scholarly journals Real-time cardiovascular magnetic resonance tissue characterisation in patients undergoing transcatheter aortic valve replacement

2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
SJ Backhaus ◽  
T Lange ◽  
BE Beuthner ◽  
R Topci ◽  
X Wang ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): German Research Foundation (DFG, CRC 1002, D1) Background Myocardial fibrosis is a major determinant of outcome in aortic stenosis (AS). Novel fast real-time (RT) cardiac magnetic resonance (CMR) mapping techniques allow comprehensive quantification of fibrosis but have not yet been compared against standard techniques and histology. Methods Patients with severe AS underwent CMR before (n = 110) and left ventricular (LV) endomyocardial biopsy (n = 46) at transcatheter aortic valve replacement (TAVR). Midventricular short axis (SAX) native, post-contrast T1 and extracellular volume fraction (ECV) maps were generated using commercially available MOLLI (native: 5(3)3, post-contrast: 4(1)3(1)2) and RT single-shot inversion recovery fast low-angle shot (FLASH) with radial undersampling. Focal late gadolinium enhancement was excluded from T1 and ECV regions of interest. ECV and LV mass were used to calculate LV matrix volumes. Variability and agreements were assessed between RT, MOLLI and histology using intraclass correlation coefficients, coefficients of variation and Bland Altman analyses. Results RT and MOLLI derived ECV were similar for midventricular SAX slice coverage (26.2 vs. 26.5, p = 0.073) and septal region of interest (26.2 vs. 26.5, p = 0.216). MOLLI native T1 time was in median 20 ms longer compared to RT (p < 0.001). Agreement between RT and MOLLI was best for ECV (ICC >0.91), excellent for post-contrast T1 times (ICC >0.81) and good for native T1 times (ICC >0.62). Diffuse collagen volume fraction by biopsies was in median 7.8%. ECV (RT r = 0.345, p = 0.039; MOLLI r = 0.40, p = 0.010) and LV matrix volumes (RT r = 0.45, p = 0.005; MOLLI r = 0.43, p = 0.007) were the only parameters associated with histology. Conclusions RT mapping offers fast and sufficient ECV and LV matrix volume calculation in AS. ECV and LV matrix volume represent robust and universally comparable parameters with associations to histologically assessed fibrosis and may emerge as potential targets for clinical decision making.

2021 ◽  
Vol 5 (2) ◽  
Author(s):  
Devesh Rai ◽  
Muhammad Waqas Tahir ◽  
Medhat Chowdhury ◽  
Hammad Ali ◽  
Rupinder Buttar ◽  
...  

Abstract Background The coronavirus disease 2019 (COVID-19) pandemic has resulted in drastic changes to the practice of medicine, requiring healthcare systems to find solutions to reduce the risk of infection. Using a case series, we propose a protocol for same-day discharge (SDD) for selected patients undergoing transcatheter aortic valve replacement (TAVR) using real-time remote cardiac monitoring. Six patients with severe symptomatic aortic stenosis underwent TAVR and were discharged on the same day. Case summary Six patients with symptomatic severe native or bioprosthetic aortic valve stenosis underwent a successful transfemoral TAVR using standard procedures, including the use of rapid atrial pacing to assess the need for permanent pacemaker implantation. Following TAVR, patients were monitored on telemetry in the recovery area for 3 h, ambulated to assess vascular access stability, and discharged with real-time remote cardiac monitoring if no new conduction abnormality was observed. The patients were seen by tele-visits within 2 days and 2 weeks after discharge. Discussion Amidst the COVID-19 pandemic, SDD following successful transfemoral TAVR may be feasible for selected patients and reduce potential COVID-19 exposure.


Sign in / Sign up

Export Citation Format

Share Document