detection threshold
Recently Published Documents


TOTAL DOCUMENTS

1193
(FIVE YEARS 365)

H-INDEX

51
(FIVE YEARS 8)

2022 ◽  
Vol 14 (2) ◽  
pp. 403
Author(s):  
Chongdi Duan ◽  
Yu Li ◽  
Weiwei Wang ◽  
Jianguo Li

With the rapid development of cooperative detection technology, target fusion detection with regard of LEO satellites can be realized by means of their diverse observation configurations. However, the existing constant false alarm ratio (CFAR) detection research rarely involves the space-based target fusion detection theory. In this paper, a novel multi-source fusion detection method based on LEO satellites is presented. Firstly, the pre-compensation function is constructed by employing the range and Doppler history of the cell where the antenna beam center is pointed. As a result, not only is the Doppler band broadening problem caused by the high-speed movement of the satellite platform, but the Doppler frequency rate (DFR) offset issue resulted from different observation configurations are alleviated synchronously. Then, the theoretical upper and lower limits of DFR are designed to achieve the effective clutter suppression and the accurate target echo fusion. Finally, the CFAR detection threshold based on the exponential weighted likelihood ratio is derived, which effectively increases the contrast ratio between the target cell and other background cells, and thus to provide an effective multi-source fusion detection method for LEO-based satellite constellation. Simulation results verify the effectiveness of the proposed algorithm.


Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 631
Author(s):  
Josip Lorincz ◽  
Ivana Ramljak ◽  
Dinko Begušić

Due to the capability of the effective usage of the radio frequency spectrum, a concept known as cognitive radio has undergone a broad exploitation in real implementations. Spectrum sensing as a core function of the cognitive radio enables secondary users to monitor the frequency band of primary users and its exploitation in periods of availability. In this work, the efficiency of spectrum sensing performed with the energy detection method realized through the square-law combining of the received signals at secondary users has been analyzed. Performance evaluation of the energy detection method was done for the wireless system in which signal transmission is based on Multiple-Input Multiple-Output—Orthogonal Frequency Division Multiplexing. Although such transmission brings different advantages to wireless communication systems, the impact of noise variations known as noise uncertainty and the inability of selecting an optimal signal level threshold for deciding upon the presence of the primary user signal can compromise the sensing precision of the energy detection method. Since the energy detection may be enhanced by dynamic detection threshold adjustments, this manuscript analyses the influence of detection threshold adjustments and noise uncertainty on the performance of the energy detection spectrum sensing method in single-cell cognitive radio systems. For the evaluation of an energy detection method based on the square-law combining technique, the mathematical expressions of the main performance parameters used for the assessment of spectrum sensing efficiency have been derived. The developed expressions were further assessed by executing the algorithm that enabled the simulation of the energy detection method based on the square-law combining technique in Multiple-Input Multiple-Output—Orthogonal Frequency Division Multiplexing cognitive radio systems. The obtained simulation results provide insights into how different levels of detection threshold adjustments and noise uncertainty affect the probability of detection of primary user signals. It is shown that higher signal-to-noise-ratios, the transmitting powers of primary user, the number of primary user transmitting and the secondary user receiving antennas, the number of sampling points and the false alarm probabilities improve detection probability. The presented analyses establish the basis for understanding the energy detection operation through the possibility of exploiting the different combinations of operating parameters which can contribute to the improvement of spectrum sensing efficiency of the energy detection method.


Author(s):  
Rachael C Tighe ◽  
Jonathon Hill ◽  
Tom Vosper ◽  
Cody Taylor ◽  
Tairongo Tuhiwai

Abstract Thermographic inspection provides opportunity to tailor non-destructive evaluation to specific applications. The paper discusses the opportunities this presents through consideration of adhesive bonds between composites, such as those joining structural members and outer skins, where access is restricted to a single side. To date, literature focusses on the development of either an experimental procedure or data processing approach. This research aims to demonstrate the importance of tailoring both of these aspects to an application to obtain improved defect detection and robust quantification. Firstly, the heating stimulus is optimised to maximise the thermal contrast created between defect and non-defect regions using a development panel. Traditional flash heating is compared to longer square pulse heating, using a developed shutter system, compromising between experimental duration and heat input. A pulse duration of 4 seconds using two 130 W halogen bulbs was found double the detection depth from 1 mm to 2 mm, revealing all defects in the development panel. Temporal processing was maintained for all data using thermal signal reconstruction. Spatial defect detection routines were then implemented to provide robust defect/feature detection. Spatial defect detection encompassed a combination of image enhancement and edge detection algorithms. A two-stage kernel filter/binary enhancement method followed by the use of Canny edge detection was found most robust, providing a sizing error of 1.8 % on the development panel data. This process was then implemented on adhesive bonds with simulated bond line defects. The simulated defects are based on target detection threshold of 10 mm diameter void found at 1- 2 mm depth. All simulated void defects were detected in the representative bonded joint down to the minimum diameter tested of 5 mm. By considering the tailoring of multiple aspects of the inspection routine independently, an overall optimised approach for the application of interest has been defined.


Author(s):  
Boudewijn van den Berg ◽  
Hemme J. Hijma ◽  
Ingrid Koopmans ◽  
Robert J. Doll ◽  
Rob G. J. A. Zuiker ◽  
...  

AbstractSleep deprivation has been shown to increase pain intensity and decrease pain thresholds in healthy subjects. In chronic pain patients, sleep impairment often worsens the perceived pain intensity. This increased pain perception is the result of altered nociceptive processing. We recently developed a method to quantify and monitor altered nociceptive processing by simultaneous tracking of psychophysical detection thresholds and recording of evoked cortical potentials during intra-epidermal electric stimulation. In this study, we assessed the sensitivity of nociceptive detection thresholds and evoked potentials to altered nociceptive processing after sleep deprivation in an exploratory study with 24 healthy male and 24 healthy female subjects. In each subject, we tracked nociceptive detection thresholds and recorded central evoked potentials in response to 180 single- and 180 double-pulse intra-epidermal electric stimuli. Results showed that the detection thresholds for single- and double-pulse stimuli and the average central evoked potential for single-pulse stimuli were significantly decreased after sleep deprivation. When analyzed separated by sex, these effects were only significant in the male population. Multivariate analysis showed that the decrease of central evoked potential was associated with a decrease of task-related evoked activity. Measurement repetition led to a decrease of the detection threshold to double-pulse stimuli in the mixed and the female population, but did not significantly affect any other outcome measures. These results suggest that simultaneous tracking of psychophysical detection thresholds and evoked potentials is a useful method to observe altered nociceptive processing after sleep deprivation, but is also sensitive to sex differences and measurement repetition.


2022 ◽  
Vol 12 ◽  
Author(s):  
Yushan Bu ◽  
Wenjun Qiao ◽  
Zhengyuan Zhai ◽  
Tongjie Liu ◽  
Pimin Gong ◽  
...  

Raw milk is susceptible to microbial contamination during transportation and storage. Pseudomonas fluorescens producing heat-resistant enzymes have become the most common and harmful psychrophilic microorganisms in the cold chain logistics of raw milk. To rapidly detect P. fluorescens in raw milk, the protease gene aprX was selected as a detection target to construct a set of primers with strong specificity, and a loop-mediated isothermal amplification (LAMP) assay was established. The detection thresholds of the LAMP assay for pure cultured P. fluorescens and pasteurized milk were 2.57 × 102 and 3 × 102 CFU/mL, respectively. It had the advantages over conventional method of low detection threshold, strong specificity, rapid detection, and simple operation. This LAMP assay can be used for online monitoring and on-site detection of P. fluorescens in raw milk to guarantee the quality and safety of dairy products.


Author(s):  
Jade Daigle ◽  
Kathleen Racher ◽  
Justin Hazenberg ◽  
Allan Yeoman ◽  
Heather Hannah ◽  
...  

Throughout the COVID-19 pandemic, wastewater surveillance has been used to monitor trends in SARS-CoV-2 prevalence in the community. A major challenge in establishing wastewater surveillance programs, especially in remote areas, is the need for a well-equipped laboratory for sample analysis. Currently, no options exist for rapid, sensitive, mobile, and easy-to-use wastewater tests for SARS-CoV-2. The performance of the GeneXpert System, which offers cartridge-based, rapid molecular clinical testing for SARS-CoV-2 in a portable platform, was evaluated using wastewater as the input. The GeneXpert demonstrated a SARS-CoV-2 limit of detection in wastewater below 32 copies/mL with a sample processing time of less than an hour. Using wastewater samples collected from multiple sites across Canada during February and March 2021, a high overall agreement (97.8%) was observed between the GeneXpert assay and laboratory-developed tests regarding the presence or absence of SARS-CoV-2. Additionally, with the use of centrifugal filters the detection threshold of the GeneXpert system was improved to <10 copies/mL in wastewater. Finally, to support on-site wastewater surveillance, GeneXpert testing was implemented in Yellowknife, a remote community in Northern Canada where its use successfully alerted public health authorities to undetected transmission of COVID-19. The identification of SARS-CoV-2 in wastewater triggered clinical testing of recent travelers and identification of new COVID-19 cases/clusters. Taken together, these results suggest the GeneXpert is a viable option for surveillance of SARS-CoV-2 in wastewater in locations that do not have access to established testing laboratories. Importance: Wastewater-based surveillance is a powerful tool that provides an unbiased measure of COVID-19 prevalence in a community. This work describes a sensitive wastewater rapid test for SARS-CoV-2 based on a widely distributed technology, the GeneXpert. The advantages of an easy-to-use wastewater test for SARS-CoV-2 are clear – it supports surveillance in remote communities, improves access to testing, and provides faster results allowing for an immediate public health response. The application of wastewater rapid testing in a remote community facilitated the detection of a COVID-19 cluster and triggered public health action, clearly demonstrating the utility of this technology. Wastewater surveillance will become increasingly important in the post-vaccination pandemic landscape as individuals with asymptomatic/mild infections continue transmitting SARS-CoV-2 but are unlikely to be tested.


2022 ◽  
Vol 82 (1) ◽  
Author(s):  
S. Aiello ◽  
A. Albert ◽  
S. Alves Garre ◽  
Z. Aly ◽  
A. Ambrosone ◽  
...  

AbstractThe next generation of water Cherenkov neutrino telescopes in the Mediterranean Sea are under construction offshore France (KM3NeT/ORCA) and Sicily (KM3NeT/ARCA). The KM3NeT/ORCA detector features an energy detection threshold which allows to collect atmospheric neutrinos to study flavour oscillation. This paper reports the KM3NeT/ORCA sensitivity to this phenomenon. The event reconstruction, selection and classification are described. The sensitivity to determine the neutrino mass ordering was evaluated and found to be 4.4$$\sigma $$ σ if the true ordering is normal and 2.3$$\sigma $$ σ if inverted, after 3 years of data taking. The precision to measure $$\varDelta m^2_{32}$$ Δ m 32 2 and $$\theta _{23}$$ θ 23 were also estimated and found to be $$85 . 10^{-6}~{\mathrm{eV}^{2}}$$ 85 . 10 - 6 eV 2 and $$(^{+1.9}_{-3.1})^{\circ }$$ ( - 3.1 + 1.9 ) ∘ for normal neutrino mass ordering and, $$75 . 10^{-6}~{\mathrm{eV}^{2}}$$ 75 . 10 - 6 eV 2 and $$(^{+2.0}_{-7.0})^{\circ }$$ ( - 7.0 + 2.0 ) ∘ for inverted ordering. Finally, a unitarity test of the leptonic mixing matrix by measuring the rate of tau neutrinos is described. Three years of data taking were found to be sufficient to exclude "Equation missing" event rate variations larger than 20% at $$3\sigma $$ 3 σ level.


2021 ◽  
Vol 2 ◽  
Author(s):  
Rima El-Sayed ◽  
Camille Fauchon ◽  
Junseok A. Kim ◽  
Shahrzad Firouzian ◽  
Natalie R. Osborne ◽  
...  

Conditioned pain modulation (CPM) is a physiological measure thought to reflect an individual's endogenous pain modulation system. CPM varies across individuals and provides insight into chronic pain pathophysiology. There is growing evidence that CPM may help predict individual pain treatment outcome. However, paradigm variabilities and practical issues have impeded widespread clinical adoption of CPM assessment. This study aimed to compare two CPM paradigms in people with chronic pain and healthy individuals. A total of 30 individuals (12 chronic pain, 18 healthy) underwent two CPM paradigms. The heat CPM paradigm acquired pain intensity ratings evoked by a test stimulus (TS) applied before and during the conditioning stimulus (CS). The pressure CPM paradigm acquired continuous pain intensity ratings of a gradually increasing TS, before and during CS. Pain intensity was rated from 0 (no pain) to 100 (worst pain imaginable); Pain50 is the stimulus level for a response rated 50. Heat and pressure CPM were calculated as a change in TS pain intensity ratings at Pain50, where negative CPM scores indicate pain inhibition. We also determined CPM in the pressure paradigm as change in pressure pain detection threshold (PDT). We found that in healthy individuals the CPM effect was significantly more inhibitory using the pressure paradigm than the heat paradigm. The pressure CPM effect was also significantly more inhibitory when based on changes at Pain50 than at PDT. However, in individuals with chronic pain there was no significant difference in pressure CPM compared to heat or PDT CPM. There was no significant correlation between clinical pain measures (painDETECT and Brief Pain Inventory) and paradigm type (heat vs. pressure), although heat-based CPM and painDETECT scores showed a trend. Importantly, the pressure paradigm could be administered in less time than the heat paradigm. Thus, our study indicates that in healthy individuals, interpretation of CPM findings should consider potential modality-dependent effects. However, in individuals with chronic pain, either heat or pressure paradigms can similarly be used to assess CPM. Given the practical advantages of the pressure paradigm (e.g., short test time, ease of use), we propose this approach to be well-suited for clinical adoption.


2021 ◽  
Vol 2 ◽  
Author(s):  
Tania Augière ◽  
Audrey Desjardins ◽  
Emmanuelle Paquette Raynard ◽  
Clémentine Brun ◽  
Anne Marie Pinard ◽  
...  

Fibromyalgia is a chronic pain syndrome characterized by sensorimotor deficits and distortions of body representation, that could both be caused by alterations in sensory processing. Several studies suggest a hypersensitivity to various sensory stimulations in fibromyalgia but results on detection of both noxious and non-noxious tactile stimulation, which are particularly relevant for body representation and motor control, remain conflicting. Therefore, the aim of this study is to systematically review and quantify the detection thresholds to noxious and non-noxious tactile stimuli in individuals with fibromyalgia compared to pain-free controls. A systematic review and a meta-analysis were performed in the MEDLINE, EMBASE, CINAHL, Cochrane, PsycInfo and Web of Science databases using keywords related to fibromyalgia, tactile pain detection threshold, tactile detection threshold and quantitative sensory testing. Nineteen studies were included in the review, with 12 in the meta-analysis. Despite the heterogeneity of the results, the data from both the review and from the meta-analysis suggest a trend toward hyperalgesia and no difference of sensitivity to non-noxious tactile stimuli in participants with fibromyalgia compared to healthy controls. This contradicts the hypothesis of a general increase in responsiveness of the central nervous system to noxious and non-noxious stimulations in fibromyalgia. This study shows no alteration of the sensitivity to non-noxious tactile stimulation in fibromyalgia, suggesting that an altered unimodal processing is not sufficient to explain symptoms such as sensorimotor impairments and body representation distortions. Future research should investigate whether alterations in multisensory integration could contribute to these symptoms.


Sign in / Sign up

Export Citation Format

Share Document