scholarly journals New criteria for proficiency assessment of clinical laboratories by interlaboratory comparisons

2018 ◽  
Vol 1065 ◽  
pp. 132003
Author(s):  
Diogo José da Silva Jerônimo ◽  
Elisabeth Costa Monteiro
Author(s):  
J. N. Meador ◽  
C. N. Sun ◽  
H. J. White

The electron microscope is being utilized more and more in clinical laboratories for pathologic diagnosis. One of the major problems in the utilization of the electron microscope for diagnostic purposes is the time element involved. Recent experimentation with rapid embedding has shown that this long phase of the process can be greatly shortened. In rush cases the making of projection slides can be eliminated by taking dark field electron micrographs which show up as a positive ready for use. The major limiting factor for use of dark field micrographs is resolution. However, for conference purposes electron micrographs are usually taken at 2.500X to 8.000X. At these low magnifications the resolution obtained is quite acceptable.


2008 ◽  
Vol 7 (3) ◽  
pp. 1-8
Author(s):  
DENISE NAPOLI
Keyword(s):  

2010 ◽  
Vol 38 (10) ◽  
pp. 27
Author(s):  
MICHELE G. SULLIVAN
Keyword(s):  

2010 ◽  
Vol 40 (13) ◽  
pp. 1-43
Author(s):  
MICHELE G. SULLIVAN
Keyword(s):  

1974 ◽  
Vol 13 (03) ◽  
pp. 151-158 ◽  
Author(s):  
D. A. B. Lindbebo ◽  
Fr. R. Watson

Recent studies suggest the determinations of clinical laboratories must be made more precise than at present. This paper presents a means of examining benefits of improvement in precision. To do this we use a mathematical model of the effect upon the diagnostic process of imprecision in measurements and the influence upon these two of Importance of Diagnosis and Prevalence of Disease. The interaction of these effects is grossly non-linear. There is therefore no proper intuitive answer to questions involving these matters. The effects can always, however, be calculated.Including a great many assumptions the modeling suggests that improvements in precision of any determination ought probably to be made in hospital rather than screening laboratories, unless Importance of Diagnosis is extremely high.


1991 ◽  
Vol 65 (02) ◽  
pp. 160-164 ◽  
Author(s):  
Marina Poggio ◽  
Armando Tripodi ◽  
Guglielmo Mariani ◽  
Pier Mannuccio Mannucci ◽  

SummaryBeing a putative predictor of ischemic heart disease, the measurement of factor VII (FVTI) coagulant activity will be presumably requested to clinical laboratories with increasing frequency. To assess the influence on FVII assays of different thromboplastins and FVII-deficient plasmas we compared performances of all possible combinations of 5 thromboplastins and 6 deficient plasmas. The reproducibility of the clotting times of the dose-response curves for human and rabbit thromboplastins were acceptable (CV lower than 7%), whereas bovine thromboplastin had a higher CV. Reproducibility was very similar for all deficient plasmas when they were used in combination with a given thromboplastin. Responsiveness of the dose-response curve did not depend on the deficient plasma but rather on the thromboplastin: one rabbit thromboplastin was the least responsive, the bovine thromboplastin the most responsive, the human and the remaining two rabbit thromboplastins had intermediate responsiveness. Assay sensitivity to cold-activated FVII varied according to the thromboplastin: the bovine thromboplastin was the most sensitive, the human thromboplastin the least sensitive, of the three rabbit thromboplastins two were relatively sensitive, one was almost insensitive. In conclusion, our results indicate that thromboplastin rather than deficient plasma is the crucial factor in the standardization of FVII assay.