Precision calibration method for binocular vision measurement systems based on arbitrary translations and 3D-connection information

2016 ◽  
Vol 27 (10) ◽  
pp. 105009 ◽  
Author(s):  
Jinghao Yang ◽  
Zhenyuan Jia ◽  
Wei Liu ◽  
Chaonan Fan ◽  
Pengtao Xu ◽  
...  
IEEE Access ◽  
2021 ◽  
Vol 9 ◽  
pp. 44354-44362
Author(s):  
Mingwei Shao ◽  
Pan Wang ◽  
Yanjun Wang

2012 ◽  
Vol 220-223 ◽  
pp. 1311-1314
Author(s):  
Chen Dong ◽  
Shu Guang Dai

As the rapid progress and development of DSP technology, a new way to solve the video signal processing was accepted. At present, binocular measurement instrument are mostly based on image capture card and PC on the market, expensive and bulky. For this problem, binocular vision measurement system based on DSP has been used. The design of elementary program structure about video processing which based on DSP/BIOS was finished and verified for its real-time. The results of the experiment show that the driver can be well used in the system.


Author(s):  
Mingchi Feng ◽  
Xiang Jia ◽  
Jingshu Wang ◽  
Song Feng ◽  
Taixiong Zheng

Multi-cameras system is widely applied in 3D computer vision especially when multiple cameras are distributed on both sides of the measured object. The calibration methods of multi-cameras system are critical to the accuracy of vision measurement and the key is to find an appropriate calibration target. In this paper, a high-precision camera calibration method for multi-cameras system based on transparent glass checkerboard and ray tracing is described, which is used to calibrate multiple cameras distributed on both sides of the glass checkerboard. Firstly, the intrinsic parameters of each camera is obtained by Zhang’s calibration method. Then, multiple cameras capture several images from the front and back of the glass checkerboard with different orientations, and all images contain distinct grid corners. As the cameras on one side are not affected by the refraction of glass checkerboard, extrinsic parameters can be directly calculated. However, the cameras on another side are influenced by the refraction of glass checkerboard, and the direct use of projection model will produce calibration error. A multi-cameras calibration method using refractive projection model and ray tracing is developed to eliminate this error. Furthermore, both synthetic and real data are employed to validate the proposed approach. The experimental results of refractive calibration show that the error of the 3D reconstruction is smaller than 0.2 mm, the relative errors of both rotation and translation are less than 0.014%, and the mean and standard deviation of reprojection error of 4-cameras system are 0.00007 and 0.4543 pixel. The proposed method is flexible, high accurate, and simple to carry out.


Sign in / Sign up

Export Citation Format

Share Document