333018F-Fluorodeoxyglucose Positron Emission Tomography Computed Tomography (PET/CT) for the diagnosis of prosthetic valve infective endocarditis (PVIE): a prospective multicenter study

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
M Philip ◽  
L Tessonnier ◽  
J Mancini ◽  
J L Mainardi ◽  
D Lussato ◽  
...  

Abstract Background and objectives 18F-FDG PET/CT has recently been added as a major criterion in the ESC 2015 infective endocarditis (IE) guidelines, but the value of this new diagnostic algorithm has never been prospectively assessed. Purposes 1. Primary objective: to assess the value of the new ESC criteria including 18F-FDG PET/CT in prosthetic valve infective endocarditis (PVIE). 2. Secondary objectives: to determine the reproducibility of 18F-FDG PET/CT; to assess its ability to predict embolic events. Methods Between 2014 and 2017, 175 patients with suspected PVIE were prospectively included in 3 French centers. After exclusion of patients with uninterpretable or not feasible PET/CT,115 patients were finally included in the analysis, including 91 definite IE and 24 rejected IE, as defined by an expert Consensus of Endocarditis Team after 3-month follow-up as Gold Standard Nuclear data were blindly analyzed by two independent nuclear medicine physicians. Patients follow-up was scheduled at one and three months after hospitalization Results Significant cardiac uptake by PET/CT (major criterion) was observed in 67 among 91 patients with definite PVIE and 6 patients with rejected IE (sensitivity 73.6%, specificity 75%, positive predictive value 91%, negative predictive value 42%). Considering cardiac uptake as a major criterion, the ESC 2015 classification increased the sensitivity of Duke criteria from 57 to 84% (p<0.001) but decreased its specificity from 84 to 70% (p<0.001). Intraobserver reproducibility of cardiac uptake evaluation was good (kappa = 0.84) but inter observer reproductibility was less satisfactory (kappa = 0.63). Embolic events occurred in 31 patients (27%) and were correlated with vegetation size by ECHO (p<0.001), Staphylococcus infection (p=0.003), and PET/CT cardiac uptake (p=0.02). Conclusion 1. the value of PET CT and ESC criteria is confirmed and may allow earlier diagnosis of PVIE 2. PET CT is associated with an increased risk of false positive results probably related to the technical improvements 3. Reproducibility of nuclear measurements seems unsatisfactory, justifying efforts to standardize PET studies interpretation 4. Our study describes for the first time a positive correlation between a positive PET/Ct and occurrence of embolic events, warranting additional studies.

Diagnostics ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 720
Author(s):  
Valentin Pretet ◽  
Cyrille Blondet ◽  
Yvon Ruch ◽  
Matias Martinez ◽  
Soraya El Ghannudi ◽  
...  

According to European Society of Cardiology guidelines (ESC2015) for infective endocarditis (IE) management, modified Duke criteria (mDC) are implemented with a degree of clinical suspicion degree, leading to grades such as “possible” or “rejected” IE despite a persisting high level of clinical suspicion. Herein, we evaluate the 18F-FDG PET/CT diagnostic and therapeutic impact in IE suspicion, with emphasis on possible/rejected IE with a high clinical suspicion. Excluding cases of definite IE diagnosis, 53 patients who underwent 18F-FDG PET/CT for IE suspicion were selected and afterwards classified according to both mDC (possible IE/Duke 1, rejected IE/Duke 0) and clinical suspicion degree (high and low IE suspicion). The final status regarding IE diagnosis (gold standard) was based on the multidisciplinary decision of the Endocarditis Team, including the ‘imaging specialist’. PET/CT images of the cardiac area were qualitatively interpreted and the intensity of each focus of extra-physiologic 18F-FDG uptake was evaluated by a maximum standardized uptake value (SUVmax) measurement. Extra-cardiac 18F-FDG PET/CT pathological findings were considered to be a possible embolic event, a possible source of IE, or even a concomitant infection. Based on the Endocarditis Team consensus, final diagnosis of IE was retained in 19 (36%) patients and excluded in 34 (64%). With a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and global accuracy of 79%, 100%, 100%, 89%, and 92%, respectively, PET/CT performed significantly better than mDC (p = 0.003), clinical suspicion degree (p = 0.001), and a combination of both (p = 0.001) for IE diagnosis. In 41 patients with possible/rejected IE but high clinical suspicion, sensitivity, specificity, PPV, NPV, and global accuracies were 78%, 100%, 100%, 85%, and 90%, respectively. Moreover, PET/CT contributed to patient management in 24 out of 53 (45%) cases. 18F-FDG PET/CT represents a valuable diagnostic tool that could be proposed for challenging IE cases with significant differences between mDC and clinical suspicion degree. 18F-FDG PET/CT allows a binary diagnosis (definite or rejected IE) by removing uncertain diagnostic situations, thus improving patient therapeutic management.


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Fabio Chirillo ◽  
Franco Boccaletto ◽  
Paola Pantano ◽  
Alessandro De Leo ◽  
Marta Possamai ◽  
...  

The diagnosis of infective endocarditis (IE) is sometimes difficult when there are discrepancies between blood cultures, transesophageal echocardiography (TEE) and clinical judgment. The aim of this study was to assess the incremental diagnostic value of 18 F-FDG-PET/CT in 45 consecutive patients (73% male, mean age 61 ± 26 years) with suspected IE and inconclusive tests at admission. In 28 patients (19 with a cardiac valvular (15) or nonvalvular (4) device) with blood cultures positive for germs typically involved in IE the initial TEE was negative or inconclusive. In 10 patients presenting with fever TEE identified cardiac lesion possibly related to IE (ruptured mitral chordae, thickened valve leaflet, thickened prosthetic annulus), but blood cultures were persistently negative. Finally, 7 patients had metastatic or embolic lesions and a predisposing cardiac condition, but TEE was negative. When previous unknown lesions detected by PET/CT were confirmed by succeeding examinations, they were considered true positives. When PET/CT was negative, it was compared with the final diagnosis that was defined according to the modified Duke criteria determined during a 6-month follow-up. Thirty patients had definite IE at the end of the follow-up, 3 had possible IE, and in 12 patients the diagnosis was rejected. Twenty-seven patients (60%) exhibited abnormal FDG uptake around the cardiac valves, and 12 (27%) had extracardiac accumulation. In 5 patients the initial negative TEE became positive a mean 5 ±7 days after PET/CT had been performed The sensitivity, specificity, positive predictive value, and negative predictive value of PET/CT were as follows (95% confidence interval): 87% (68% to 95%), 67% (38% to 87%), 84% (65% to 94%), and 71% (42% to 92%), respectively. Adding abnormal FDG uptake as a new major criterion significantly increased the sensitivity of the modified Duke criteria at admission (68% [53% to 82%] vs. 96% [88% to 99%], p = 0.01). This result was due to a significant reduction (p < 0.001) in the number of possible IE cases. In conclusion PET/CT increases the diagnostic accuracy for IE in the subset of patients with possible IE and may help to manage a challenging situation.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Philip ◽  
S Delcourt ◽  
S Cammilleri ◽  
F Gourriet ◽  
L Tessonnier ◽  
...  

Abstract Background and objectives 18F-FDG PET/CT has recently been added as a major criterion in the ESC 2015 infective endocarditis (IE) guidelines. We and others have demonstrated that18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) / computed tomography (CT) was useful in patients with suspected prosthetic valve and cardiac device IE. However, the sensitivity and specificity of ESC classification is unknown in patients with native valve endocarditis (NVE) as well as the clinical impact of PET findings. Purposes 1. Primary objective: To assess the value of the new ESC criteria including 18F-FDG PET/CT in native valve infective endocarditis (NVIE). 2. Secondary objectives: – to determine the usefulness of PET/CT concerning embolic or neoplastic detection. – to describe a new PET/CT feature, i.e. the diffuse splenic uptake. Methods Between 2012 and 2017, 75 patients with suspected NVIE were prospectively included, after exclusion of patients with uninterpretable or not feasible PET/CT. Using the expert consensus of the Endocarditis Team after a 3-month follow-up as gold standard, 63 IE were confirmed and 12 were rejected. Patients follow-up was scheduled at one and three months after hospitalization. Results Significant cardiac uptake by PET/CT (major criterion) was observed in 11 among 63 patients with definite NVIE and no patients with rejected IE (sensitivity 18%, specificity 100%). Among the 63 patients with a final diagnosis of NVE, a peripheral embolism or mycotic aneurysm was observed in 20 cases (32%). Considering this, the ESC 2015 classification increased the sensitivity of Duke criteria from 64 to 70% (p&lt;0.001) without no change on specificity (p&lt;0.001). Twenty-four patients (38%) were diagnosed with secondary infectious sites or infectious portal of entry. A diffuse splenic uptake was observed in 39 (52%) patients, including 37 (59%) of patients with a final diagnosis of NVE (specificity 83%). Conclusion 1. The value of 18F-FDG PET/CT in NVE diagnosis is poor (18% sensitivity) 2. Usefulness of PET/CT remains high when concerning embolic or neoplastic detection. 3. Our study describes for the first time in NVE a new potential endocarditis criterion, i.e. the presence of a diffuse splenic uptake on 18F-FDG PET/CT Diffuse splenic uptake Funding Acknowledgement Type of funding source: None


Author(s):  
F Selcuk Simsek ◽  
Muharrem cakmak ◽  
Duygu Kuslu ◽  
Tansel Balci ◽  
Erdal In ◽  
...  

IntroductionThere is no consensus about standardized uptake value maximum (SUVmax) cut-off value to characterize pleural thickening worldwide. Sometimes, this causes unnecessary invasive diagnostic procedures. Our first aim is to determine a cut-off value for SUVmax. Secondly, we try to answer this question “If we use this cut-off value together with morphological parameters, can we differentiate benign thickening from Malignant pleural mesothelioma (MPM) more accurately”.Material and methodsThirty-seven patients with performed 2-deoxy-2-[18F]-fluoro-D-glucose ([18F]FDG-PET/CT) before pleural biopsy included the study. All of patients had histopathologically proven primary pleural disease. Their [18F]FDG-PET/CT imaging reports were re-assessed. If patient’s SUVmax or size of the thickening was not mentioned in report, we calculated them with their [18F]FDG-PET/CT.ResultsAge, pleural effusion, size, and SUVmax were found a relationship with MPM. We found the size>14 mm, and SUVmax>4.0 as cut-off values for MPM. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for size>14 mm were found as 86.4%, 85.2%, 82.6%, 88.5%, respectively. For SUVmax>4.0; sensitivity, specificity, PPV, NPV were 90.9%, 87.0%, 85.1%, 92.2%, respectively.ConclusionsIf a patient has SUVmax>4.0 and/or size>14 mm, the risk of MPM is high. These patients should be undergone biopsy. If patient’s SUVmax<4.0, size<14 mm and does not have pleural effusion, he/she has low risk for MPM. These patients can be undergone to the follow-up. If a patient's SUVmax<4, Size<14, and has pleural effusion MPM risk is approximately 4%. These patients can be undergone biopsy/cytology/follow-up. Novel studies are needed for these patients.


2021 ◽  
Vol 5 (5) ◽  
Author(s):  
Elisa Ricciardi ◽  
Alessandro Moscatelli ◽  
Marco Berruti ◽  
Maria Isabella Donegani ◽  
Malgorzata Karolina Mikulska ◽  
...  

Abstract Background  European Society of Cardiology 2015 guidelines approved 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) as a useful diagnostic imaging technique in prosthetic valve endocarditis (PVE) and recent evidence seems to suggest a role of nuclear imaging in the follow-up of cardiovascular infections, but nowadays there are no sufficient data available. Case summary  A 67-year-old male presented with fever, weight loss, and fatigue. His medical history included ulcerative colitis and a previous Bentall-De Bono surgical procedure in 2014. A previous recent hospitalization to a small community hospital did not reveal a clear aetiology for the fever: transeosophageal echocardiography showed dubious peri-prosthetic tissue alterations, interpreted as post-surgical fibrosis; consequently, the patient was discharged with steroid therapy. At admission in our ward, we repeated transoesophageal echocardiography that confirmed the peri-prosthetic alterations. Moreover, 18F-FDG PET/CT showed two hypermetabolic areas, one around the prosthetic tube in the aortic bulb and the other in relation with the prosthetic aortic valve. Serological test was positive for Coxiella burnetii infection with consequent beginning of a targeted antimicrobial therapy with oral doxicycline and hydroxychloroquine. Echocardiography, serology, and 18F-FDG PET/CT follow-up demonstrated a progressive response to treatment and clinical conditions of the patient gradually improved. Discussion  According to guidelines, 18F-FDG PET/CT can be used in ambiguous PVE to improve diagnostic accuracy of standard techniques. In this case, 18F-FDG PET/CT combined with echocardiography and serological tests is used not only to better define diagnosis but also for treatment response monitoring during follow-up.


2015 ◽  
Vol 74 (Suppl 2) ◽  
pp. 519.2-519
Author(s):  
G. Pazzola ◽  
M. Casali ◽  
F. Muratore ◽  
N. Pipitone ◽  
L. Boiardi ◽  
...  

2021 ◽  
Vol 15 (1) ◽  
pp. 14
Author(s):  
Nidaa Mikail ◽  
Fabien Hyafil

Infective endocarditis (IE) is a life-threatening disease with stable prevalence despite prophylactic, diagnostic, and therapeutic advances. In parallel to the growing number of cardiac devices implanted, the number of patients developing IE on prosthetic valves and cardiac implanted electronic device (CIED) is increasing at a rapid pace. The diagnosis of IE is particularly challenging, and currently relies on the Duke-Li modified classification, which include clinical, microbiological, and imaging criteria. While echocardiography remains the first line imaging technique, especially in native valve endocarditis, the incremental value of two nuclear imaging techniques, 18F-fluorodeoxyglucose positron emission tomography with computed tomography (18F-FDG-PET/CT) and white blood cells single photon emission tomography with computed tomography (WBC-SPECT), has emerged for the management of prosthetic valve and CIED IE. In this review, we will summarize the procedures for image acquisition, discuss the role of 18F-FDG-PET/CT and WBC-SPECT imaging in different clinical situations of IE, and review the respective diagnostic performance of these nuclear imaging techniques and their integration into the diagnostic algorithm for patients with a suspicion of IE.


Sign in / Sign up

Export Citation Format

Share Document