The noise navigator for MRI-guided radiotherapy: an independent method to detect physiological motion

2020 ◽  
Vol 65 (12) ◽  
pp. 12NT01
Author(s):  
R J M Navest ◽  
S Mandija ◽  
S E Zijlema ◽  
B Stemkens ◽  
A Andreychenko ◽  
...  
2004 ◽  
Vol 171 (4S) ◽  
pp. 223-223
Author(s):  
Jonathan A. Coleman ◽  
Robert C. Susil ◽  
Axel Krieger ◽  
Peter L. Choyke ◽  
Betty Wise ◽  
...  

2020 ◽  
pp. 25-31
Author(s):  
M. L. Mazo ◽  
O. E. Jacobs ◽  
O. S. Puchkova ◽  
M. V. Feldsherov ◽  
E. V. Kondratyev

The rate of detection of breast cancer by MRI, while other methods of radiological diagnosis are not sufficiently informative, ranges from 5.2 to 26.3 per cent. Suspicious breast tumors of category BI-RADS 4, 5 show morphological image-guided biopsy verification, in particular MRI with contrast. Purpose. To show the possibilities and features of carrying out MRI-guided vacuum breast biopsy, including after aesthetic breast augmentation. Material and methods. A comprehensive X-ray, ultrasound and MRI examination of 54 women aged between 28 and 70 years with different breast tumors was conducted. Of these, five were detected only by breast MRI with contrast, and were morphologically verified by MRI-guided vacuum aspiration biopsy. Results. 14 of the 54 patients with breast mass were diagnosed with breast cancer and 26 were diagnosed with benign diseases. The effectiveness of comprehensive examination and low-invasive high-tech MRI-guided procedures in early refined screening for breast cancer, including after aesthetic breast augmentation, has been demonstrated. MRI-guided vacuum-assisted breast biopsy is a fast, safe and accurate diagnostic method of morphological verification of suspicious breast tumors that do not have X-ray and ultrasound.


Author(s):  
Johannes Mayer ◽  
Thomas-Heinrich Wurster ◽  
Tobias Schaeffter ◽  
Ulf Landmesser ◽  
Andreas Morguet ◽  
...  

Abstract Background Cardiac PET has recently found novel applications in coronary atherosclerosis imaging using [18F]NaF as a radiotracer, highlighting vulnerable plaques. However, the resulting uptakes are relatively small, and cardiac motion and respiration-induced movement of the heart can impair the reconstructed images due to motion blurring and attenuation correction mismatches. This study aimed to apply an MR-based motion compensation framework to [18F]NaF data yielding high-resolution motion-compensated PET and MR images. Methods Free-breathing 3-dimensional Dixon MR data were acquired, retrospectively binned into multiple respiratory and cardiac motion states, and split into fat and water fraction using a model-based reconstruction framework. From the dynamic MR reconstructions, both a non-rigid cardiorespiratory motion model and a motion-resolved attenuation map were generated and applied to the PET data to improve image quality. The approach was tested in 10 patients and focal tracer hotspots were evaluated concerning their target-to-background ratio, contrast-to-background ratio, and their diameter. Results MR-based motion models were successfully applied to compensate for physiological motion in both PET and MR. Target-to-background ratios of identified plaques improved by 7 ± 7%, contrast-to-background ratios by 26 ± 38%, and the plaque diameter decreased by −22 ± 18%. MR-based dynamic attenuation correction strongly reduced attenuation correction artefacts and was not affected by stent-related signal voids in the underlying MR reconstructions. Conclusions The MR-based motion correction framework presented here can improve the target-to-background, contrast-to-background, and width of focal tracer hotspots in the coronary system. The dynamic attenuation correction could effectively mitigate the risk of attenuation correction artefacts in the coronaries at the lung-soft tissue boundary. In combination, this could enable a more reproducible and reliable plaque localisation.


Sign in / Sign up

Export Citation Format

Share Document