P971Impact of treatment strategy on 1-year outcome for Left Main trifurcation lesions

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
K Tani ◽  
S Mitomo ◽  
K Tanaka ◽  
S Tahara ◽  
S Nakamura

Abstract Background/Introduction Limited data exist regarding procedural strategy and clinical outcomes after percutaneous coronary intervention (PCI) for unprotected left main (LM) trifurcation lesion. Purpose The aim of this study is to evaluate 1-year clinical outcomes after LM trifurcation PCI comparing different strategies in kissing balloon inflation (KBI). Methods From 1, January, 2011 to 31, March, 2017, patients who underwent LM trifurcation PCI with second generation drug-eluting stent in our center were retrospectively analyzed. They were categorized into single-stent KBT group (KBT in left anterior descending artery [LAD] and left circumflex artery [LCX], or LAD and high lateral branch [HL]) and no-KBT group. Primary endpoint is restenosis in the lesions. Results Among 1301 patients who underwent LM PCI during the study period, 163 patients (12.5%) had a trifurcation lesion. Regarding the number of stents used for the lesions, 1, 2 and 3 stents were used in 75.4%, 22.0% and 2.5%, respectively. Median follow-up period of LM trifurcation patients was 265 days (interquartile range: 81–564). In the no-KBT group (64 patients), 19 patients experienced restenosis of HL and LCX (HL: 8 patients, LCX: 0 patient, and both: 11 patients). In the KBT-group, KBT for LAD and LCX was performed in 47 patients, and of them, 19 patients experienced restenosis of LM-LAD, HL and LCX (HL: 12 patients, LCX: 6 patients and all: 1 patient). On the other hand, in 9 patients with KBT for LAD and HL, there were no restenosis cases at 1-year follow-up. There was no statistically significant difference in restenosis rate between the no-KBI and KBT group (29.6% vs. 40.4%, p=0.69). Restenosis rates in each segments Conclusion After LM trifurcation PCI, restenosis rate at 1-year follow-up was high, and no difference between no-KBT and KBT group overall. However, there was no restenosis case in patients with KBT for LAD and HL.

Author(s):  
Jun-Qing Gao

Objective: To evaluate the clinical efficacy of a drug-eluting stent (DES) combined with a drug-coated balloon (DCB)in the treatment of left main coronary artery bifurcation lesions.Methods: A retrospective analysis was conducted on the clinical data of eight patients with left main coronary arterybifurcation lesions treated with a DES combined with a DCB who were admitted to our hospital from July 2016 to July2017. These eight patients all underwent DES treatment for their left main coronary artery and left anterior descendingcoronary artery lesions, and DCB treatment at the ostium of the left circumflex artery; six of the patients underwentsurgical procedures under the guidance of intravascular ultrasonography. Immediate postoperative angiography wasused to evaluate the patency of the diseased vessels, and the restenosis rate at the 6-month follow-up after the operationand the incidence of serious clinical events within 6 months were assessed as well.Results: The use of a DES combined with a DCB in the treatment of left main coronary artery bifurcation lesions hada low restenosis rate (left main coronary artery (8.4 ± 5.3)%, left anterior descending coronary artery (18.2 ± 5.0)%,left circumflex artery (30.5 ± 16.5)%). No serious clinical events occurred in any patients.Conclusion: A DES combined with a DCB is a safe and effective interventional treatment for left main artery coronarybifurcation lesions.


Vascular ◽  
2013 ◽  
Vol 22 (3) ◽  
pp. 214-217 ◽  
Author(s):  
Nidal Abi Rafeh ◽  
Faisal B Saiful ◽  
Georges Khoueiry ◽  
Mohammad Zgheib ◽  
Salman Arain

A 75-year-old woman with past medical history of coronary bypass, atrial fibrillation, mitral valve repair undergoes percutaneous coronary intervention of left circumflex artery with a drug eluting stent. An Angio-Seal vascular closure device was used post procedure to obtain hemostasis. Shortly after deployment, frank bleeding was observed necessitating manual compression at the arteriotomy site. After hemostasis was achieved, the right lower extremity was found to be pale, bluish with feeble pulses. Doppler ultrasound was emergently performed revealing decreased blood flow after mid superficial femoral artery (SFA) and an echo lucent object lodged luminally in the SFA. Patient was urgently taken to the vascular laboratory where an Angio-Seal device, including the collagen plug and anchor, was successfully removed endovascularly patient made full recovery and was discharged home the following day.


2021 ◽  
Vol 11 (2) ◽  
pp. 99-108
Author(s):  
Yusuke Watanabe ◽  
Satoru Mitomo ◽  
Ozan M. Demir ◽  
Kuan-Liang Liu ◽  
Ying-Chang Tung ◽  
...  

<b><i>Aims:</i></b> We assessed clinical outcomes after percutaneous coronary intervention (PCI) for unprotected left main coronary artery (ULMCA) distal bifurcation lesions using drug-eluting stents (DES) in hemodialysis (HD) patients compared to non-HD patients. <b><i>Methods and Results:</i></b> We identified 1,858 consecutive patients who underwent PCI for ULMCA distal bifurcation lesions at 4 high-volume centers in Japan, Italy, and Taiwan between January 2005 and December 2015. Of them, 1,416 patients were treated with DES including 113 HD patients and 1,303 non-HD patients. The primary end point was target lesion failure (TLF) defined as a composite of cardiac death, target lesion revascularization (TLR), and myocardial infarction. HD patients were more likely to be younger and have diabetes mellitus, dyslipidemia, peripheral artery disease, lower ejection fraction, and higher EuroSCORE. TLF rate at 3 years was significantly higher in HD group than in non-HD group (adjusted hazard ratio [HR] 2.43 [1.75–3.38], <i>p</i> &#x3c; 0.001). Cardiac mortality and TLR rate were also significantly higher in HD group than in non-HD group (adjusted HR 3.85 [2.34–6.34], <i>p</i> &#x3c; 0.001, and HR 2.10 [1.41–3.14], <i>p</i> &#x3c; 0.001, respectively). <b><i>Conclusions:</i></b> HD was strongly associated with adverse cardiac events after PCI for ULMCA distal bifurcation lesions with DES.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
J C Choe ◽  
K S Cha ◽  
J Y Shin ◽  
J Ahn ◽  
J S Park ◽  
...  

Abstract Background The true benefit of biodegradable polymer drug-eluting stent (BP-DES) over second-generation durable polymer drug-eluting stent (DP-DES) expected to be represented during late period of follow-up after percutaneous coronary intervention (PCI), but prior meta-analysis only evaluated short-term outcomes. Purpose We aimed to compare the long-term clinical outcomes after PCI with BP-DES versus second-generation DP-DES by a meta-analysis of randomized controlled trials. Methods Randomized controlled trials comparing BP-DES with second-generation DP-DES implantations were searched through PubMed, MEDLINE, EMBASE, and Cochrane databases. All-cause death, cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), target lesion revascularization (TLR), and definite/probable stent thrombosis (ST) were compared between the groups. In addition, a landmark analysis with the landmark set at 1-year and a subgroup analysis based on stent characteristics were performed. Results Fifteen trials that included a total of 21311 randomized patients with at least 2 years follow-up were analyzed. At a median follow-up of 4.2 years, no significant differences in the risks of all-cause death (odds ratio [OR] 1.03, 95% confidence interval [CI] 0.94–1.14), cardiac death (OR 1.03, 95% CI 0.88–1.20), MI (OR 0.90, 95% CI 0.79–1.01), TVR (OR 0.96, 95% CI 0.82–1.12), TLR (OR 0.97, 95% CI 0.85–1.11), and definite/probable ST (OR 0.84, 95% CI 0.67–1.05) were found between the groups. In the 1-year landmark analysis, the rates of all-cause death (OR 1.04, 95% CI 0.93–1.17), cardiac death (OR 1.11, 95% CI 0.92–1.36), MI (OR 0.94, 95% CI 0.79–1.13), TVR (OR 0.95, 95% CI 0.73–1.23), TLR (OR 1.00, 95% CI 0.80–1.24), and definite/probable ST (OR 0.94, 95% CI 0.67–1.31) were similar between the groups. There were comparable rates of any study endpoints between the groups regardless of stent platform (stainless steel vs. alloy), the polymer degradation period (<6 months vs. >6 months) or the drug release duration (<6 months vs. >6 months) of BP-DES, or the DAPT duration (≥6 months vs. ≥12 months). However, the use of BP-DES with sirolimus eluting (OR 0.82, 95% CI 0.70–0.97), circumferential drug distribution (OR 0.79, 95% CI 0.65–0.96), thin strut (defined as <100μm; OR 0.83, 95% CI 0.70–0.97), or ultrathin strut (defined as <70μm; OR 0.78, 95% CI 0.64–0.94) were associated with lower rates of MI than did second-generation DP-DES. Moreover, BP-DES with circumferential drug distribution (OR 0.82, 95% CI 0.69–0.98) was predictive for reduced rates of TVR. Clinical outcomes Conclusions In this meta-analysis, long-term clinical outcomes were equivalent between BP-DES and second-generation DP-DES implantations. However, among BP-DESs, the improved risks of MI in those with sirolimus eluting, circumferential drug distribution, thin strut, or ultrathin strut and decreased rates of TVR in those with circumferential drug distribution were noted.


2014 ◽  
Vol 6 (2) ◽  
pp. 107-111
Author(s):  
S Munwar ◽  
AHMW Islam ◽  
S Talukder ◽  
AQM Reza ◽  
T Ahmed ◽  
...  

Background: Aim of the study was to evaluate the primary procedural success of percutaneous coronary intervention of unprotected left main coronary artery stenosis using either Bare-metal stents or drug eluting stent. Methods: Total 33 patients were enrolled in this very preliminary non-randomized prospective cohort study. Among them, Male: 25 and Female: 8. Total 35 stents were deployed. Mean age were for Male: 59 yrs, for Female: 62 yrs. Associated coronary artery diseases risk factors were dyslipidemia, High Blood pressure, Diabetes Mellitus, Positive family history for coronary artery diseases and smoking. Results: Among the study group; 26 (78%) were Dyslipidemic, 24(70%) were hypertensive; 17 (51.5%) patients were Diabetic, 11(33%) were smoker and 7(21%) patients had family history of Ischaemic heart disease. Female patients were more obese (BMI M 26: F 27) and developed coronary artery diseases in advance age. Common stented territory were left main: 20 (60%), Left main to left anterior descending artery 7 (22%) and Left main to left circumflex artery 6 (18%). Average length and diameter of stent was 3.5 and 18 mm respectively. Stent used: Bare Metal Stent 5 (15%), Drug Eluting Stent: 28 (85%). Among the different Drug Eluting Stents, Everolimus eluting stents were 11 (39.3%), Sirolimus eluting 10(35.7%), Paclitaxel eluting 3 (10.7%), Biolimus eluting 3 (10.7%) and Zotarolimus eluting1 (3.6%). In the present study, overall survival outcome was 94% (31 patient), mortality of cardiac cause 3% (1 patient) and 1 patient (3%) died of hepatocellular carcinoma. Conclusion: Our study has shown that percutaneous coronary intervention of the unprotected left main is a safe and effective alternative to Coronary Artery Bypass Graft (CABG). DOI: http://dx.doi.org/10.3329/cardio.v6i2.18349 Cardiovasc. j. 2014; 6(2): 107-111


Sign in / Sign up

Export Citation Format

Share Document