scholarly journals A Non-Lethal Electric Shock Generator with Wireless Control Function

2020 ◽  
Vol 1507 ◽  
pp. 072028
Author(s):  
Chunxia Yang ◽  
Gang Wan ◽  
Jian Liu ◽  
Wenxuan Zhang ◽  
Hui Tian ◽  
...  
2013 ◽  
Vol 397-400 ◽  
pp. 2019-2023
Author(s):  
Cun Feng Kang ◽  
Chun Zang

Developed a pair of Bluetooth master and slave modules with embedded microcontroller, based on wireless communication technology and automatic control theory, which could be simply applied into common equipments to achieve digital I/O communication. The pair of modules separately linked the control panel and PLC, and accomplish corresponding motion control through wireless data communication. Then the master-slave modules were applied to a three-dimensional warehouse model as a case to verify their wireless control function. This research successfully solves the bondage of digital communication with cables in previous industrial field.


1968 ◽  
Vol 73 (3, Pt.1) ◽  
pp. 268-272 ◽  
Author(s):  
Robert D. Hare

1967 ◽  
Vol 28 (1) ◽  
pp. 132-137 ◽  
Author(s):  
Robert D. Myers ◽  
R. Bruce Holman

2017 ◽  
Vol 137 (4) ◽  
pp. 229-235
Author(s):  
Yoshinori Taka ◽  
Akimasa Hirata ◽  
Kenichi Yamazaki ◽  
Osamu Fujiwara

Vestnik MEI ◽  
2020 ◽  
Vol 6 (6) ◽  
pp. 39-45
Author(s):  
Ruslan K. Borisov ◽  
◽  
Sergey S. Zhulikov ◽  
Sergey I. Khrenov ◽  
Yuliya S. Turchaninova ◽  
...  

An objective to develop a labor protection engineering stand was set forth as part of the research and development work "Carrying out theoretical and experimental investigations and development of stands for demonstrating the danger of electric shock at a training ground" for visually demonstrating the danger of injuring a person by touch and step voltages in 3…35 kV medium voltage electric networks. The technical solutions for practically implementing the stand were adopted based on an analysis of regulatory documents, conditions under which dangerous touch and step voltages occur, the most typical human injury cases, and calculation results. Specialists of the National Research University Moscow Power Engineering Institute Department of High Voltage Engineering and Electrophysics, working jointly with specialists of PJSC Rosseti Moscow Region have developed, manufactured, tested, and put into operation a stand for demonstrating human injury by the touch and step voltages when a 10 kV wire falls on the ground, on a car, and when a fault of a live wire on the overhead line support occurs. With the stand having been put in use at the PJSC Rosseti Moscow Region Training Center Ground, this will allow the staff to form a clear understanding of the electric shock danger, to focus on the effects caused by voltage and current, and thereby significantly reduce electrical injuries.