scholarly journals Ten-year experience of the thoraco-abdominal aortic aneurysm treatment using a hybrid thoracic endovascular aortic repair†

2018 ◽  
Vol 26 (6) ◽  
pp. 951-956 ◽  
Author(s):  
Takashi Shuto ◽  
Tomoyuki Wada ◽  
Shinji Miyamoto ◽  
Noritaka Kamei ◽  
Norio Hongo ◽  
...  
2021 ◽  
Vol 14 (12) ◽  
pp. e246798
Author(s):  
Sho Takagi ◽  
Yoshihiro Goto ◽  
Junji Yanagisawa ◽  
Akio Nakasu

Stent graft collapse due to aortic dissection is an extremely rare event. Although endovascular aneurysm repair (EVAR) and thoracic endovascular aortic repair (TEVAR) are increasingly being performed, various complications can occur. We report a case of collapse of a stent graft, which was used to repair an abdominal aortic aneurysm (AAA) after TEVAR for thoracic aortic aneurysm (TAA). A 72-year-old man with a 77 mm AAA and 60 mm TAA underwent EVAR and a TEVAR 2 months later, respectively. CT performed after the TEVAR showed thoracic aorta dissection with associated AAA stent graft collapse. The graft collapsed was due to superior mesenteric artery obstruction. An emergency TEVAR was performed, and the procedure improved the collapsed graft; however, the endoleak of the AAA stent graft persisted. The AAA expanded over several days, warranting an open repair. Our case provides an insight into the cautionary indications for endovascular therapy.