Delayed Presentation of Ilio-Iliac Arteriovenous Fistula Following Laparoscopic Cholecystectomy Treated with Percutaneous Graft-Covered Stent Placement

2005 ◽  
Vol 15 (4) ◽  
pp. 411-414 ◽  
Author(s):  
Michael Karigiannis ◽  
George Pavlidis ◽  
George Papageorgiou ◽  
Christos Feretis ◽  
Konstantinos M. Stamou ◽  
...  
2020 ◽  
Vol 2020 (3) ◽  
Author(s):  
Alexandra Stathis ◽  
John Gan

Abstract A 64-year-old lady presented with a 6-month history of worsening unilateral leg swelling, with an audible bruit of the popliteal artery. Arterial duplex ultrasound confirmed the presence of an arteriovenous fistula (AVF) between the posterior tibial artery and vein. Upon thorough history, it was discovered that the patient had sustained a stab wound to this region some 25 years prior. The fistula was successfully managed endovascularly by means of a covered stent. This case highlights an unusual delayed presentation of an AVF and demonstrates the effectiveness of endovascular treatment of this condition.


Author(s):  
Diana M. Torpoco Rivera ◽  
Rachel Taylor ◽  
Andrew Fox ◽  
Thomas J. Forbes ◽  
Daisuke Kobayashi

Arteriovenous fistula (AVF) creation is used to palliate complex cyanotic heart diseases. We report an adult patient with AVF creation who subsequently developed severe left subclavian vein stenosis, causing significant left arm swelling. Covered stent placement successfully treated the venous stenosis, resulting in the normalization of his left arm swelling.


2008 ◽  
Vol 108 (3) ◽  
pp. 588-590 ◽  
Author(s):  
Xian-Li Lv ◽  
You-Xiang Li ◽  
Ai-Hua Liu ◽  
Ming Lv ◽  
Peng Jiang ◽  
...  

✓The authors present the case of a patient with a direct carotid artery–cavernous sinus fistula caused by head trauma in whom a self-expanding covered stent was successfully used to obliterate the fistula. However, at the 9-month follow-up an angiogram revealed a complex caroticocavernous fistula that was completely obliterated with Onyx 18 transarterially.


Author(s):  
Yuan-Mao Lin ◽  
Ethan Yiyang Lin ◽  
Hsiuo-Shan Tseng ◽  
Rheun-Chuan Lee ◽  
Hsuen-En Huang ◽  
...  

Cancers ◽  
2021 ◽  
Vol 13 (15) ◽  
pp. 3720
Author(s):  
Young-Il Kim ◽  
Chan Gyoo Kim ◽  
Jong Yeul Lee ◽  
Il Ju Choi ◽  
Bang Wool Eom ◽  
...  

A thread-fix stent entails long hospitalization and patient discomfort. We aimed to evaluate the efficacy of a novel stent with silicone-covered outer double layers without external fixation (Beta stent) for anastomotic leakage after total or proximal gastrectomy. The outcomes were compared between gastric cancer patients who underwent stent placement using a thread-fix stent between 2014 and 2015 (Thread-Fix Group) and those who received a Beta stent in the succeeding period until October 2018 (Beta Stent Group). The Beta Stent Group (n = 14) had a significantly higher leakage healing rate by the first stent placement (92.9% vs. 53.8%; p = 0.021) and had a shorter hospitalization period (median: 16 days vs. 28 days; p = 0.037) than the Thread-Fix Group (n = 13). Further, 50% of the Beta stent patients received outpatient management until stent removal. Stent maintenance duration was significantly longer in the Beta Stent Group (median, 28 days vs. 18 days; p = 0.006). There was no significant between-group difference in stent-related complications except for stent migration (7.1% (Beta Stent Group) vs. 0% (Thread-Fix Group), p = 0.326). In conclusion, the Niti-S Beta stent is an effective treatment for anastomotic leakage from total or proximal gastrectomy for gastric cancer. Stent maintenance is possible without hospitalization.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Zong-Ming Li ◽  
De-Chao Jiao ◽  
Xin-Wei Han ◽  
Hui-Bin Lu ◽  
Ke-Wei Ren ◽  
...  

Abstract Background Long-term placement of airway stents has a high probability of restenosis of the airway due to granulation tissue hyperplasia, and it is difficult to remove the stent. Our aim is to evaluate the success rate and complications of removal of tracheal tube metallic stents under fluoroscopic guidance, and to compare the difference between uncovered stent and covered stent. Methods We retrospectively reviewed 45 cases (31 males and 14 females; age, 12–71 years) of tracheal metallic stent removal performed at our center between January 2014 and December 2019. Covered stents were applied in 36 cases, and uncovered stents were applied in 9 cases. In the covered stent group, 15 patients presented with granulation tissue at both ends; 3 cases, with stent fracture; and 2, with stent intolerance due to severe airway foreign body sensation. In the uncovered stents group, all patients presented with granulation tissue formation; 2 patients, with stent fracture; and 1 patient, with stent intolerance. Results A total of 41 (91.1%) stents were successfully removed (34 [94.4%] in the covered stent group and 7 [77.8%] in the uncovered stent group). The average duration of stent placement was 3.2 ± 0.7 and 2.5 ± 1.2 months in the covered stent group and uncovered stent group, respectively. With regard to the complications, hemoptysis occurred in 4 cases (average blood volume lost, 100 ml), tracheal mucosa tear occurred in 5 cases, tracheal collapse requiring emergency airway stent placement occurred in 1 case, and tracheal rupture requiring emergency surgical suture occurred in 1 case. No procedure-related deaths occurred in either group. Conclusions It is safe to remove the metal stent of the tracheal tube under the guidance of fluoroscopy, with low complications, and can avoid the long-term placement of the airway stent.


2016 ◽  
Vol 2016 ◽  
pp. 1-3 ◽  
Author(s):  
Ender Ornek ◽  
Harun Kundi ◽  
Emrullah Kiziltunc ◽  
Mustafa Cetin

An 83-year-old man, who underwent coronary artery bypass operation of left internal mammary artery (LIMA) to left anterior descending (LAD) artery, with sequential saphenous vein to the first and second obtuse marginal (OM) branches of circumflex artery 5 years ago and coronary artery stent implantation to right coronary artery 2 months ago, was admitted to the hospital with syncope and chest pain. Aortosaphenous graft selective angiography revealed that first sequential side to side ligation was inadvertently anastomosed to left posterolateral coronary vein with resultant flow into the coronary sinus and distal end to side sequential anastomosis to OM 2 coronary artery which was filling very weakly. In order to close this iatrogenic coronary arteriovenous fistula and to supply saphenous vein flow to OM artery, we decided to implant a graft covered stent into the saphenous vein at the same session.


2018 ◽  
Vol 02 (01) ◽  
pp. 025-032
Author(s):  
Wei-Zhong Zhou ◽  
Zheng-Qiang Yang

AbstractGastric outlet obstruction (GOO) is a clinical consequence of any disease that produces intrinsic or extrinsic obstruction of the pyloric channel or duodenum. The most common symptoms of GOO include nausea, vomiting, abdominal pain, and weight loss. Traditionally, surgery is regarded as the standard treatment modality. However, with the development of mini-invasive technologies, fluoroscopic or endoscopic stenting and balloon dilatation have become the mainstream of the therapies. The initial recommended treatment for malignant GOO is self-expanding metal stent placement. The stent can be classified into covered and uncovered stent according to whether it is coated with a membrane. Covered stent seems to have longer stent patency, while uncovered stent has the advantage of a lower migration rate. Regarding the etiology of benign GOO, peptic ulcer disease and corrosive injury are the two main reasons. Balloon dilatation is a simple and convenient way to treat the benign GOO. Stent placement has recently been reported for the treatment of benign GOO; however, it needs further more studies to verify its effect. This article presents a concise review of current fluoroscopic or endoscopic stenting practice for malignant GOO and balloon dilatation or stenting for benign GOO.


Sign in / Sign up

Export Citation Format

Share Document