P181 Implantable cardioverter defibrillator and cardiac resynchronisation therapy use in New Zealand

2020 ◽  
Vol 41 (Supplement_1) ◽  
Author(s):  
F S Foo ◽  
M Lee ◽  
A J Kerr

Abstract Introduction The ANZACS-QI DEVICE registry is a national registry designed to collect data on all cardiac implantable electronic devices (CIED) implanted in New Zealand (NZ). This study aims to provide a contemporary analysis of the clinical characteristics and implant details of patients receiving implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy (CRT), including CRT-Pacemaker (CRT-P) and CRT-Defibrillator (CRT-D). Methods Complete datasets of ICD, CRT-D and CRT-P implants from the ANZACS-QI DEVICE registry from 1st January 2014 to 31st December 2017 were analysed.  Results A total of 1579 ICD implants were identified. Of the 1152 (73.0%) new implants, 565 (49.0%) were for primary prevention and 587 (51.0%) were for secondary prevention. The baseline demographics of both groups were similar, with a median age of 62 and predominantly male (79.2-81.4%), with European (63.7-66.8%) and Maori (21.1-24.8%) being the most common ethnicities. The mean BMI was 29.6-30.2 kg/m², with most patients (75.2-80.7%) being in sinus rhythm at the time of ICD implant. Compared to the secondary prevention group, the primary prevention group had more patients with a history of heart failure (80.4% vs 39.7%), worse heart failure symptoms (NYHA Class II-III 77.1% vs 47.3%), poorer left ventricular ejection fraction (LVEF) (mean 25.1% vs 30.3%) and the aetiology was more likely to be non-ischaemic (57.5% vs 44.2%). The mean QRS duration was longer (129.9ms vs 113.4ms), with a higher incidence of left bundle branch block (31.9% vs 16.0%) and a correspondingly higher rate of CRT-D implants (27.4% vs 8.3%).  In the 427 (27.0%) ICD replacements, over a mean duration of 6.27 years, 46.6% had delivered appropriate therapy (including 38.4% with appropriate ICD shocks) whilst 17.8% had delivered inappropriate therapy. Compared to primary prevention CRT-D (n = 155), patients receiving CRT-P (n = 175) were older (median age 74 vs 66) and more likely to be female (38.3% vs 19.4%). CRT-D patients had longer mean QRS duration (169.2ms vs 160.8ms) and poorer LVEF (mean 24.3% vs 28.7%). Conclusion This analysis provides contemporary data on ICD and CRT use in New Zealand. Primary prevention ICD patients were more likely to have a history of heart failure, worse heart failure symptoms, more prolonged QRS duration, left bundle branch block and poorer LV function compared to secondary prevention ICD. Compared to primary prevention CRT-D, patients receiving CRT-P were older and more likely to be female.

Heart ◽  
2018 ◽  
Vol 104 (18) ◽  
pp. 1529-1535 ◽  
Author(s):  
Sérgio Barra ◽  
Rui Providência ◽  
Serge Boveda ◽  
Rudolf Duehmke ◽  
Kumar Narayanan ◽  
...  

ObjectiveIn patients indicated for cardiac resynchronisation therapy (CRT), the choice between a CRT-pacemaker (CRT-P) versus defibrillator (CRT-D) remains controversial and indications in this setting have not been well delineated. Apart from inappropriate therapies, which are inherent to the presence of a defibrillator, whether adding defibrillator to CRT in the primary prevention setting impacts risk of other acute and late device-related complications has not been well studied and may bear relevance for device selection.MethodsObservational multicentre European cohort study of 3008 consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy and no history of sustained ventricular arrhythmias, undergoing CRT implantation with (CRT-D, n=1785) or without (CRT-P, n=1223) defibrillator. Using propensity score and competing risk analyses, we assessed the risk of significant device-related complications requiring surgical reintervention. Inappropriate shocks were not considered except those due to lead malfunction requiring lead revision.ResultsAcute complications occurred in 148 patients (4.9%), without significant difference between groups, even after considering potential confounders (OR=1.20, 95% CI 0.72 to 2.00, p=0.47). During a mean follow-up of 41.4±29 months, late complications occurred in 475 patients, giving an annual incidence rate of 26 (95% CI 9 to 43) and 15 (95% CI 6 to 24) per 1000 patient-years in CRT-D and CRT-P patients, respectively. CRT-D was independently associated with increased occurrence of late complications (HR=1.68, 95% CI 1.27 to 2.23, p=0.001). In particular, when compared with CRT-P, CRT-D was associated with an increased risk of device-related infection (HR 2.10, 95% CI 1.18 to 3.45, p=0.004). Acute complications did not predict overall late complications, but predicted device-related infection (HR 2.85, 95% CI 1.71 to 4.56, p<0.001).ConclusionsCompared with CRT-P, CRT-D is associated with a similar risk of periprocedural complications but increased risk of long-term complications, mainly infection. This needs to be considered in the decision of implanting CRT with or without a defibrillator.


2013 ◽  
Vol 2 (2) ◽  
pp. 91
Author(s):  
Antonio Sorgente ◽  
Riccardo Cappato ◽  
◽  

Cardiac resynchronisation therapy (CRT) is a well-established non-pharmacological treatment option for patients with refractory symptomatic heart failure (HF) already under optimal medical therapy. CRT is founded on the principle that interventricular conduction disturbances and more in particular left bundle branch block (LBBB) are deleterious to cardiac performance, and may contribute to the systolic and diastolic incompetency typical of patients with HF. Although CRT is associated with a not negligible percentage of non-response, all the international guidelines on chronic HF have extended their indications to CRT, also to patients with less symptomatic HF who are already showing signs of systolic dysfunction and interventricular dyssynchrony, without giving any substantial advice to reduce the number of failures of this therapy. This review seeks to point out the potential issues linked to CRT, with the aim of making a reappraisal of the clinical evidences supporting the current indications to CRT, and to figure out which type of research should be warranted in the field for the future to reduce the percentage of non-responders to this therapy.


2015 ◽  
Vol 1 (1) ◽  
pp. 35 ◽  
Author(s):  
Fang Fang ◽  
Zhou Yu Jie ◽  
Luo Xiu Xia ◽  
Liu Ming ◽  
Ma Zhan ◽  
...  

Chronic heart failure is still a major challenge for healthcare. Currently, cardiac resynchronisation therapy (CRT) has been incorporated into the updated guideline for patients with heart failure, left ventricular ejection fraction ≤35 % and prolonged QRS duration. With 20 years of development, the concept of ‘from bench to bedside’ has been illustrated in the field of CRT. Given the fact that the indications of CRT keep evolving, the role of CRT is not limited to the curative method for heart failure. We therefore summarise with the perspective of 5P medicine – preventive, personalised, predictive, participatory, promotive, to review the benefit of CRT in the prevention of heart failure in those with conventional pacemaker indications, the individualised assessment of patient’s selection, the predictor of responders of CRT, and the obstacles hindering the more application of CRT and the future development of this device therapy.


Heart ◽  
2011 ◽  
Vol 97 (13) ◽  
pp. 1041-1047 ◽  
Author(s):  
P. W. X. Foley ◽  
K. Patel ◽  
N. Irwin ◽  
J. E. Sanderson ◽  
M. P. Frenneaux ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document