Definitive liquid-chromatographic demonstration that N-ethylglycine is the metabolite of lidocaine that interferes in the Kodak sarcosine oxidase-coupled method for creatinine.

1988 ◽  
Vol 34 (12) ◽  
pp. 2569-2572 ◽  
Author(s):  
R T Roberts ◽  
N M Alexander ◽  
M J Kelner

Abstract Patients receiving lidocaine may show false increases of serum creatinine as assayed by the single-slide method on the Kodak Ektachem 700. Bissell et al. (Clin Chem 1987;33:951) suggested that this interference was due to oxidation of N-ethylglycine (NEG), a previously uncharacterized metabolite of lidocaine, by the sarcosine oxidase preparation used in the Ektachem creatinine slide. To investigate this possibility, we synthesized NEG, added it to drug-free human serum, and analyzed the NEG-supplemented sera for creatinine with the Ektachem 700. We found the following linear relationships between creatinine bias (y, mg/L) and NEG concentration (x, mg/L) for first (I), third (III), and fourth (IV) generation slides: I: y = 1.70x - 0.8 mg/L (n = 13, r = 1.0) III: y = 0.39x - 0.3 mg/L (n = 3, r = 1.0) IV: y = 0.79x - 1.8 mg/L (n = 13, r = 1.0) Using HPLC, we directly demonstrated the presence of NEG in sera of patients receiving lidocaine and quantified NEG concentrations in sera from four of these patients. The increasing artifactual bias in creatinine with increasing NEG concentration unequivocally confirmed that NEG is responsible for the lidocaine-associated interference in the Kodak Ektachem single-slide creatinine method.

1989 ◽  
Vol 35 (12) ◽  
pp. 2285-2289 ◽  
Author(s):  
B E Cham ◽  
H P Roeser ◽  
T W Kamst

Abstract We describe a high-performance liquid chromatographic procedure for the simultaneous measurement of vitamins K1 and E in human serum. Delipidated human serum (free of vitamins K1 and E) was used to make standard solutions of these vitamins, and cetyl naphthoate and alpha-tocopheryl acetate were the internal standards for vitamin K1 and vitamin E, respectively. A simple, novel separation method utilizing liquid-liquid partition chromatography was used as a preparative "clean-up" procedure. Cetyl naphthoate and vitamin K1 (after post-column reduction) were detected by fluorescence, alpha-tocopheryl acetate and vitamin E by ultraviolet absorption. Sensitivity (detection limit) of the assay was 30 pg for vitamin K1 and 5 ng for vitamin E per injection. The method is specific, precise, and more rapid than previously described procedures. Within- and between-assay CVs were 8.1% and 12.9%, respectively, for vitamin K1; 3.5% and 6.0%, respectively, for vitamin E. Analytical recoveries of vitamins K1 and E were 80% and 93%, respectively, from serum and from delipidated serum (standards). The average neonatal serum concentration of vitamin K1 was 83 ng/L, 2.5 mg/L for vitamin E; for normolipidemic adults, the values were 343 ng/L and 7.9 mg/L, respectively, and for hyperlipidemic adults, 541 ng/L and 11.1 mg/L, respectively.


Sign in / Sign up

Export Citation Format

Share Document