scholarly journals Development of the design and justification of the parameters of the guide rapier of the weaving machine

2021 ◽  
Vol 2094 (4) ◽  
pp. 042029
Author(s):  
A Djuraev ◽  
Sh Madrakhimov ◽  
M Erkinov

Abstract The article describes the design feature and the principle of operation of the recommended pattern of the weaving rapier guide. On the basis of theoretical studies, graphical dependencies of the parameters of the guide roller were adjusted, the system parameters were recommended by analyzes.

2018 ◽  
Vol 10 ◽  
pp. 01001
Author(s):  
Aliaksandr Basareuski

One of the major parameters of a hydraulic machine is its energy intensity, i.e. its power/output ratio. This article presents the results of theoretical studies of the effects of additional head loss of transporting fluid through helically coiled flexible pipe on specific energy consumption of fertigation machinery and pipeline transport. Computational methods have been used to determine that pressure loss will be 15-20% higher on the average than the loss at a straight section, depending on the average radius of coil helix/design pipe diameter ratio. Correlations have been obtained that allow for justification of major mobile fertilizer system parameters based on the need to minimize pressure loss.


Author(s):  
Orif Murodov ◽  
Shavkat Madrahimov ◽  
Ziyodullo Shodiyev

The article discusses the results of theoretical studies of vibrations of a plastic grate on elastic supports of a coarse litter cleaner under accidental exposure to raw cotton. Graphical dependences of changes in displacements and vibration rate of the grate on changes in the coefficients of stiffness, dissipation and on the disturbing load from raw cotton at various values of the grate mass are constructed. Based on the analysis of the obtained graphical dependencies, the values of the system parameters are recommended. KEYWORDS: plastic grates, elastic supports, raw cotton, plastic pipes, mass, polyethylene, stiffness coefficient.


2019 ◽  
Vol 8 (2) ◽  
pp. 5806-5811 ◽  

The article provides an analysis of existing separators for raw cotton. Their disadvantages are described. The design scheme and the principle of operation of the separator with side grids of the air duct with curved conical holes are presented. The results of theoretical studies to determine the strength of Stripping and justification of the system parameters. The results of comparative production tests of the recommended separator design for fibrous materials are presented.


1979 ◽  
Vol 46 ◽  
pp. 65-74 ◽  
Author(s):  
A.C. Fabian ◽  
J.E. Pringle ◽  
J.A.J. Whelan ◽  
J.A. Bailey

Abstract.Recent photometric and spectroscopic observations of the dwarf nova system Z Cha are discussed. Methods for constraining the system parameters are applied and the disc emissivity is deduced as a function of radius. Indications are found that the disc shrinks in size with increasing time after outburst.


1977 ◽  
Vol 37 (02) ◽  
pp. 243-252
Author(s):  
Yi-Hsiang Chen ◽  
E. B Reeve

SummaryTo shed some light on the homeostatic regulation of plasma fibrinogen, metabolic studies were made in healthy females, and in normal, thyroidectomized, and thyroxine-treated rabbits. In females, compared with normal males, plasma fibrinogen concentration, plasma and interstitial fibrinogen decreased consequent to an increased fractional catabolic rate and a normal fibrinogen synthesis rate. The interstitial/plasma fibrinogen ratio remained unchanged. In normal rabbits, with increasing body weight fractional catabolic rate and catabolic rate decreased, while fibrinogen concentration and plasma fibrinogen remained constant owing to a simultaneous decrease in fibrinogen synthesis. In addition, fractional transcapillary transfer rate and transcapillary flux also decreased resulting in a shrinkage of interstitial fibrinogen. Thyroidectomy and thyroxine-injection markedly altered fibrinogen metabolism: thyroid hormone accelerated fibrinogen catabolism but also stimulated synthesis. The net result was an increase in plasma fibrinogen and fibrinogen concentration. The interstitial/plasma fibrinogen ratio decreased in thyroxine-treated, and increased in thyroidectomized animals. This study defines the variations of the fibrinogen system parameters in these physiologic and pathologic conditions, and illustrates some patterns of alterations in fibrinogen metabolism.


Sign in / Sign up

Export Citation Format

Share Document