scholarly journals CFD analysis on the influence of angle of attack on vertical axis wind turbine aerodynamics

2021 ◽  
Vol 850 (1) ◽  
pp. 012027
Author(s):  
Prateek Srivastava ◽  
Sachin Kansal ◽  
Ashish Talwalkar ◽  
R Harish

Abstract The Angle of Attack (AOA) in a Vertical Axis Wind Turbine (VAWT) plays an important role in determining the forces and the power generated by the wind turbine. It is difficult to find the suitable AOA due to the complex and constantly changing wind flow patterns. In this paper, we have performed CFD simulations using Ansys Fluent software, based on the constantly changing AOA. The CFD simulations were conducted by selecting a suitable range of AOA and the velocity of the wind. The selected range of AOA varied from 5 degrees to 25 degrees with increments of 5 degrees and the range of the air velocities varied from 7m/s to 21m/s with increments of 7m/s. The tests were also performed using the X-Foil software. The results obtained from the CFD simulations, done by using the Ansys Fluent Software and from the X-Foil software, were then compared to give a more accurate and optimized AOA and velocity value. This optimization of the AOA could enhance the overall performance of the Vertical Axis Wind turbine.

2018 ◽  
Vol 8 (4) ◽  
pp. 3282-3286
Author(s):  
I. Malael ◽  
V. Dragan

This paper investigates the concept of a concentric counter-rotating vertical axis wind turbine (VAWT), consisting of a two stage vertical H-type turbine with three blades on each stage. The model has an inner and an outer stage, rotating in opposition to each other. Both numerical and experimental tests have been performed in order to validate this new concept. Numerical analysis is based on the use of 2.5-dimensional, unsteady simulations using a DOF type of analysis which allows for the two stages to self-adjust their rotation speed. Sliding mesh conformal interfaces are defined between these subdomains to minimize numerical artifacts such as artificial relations or entropy changes. Fully turbulent URANS were carried out in Ansys Fluent software. One key outcome was the momentum coefficient for each stage at different tip wind speed values. Another, more qualitative, outcome is the analysis of vortex shedding, impingement and overall interaction between the stages at different positions and scenarios. Ultimately, the numerical results have been validated using a scaled experimental device which was analyzed in the wind tunnel at different free stream speeds.


2019 ◽  
Vol 182 ◽  
pp. 154-165 ◽  
Author(s):  
Mohamed M. Elsakka ◽  
Derek B. Ingham ◽  
Lin Ma ◽  
Mohamed Pourkashanian

Author(s):  
Muhammed Musab Gavgali ◽  
Zbigniew Czyż ◽  
Jacek Czarnigowski

The paper presents the results of calculations of flow around the vertical axis wind turbine. Three-dimensional calculations were performed using ANSYS Fluent. They were made at steady-state conditions for a wind speed of 3 m/s for 4 angular settings of the three-bladed rotor. The purpose of the calculations was to determine the values of the aerodynamic forces acting on the individual blades and to present the pressure contours on the surface of turbine rotor blades. The calculations were made for 4 rotor angular settings


2015 ◽  
Vol 18 (4) ◽  
pp. 145-152
Author(s):  
Anh Ngoc Vu ◽  
Tung Nguyen Minh Huynh

This paper presents an automated process for analyzing the performance of vertical axis wind turbine (VAWT). The details of this process will be demonstrated, which include the airfoil geometry representation using CST method, a hybrid meshing process combining structured grids and unstructured grids, CFD calculation process and processing data results to calculate the power coefficient of VAWT. These processes are designed as separate modules. CFD methods used in this research is RANS 2D using Realizable k  turbulence model. Meshing process will be done on the GAMBIT software, the CFD calculations are done on commercial ANSYS FLUENT software and these processes are controlled by mathematical software MATLAB. The formulas used to calculate the power coefficient will be also introduced in this paper.


2021 ◽  
Vol 11 (3) ◽  
pp. 1033
Author(s):  
Jia Guo ◽  
Timing Qu ◽  
Liping Lei

Pitch regulation plays a significant role in improving power performance and achieving output control in wind turbines. The present study focuses on a novel, pitch-regulated vertical axis wind turbine (VAWT) with inclined pitch axes. The effect of two pitch parameters (the fold angle and the incline angle) on the instantaneous aerodynamic forces and overall performance of a straight-bladed VAWT under a tip-speed ratio of 4 is investigated using an actuator line model, achieved in ANSYS Fluent software and validated by previous experimental results. The results demonstrate that the fold angle has an apparent influence on the angles of attack and forces of the blades, as well as the power output of the wind turbine. It is helpful to further study the dynamic pitch regulation and adaptable passive pitch regulation of VAWTs. Incline angles away from 90° lead to the asymmetric distribution of aerodynamic forces along the blade span, which results in an expected reduction of loads on the main shaft and the tower of VAWTs.


Author(s):  
WAHYU AULIA NURWICAKSANA ◽  
BUDHY SETIAWAN ◽  
IKA NOER SYAMSIANA ◽  
SEPTYANA RISKITASARI

ABSTRAKVAWT (Vertical Axis Wind Turbine) tipe Darrieus NACA0015 merupakan salah satu model dari turbin angin yang bekerja dengan menggunakan angin sebagai sumber penggerak. Namun dari hasil pengamatan, kecepatan angin yang ada tidak konstan setiap saat. Sehingga dari permasalahan ini perlu suatu kontrol yaitu dengan mengendalikan sudut kerja blade VAWT yang dikenal dengan kontrol angle of attack (AoA). Prinsip kerja kontrol AoA yaitu sudut blade diatur agar VAWT bekerja secara optimum dan dapat meningkatkan efisiensi. Metode kontrol AoA menggunakan PID (Proportional–Integral–Derivative) dengan memberikan nilai trial and error pada Kp, Ki, Kd. VAWT ini menggunakan konstanta TSR (Tip Speed Ratio) yaitu 4. Hasil dari penelitian ini yaitu daya yang dihasilkan VAWT dengan kontrol AoA mendapatkan rata-rata efisiensi sebesar 5.16%, sedangkan VAWT tanpa kontrol mendapatkan efisiensi sebesar 3.49%. Sehingga dapat disimpulkan bahwa dengan kontrol AoA, rata-rata efisiensi dayanya naik sebesar 1.67% dari yang tanpa kontrol.Kata Kunci: Kontrol Angle of Attack (AoA), VAWT, TSR, Efisiensi ABSTRACTVAWT (Vertical Axis Wind Turbine) type Darrieus NACA0015 is one model of a wind turbine that works by using wind as a source of propulsion. Conditions from observations, wind speeds that are not constant every time. So from this problem needs control VAWT by controlling the working angle of the VAWT blade is the angle of attack control (AoA). The principle AoA control is that the blade angle adjusted so that the VAWT works optimally and can improve the efficiency. AoA control method uses PID (Proportional-Integral-Derivative) by providing trial and error values for Kp, Ki, Kd. VAWT uses TSR (Tip Speed Ratio) constant which is 4. The results of this research, VAWT with AoA control get an average efficiency of 5.16%, while without control gets an average efficiency of 3.49%. So it can be concluded that with AoA control, the average power efficiency increases by 1.67% from those without control.Keywords: Angle of Attack (AoA) Control, VAWT, TSR, Efficiency


Sign in / Sign up

Export Citation Format

Share Document