Schemes for producing multi-energy fast neutrons using a low-energy ion accelerator

2021 ◽  
Vol 16 (09) ◽  
pp. T09003
Author(s):  
G. Mishra ◽  
R.G. Thomas ◽  
Ajay Kumar ◽  
Sukanya De ◽  
A. Mitra ◽  
...  
1983 ◽  
Vol 206 (1-2) ◽  
pp. 107-117 ◽  
Author(s):  
Masaaki Kobayashi ◽  
Kenjiro Kondo ◽  
Hiromi Hirabayashi ◽  
Shin-ichi Kurokawa ◽  
Mitsuhiko Taino ◽  
...  

Author(s):  
A. Lorusso ◽  
L. Velardi ◽  
V. Nassisi ◽  
F. Paladini ◽  
A.M. Visco ◽  
...  

2013 ◽  
Vol 37 (12) ◽  
pp. 127001 ◽  
Author(s):  
Zhi-Jun Wang ◽  
Yuan He ◽  
A. A. Kolomiets ◽  
Shu-Hui Liu ◽  
Xiao-Nan Du ◽  
...  

2018 ◽  
Vol 170 ◽  
pp. 07002 ◽  
Author(s):  
Cathleen Barker ◽  
Ting Zhu ◽  
Lucas Rolison ◽  
Scott Kiff ◽  
Kelly Jordan ◽  
...  

Using natural helium (helium-4), the Arktis 180-bar pressurized gas scintillator is capable of detecting and distinguishing fast neutrons and gammas. The detector has a unique design of three optically separated segments in which 12 silicon-photomultiplier (SiPM) pairs are positioned equilaterally across the detector to allow for them to be fully immersed in the helium-4 gas volume; consequently, no additional optical interfaces are necessary. The SiPM signals were amplified, shaped, and readout by an analog board; a 250 MHz, 14-bit digitizer was used to examine the output pulses from each SiPMpair channel. The SiPM over-voltage had to be adjusted in order to reduce pulse clipping and negative overshoot, which was observed for events with high scintillation production. Pulse shaped discrimination (PSD) was conducted by evaluating three different parameters: time over threshold (TOT), pulse amplitude, and pulse integral. In order to differentiate high and low energy events, a 30ns gate window was implemented to group pulses from two SiPM channels or more for the calculation of TOT. It was demonstrated that pulses from a single SiPM channel within the 30ns window corresponded to low-energy gamma events while groups of pulses from two-channels or more were most likely neutron events. Due to gamma pulses having lower pulse amplitude, the percentage of measured gamma also depends on the threshold value in TOT calculations. Similarly, the threshold values were varied for the optimal PSD methods of using pulse amplitude and pulse area parameters. Helium-4 detectors equipped with SiPMs are excellent for in-the-field radiation measurement of nuclear spent fuel casks. With optimized PSD methods, the goal of developing a fuel cask content monitoring and inspection system based on these helium-4 detectors will be achieved.


2011 ◽  
Vol T144 ◽  
pp. 014038 ◽  
Author(s):  
A N Agnihotri ◽  
A H Kelkar ◽  
S Kasthurirangan ◽  
K V Thulasiram ◽  
C A Desai ◽  
...  

2016 ◽  
Vol 11 (08) ◽  
pp. P08011-P08011 ◽  
Author(s):  
Q. Riffard ◽  
D. Santos ◽  
O. Guillaudin ◽  
G. Bosson ◽  
O. Bourrion ◽  
...  

1965 ◽  
Vol 12 (3) ◽  
pp. 282-287 ◽  
Author(s):  
R. Laubert ◽  
N. Wotherspoon

Sign in / Sign up

Export Citation Format

Share Document