Evaluation of effective dose conversion coefficients for Korean adults during medical x-ray examinations up to 150 keV through comparison with ICRP Publication 74 and ICRP Publication 116

2014 ◽  
Vol 34 (1) ◽  
pp. 191-199 ◽  
Author(s):  
Mihyun Keum ◽  
Jae Hong Park ◽  
Sung Ho Park ◽  
Seung Do Ahn
2019 ◽  
Vol 12 (3) ◽  
pp. 120-132
Author(s):  
V. Yu. Golikov ◽  
L. A. Chipiga ◽  
A. V. Vodovatov ◽  
S. S. Sarycheva

The current study was aimed at the justification and proposal of the supplements and corrections that are planned for the implementation in the updated version of the Methodical guidelines “Control of the effective doses of the patients from the X-ray examinations” (MU 2.6.1.2944-11). This study included estimation and/ or update of the values of the conversion coefficients from measurable dose characteristics (entrance-surface dose, dose-area product) to the effective dose for various X-ray examinations. Estimation of the updated conversion coefficients was based both on the home analytical and experimental studies based on the modern protocols of the X-ray examinations, and the results of the published data. Updated values of the conversion coefficients were presented for: fluoroscopic examinations of the gastro-intestinal tract with barium media for adult and pediatric patients; interventional examinations of the adult patients; computed tomography examinations for adult and pediatric patients; dental intraoral examinations. For the first time, the methods of the estimation of the effective dose and corresponding conversion coefficients were presented for: computed tomography of the extremities, whole body, scan of several anatomic regions; angiographic examinations of the heart vessels of the pediatric patients of different age categories; slot-scanning X-ray examinations; bone densitometry.


2005 ◽  
Vol 44 (05) ◽  
pp. 119-130 ◽  
Author(s):  
P. Schnell-Inderst ◽  
D. Noßke ◽  
M. Weiss ◽  
A. Stamm-Meyer ◽  
G. Brix ◽  
...  

Summary:The aim of this study was to estimate both the frequency and effective dose of nuclear medicine procedures performed in Germany between 1996 and 2000 for different subgroups of patients. Methods: Electronically archived data from 14 hospitals and 10 private practices were restored and statistically analyzed. The effective dose per examination was calculated according to ICRP publication 80 using the tissue weighting factors given in ICRP publication 60. Based on the data collected, statistical parameters were computed to characterize the frequency and effective dose of the various nuclear medicine procedures. Results: In total, 604,771 nuclear medicine procedures performed in 433,709 patients were analyzed. On average, 1.4 examinations were carried out per patient and year. The median effective dose was 1.7 [5.-95. percentile; mean: 0.4–8.5; 2.9] mSv per examination and 2.3 [0.5–11.2; 3.5] mSv per patient. Interestingly, the mean effective dose per examination, but not the number of examinations per year increased with the age of the patients. Most frequent were examinations of the thyroid (36.7%), the skeleton (27.1%) and the cardiovascular system (11.1%), which were associated with a median effective dose of 0.5 [0.5–1.1; 0.7] mSv, 3.4 [2.9–5.1; 3.6] mSv and 7.3 [3.2–21.0; 9.5] mSv, respectively. Over the five-year period examined, the total annual number of PET procedures (222.3%) as well as of examinations of thyroid (24.5%), skeleton (17.9%), and the cardiovascular system (14.9%) increased markedly, whereas a decrease was observed for brain (-39.3%), lung (-20.2%) and renal (-15.0%) scans. Conclusion: The age- and gender-specific data presented in this study provide detailed public health information on both the current status and recent trends in the practice of diagnostic nuclear medicine examinations.


2014 ◽  
Vol 35 (1) ◽  
pp. 75-86 ◽  
Author(s):  
Andy K Ma ◽  
Mohammed Adel Hussein ◽  
Khalid Mohammed Altaher ◽  
Khalid Yousif Farid ◽  
Mamun Amer ◽  
...  

2010 ◽  
Vol 51 (3) ◽  
pp. 260-270 ◽  
Author(s):  
Peter Björkdahl ◽  
Ulf Nyman

Background: Concern has been raised regarding the mounting collective radiation doses from computed tomography (CT), increasing the risk of radiation-induced cancers in exposed populations. Purpose: To compare radiation dose and image quality in a chest phantom and in patients for the diagnosis of pulmonary embolism (PE) at 100 and 120 peak kilovoltage (kVp) using 16-multichannel detector computed tomography (MDCT). Material and Methods: A 20-ml syringe containing 12 mg I/ml was scanned in a chest phantom at 100/120 kVp and 25 milliampere seconds (mAs). Consecutive patients underwent 100 kVp ( n = 50) and 120 kVp ( n = 50) 16-MDCT using a “quality reference” effective mAs of 100, 300 mg I/kg, and a 12-s injection duration. Attenuation (CT number), image noise (1 standard deviation), and contrast-to-noise ratio (CNR; fresh clot = 70 HU) of the contrast medium syringe and pulmonary arteries were evaluated on 3-mm-thick slices. Subjective image quality was assessed. Computed tomography dose index (CTDIvol) and dose–length product (DLP) were presented by the CT software, and effective dose was estimated. Results: Mean values in the chest phantom and patients changed as follows when X-ray tube potential decreased from 120 to 100 kVp: attenuation +23% and +40%, noise +38% and +48%, CNR −6% and 0%, and CTDIvol −38% and −40%, respectively. Mean DLP and effective dose in the patients decreased by 42% and 45%, respectively. Subjective image quality was excellent or adequate in 49/48 patients at 100/120 kVp. No patient with a negative CT had any thromboembolism diagnosed during 3-month follow-up. Conclusion: By reducing X-ray tube potential from 120 to 100 kVp, while keeping all other scanning parameters unchanged, the radiation dose to the patient may be almost halved without deterioration of diagnostic quality, which may be of particular benefit in young individuals.


1973 ◽  
Vol 28 (10) ◽  
pp. 1635-1641 ◽  
Author(s):  
A. G. de Pinho ◽  
M. Weksler

The X-ray spectra resulting from the internal conversion of electric quadrupole transitions following the alpha decay of Th230 and Ra226 were analysed with a Si (Li) spectrometer. From the knowledge of the Coster-Kronig and fluorescence yields, the internal conversion coefficients of the E2 transitions from the first excited states in Ra226 and Rn222 could be deduced. Results are in good agreement with theoretical values.


2015 ◽  
Vol 7 (5) ◽  
Author(s):  
Akbar Aliasgharzadeh ◽  
Ehsan Mihandoost ◽  
Mahboubeh Masoumbeigi ◽  
Morteza Salimian ◽  
Mehran Mohseni

Sign in / Sign up

Export Citation Format

Share Document