the EOS and Codex (P value<0.001) while the mean level of cadmium and lead was slightly higher than the standard limit established by Codex with no significant differences observed (P values=0.450 and 0.246, respectively).


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Valeria Cantoni ◽  
Roberta Green ◽  
Carlo Ricciardi ◽  
Roberta Assante ◽  
Leandro Donisi ◽  
...  

We compared the prognostic value of myocardial perfusion imaging (MPI) by conventional- (C-) single-photon emission computed tomography (SPECT) and cadmium-zinc-telluride- (CZT-) SPECT in a cohort of patients with suspected or known coronary artery disease (CAD) using machine learning (ML) algorithms. A total of 453 consecutive patients underwent stress MPI by both C-SPECT and CZT-SPECT. The outcome was a composite end point of all-cause death, cardiac death, nonfatal myocardial infarction, or coronary revascularization procedures whichever occurred first. ML analysis performed through the implementation of random forest (RF) and k -nearest neighbors (KNN) algorithms proved that CZT-SPECT has greater accuracy than C-SPECT in detecting CAD. For both algorithms, the sensitivity of CZT-SPECT (96% for RF and 60% for KNN) was greater than that of C-SPECT (88% for RF and 53% for KNN). A preliminary univariate analysis was performed through Mann-Whitney tests separately on the features of each camera in order to understand which ones could distinguish patients who will experience an adverse event from those who will not. Then, a machine learning analysis was performed by using Matlab (v. 2019b). Tree, KNN, support vector machine (SVM), Naïve Bayes, and RF were implemented twice: first, the analysis was performed on the as-is dataset; then, since the dataset was imbalanced (patients experiencing an adverse event were lower than the others), the analysis was performed again after balancing the classes through the Synthetic Minority Oversampling Technique. According to KNN and SVM with and without balancing the classes, the accuracy ( p value = 0.02 and p value = 0.01) and recall ( p value = 0.001 and p value = 0.03) of the CZT-SPECT were greater than those obtained by C-SPECT in a statistically significant way. ML approach showed that although the prognostic value of stress MPI by C-SPECT and CZT-SPECT is comparable, CZT-SPECT seems to have higher accuracy and recall.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Ruyi Zhang ◽  
Miao Wang ◽  
Yaqian Zhou ◽  
Shen Wang ◽  
Yiming Shen ◽  
...  

Abstract Background The digital cadmium–zinc–telluride (CZT)-based SPECT system has many advantages, including better spatial and energy resolution. However, the impacts of different acquisition and reconstruction parameters on CZT SPECT quantification might still need to be validated. This study aimed to evaluate the impacts of acquisition parameters (the main energy window and acquisition time per frame) and reconstruction parameters (the number of iterations, subsets in iterative reconstruction, post-filter, and image correction methods) on the technetium quantification of CZT SPECT/CT. Methods A phantom (PET NEMA/IEC image quality, USA) was filled with four target-to-background (T/B) ratios (32:1, 16:1, 8:1, and 4:1) of technetium. Mean uptake values (the calculated mean concentrations for spheres) were measured to evaluate the recovery coefficient (RC) changes under different acquisition and reconstruction parameters. The corresponding standard deviations of mean uptake values were also measured to evaluate the quantification error. Image quality was evaluated using the National Electrical Manufacturers Association (NEMA) NU 2–2012 standard. Results For all T/B ratios, significant correlations were found between iterations and RCs (r = 0.62–0.96 for 1–35 iterations, r = 0.94–0.99 for 35–90 iterations) as well as between the full width at half maximum (FWHM) of the Gaussian filter and RCs (r = − 0.86 to − 1.00, all P values < 0.05). The regression coefficients of 1–35 iterations were higher than those of 35–90 iterations (0.51–1.60 vs. 0.02–0.19). RCs calculated with AC (attenuation correction) + SC (scatter correction) + RR (resolution recovery correction) combination were more accurate (53.82–106.70%) than those calculated with other combinations (all P values < 0.05). No significant statistical differences (all P values > 0.05) were found between the 15% and 20% energy windows except for the 32:1 T/B ratio (P value = 0.023) or between the 10 s/frame and 120 s/frame acquisition times except for the 4:1 T/B ratio (P value = 0.015) in terms of RCs. Conclusions CZT-SPECT/CT of technetium resulted in good quantification accuracy. The favourable acquisition parameters might be a 15% energy window and 40 s/frame of acquisition time. The favourable reconstruction parameters might be 35 iterations, 20 subsets, the AC + SC + RR correction combination, and no filter.


Sign in / Sign up

Export Citation Format

Share Document