Isotopic and nonisotopic assays for measuring somatotropin compared: re-evaluation of cutoff value in provocative tests

1991 ◽  
Vol 37 (2) ◽  
pp. 273-276 ◽  
Author(s):  
Gluseppe Banfi ◽  
Marcello Marinelli ◽  
Ermlnla Casari ◽  
Michelangelo Murone ◽  
Plerangel Bonini

Abstract Measurement of human growth hormone (hGH; somatotropin) concentrations in serum after provocative tests is crucial for diagnosing deficiencies in production of this hormone. Serum hGH can be measured by various immunoassays, isotopic and nonisotopic, with monoclonal or polyclonal antibodies: a cutoff value of 10 micrograms/L after provocative testing is usually used to distinguish normal from hGH-deficient children. Previous studies demonstrated discrepancies in hGH measurement by different radioisotopic immunoassays. Here we evaluated the responses of six different commercial assays, radioisotopic and nonisotopic, with monoclonal or polyclonal antibodies in a series of 16 provocative tests (stimulation with clonidine) in short children. A wide range of discrepant values was obtained with the different kits. A cutoff of 10 micrograms/L produced discordance of diagnosis among assays for two children, whereas complete agreement was reached for a cutoff value of 7 micrograms/L. Parallelism tests performed with hGH international standard, pure recombinant hGH, and a serum with high hGH content suggest that heterogeneity of the antibodies used by the manufacturers, even among monoclonal antibodies, is the main source of discordant results. Cutoff values and reference values must be established separately for each method proposed for routine use.

1984 ◽  
Vol 104 (2) ◽  
pp. 172-176 ◽  
Author(s):  
J.M. Gertner ◽  
M. Genel ◽  
S.P. Gianfredi ◽  
R.L. Hintz ◽  
R.G. Rosenfeld ◽  
...  

2010 ◽  
Vol 20 (3) ◽  
pp. 239-244 ◽  
Author(s):  
Zida Wu ◽  
Emral Devany ◽  
Giovanna Balarini ◽  
Riia Junnila ◽  
Martin Bidlingmaier ◽  
...  

2014 ◽  
Vol 4 (1-2) ◽  
pp. 1-13 ◽  
Author(s):  
Hans-Peter Schwarz ◽  
Dorota Birkholz-Walerzak ◽  
Mieczyslaw Szalecki ◽  
Mieczyslaw Walczak ◽  
Corina Galesanu ◽  
...  

Author(s):  
F. Frankenne ◽  
J. Closset ◽  
F. Gomez ◽  
G. Pirens ◽  
J. Smal ◽  
...  

1993 ◽  
Vol 39 (8) ◽  
pp. 1620-1625 ◽  
Author(s):  
K Albertsson-Wikland ◽  
C Jansson ◽  
S Rosberg ◽  
A Novamo

Abstract We describe a time-resolved immunofluorometric assay (trIFMA) for human growth hormone (hGH), in which monoclonal antibody (mAb)-coated microtiter strip wells and a europium (Eu) chelate-labeled mAb are used. We compare the new trIFMA, in which two mAbs are used, with an immunoradiometric assay (IRMA) in which polyclonal antibodies are used. Serum samples (n = 185) from 36 children with various diagnoses were analyzed. In addition, 24-h profile samples (72 per child) from 39 children were analyzed. The trIFMA was more sensitive (detection limit, 0.03 mIU/L) than existing IRMAs. Both the intra- and interassay CVs were < or = 10.6% for hGH concentrations between 1 and 100 mIU/L. The trIFMA is technically simple and rapid, requires no centrifugation or separation reagent, and has a counting time of only 1 s per sample. In addition, the Eu label is nontoxic, presents no waste-disposal problems, and has a long shelf-life. Finally, the assay requires only small volumes of serum (25 muL), which is of considerable importance in pediatric use. The mAbs used for the trIFMA selectively bind the 22-kDa form of hGH, with the result that the assay detects about 80% of the amount detected by the polyclonal IRMA.


1983 ◽  
Vol 225 (2) ◽  
pp. 436-445 ◽  
Author(s):  
Natalio Vita ◽  
Edgardo Poskus ◽  
Clara Peña ◽  
Ana R. Pérez ◽  
Alejandro C. Paladini

Sign in / Sign up

Export Citation Format

Share Document