scholarly journals Chlortetracycline, Oxytetracycline, and Tetracycline in Edible Animal Tissues, Liquid Chromatographic Method: Collaborative Study

1996 ◽  
Vol 79 (2) ◽  
pp. 405-417 ◽  
Author(s):  
James D MacNeil ◽  
Valerie K Martz ◽  
Gary O Korsrud ◽  
Craig D C Salisbury ◽  
Hisao Oka ◽  
...  

Abstract Thirteen laboratories analyzed samples of edible animal tissues for tetracycline residues. The method included extraction of analytes into buffer, elution from a C18 solid-phase extraction (SPE) cartridge, and reversed-phase liquid chromatographic (LC) analysis, including use of a confirmation column. An additional laboratory, using an alternative LC assay based on a different sample cleanup, also analyzed the samples. Results showed the 2 methods are comparable. The LC method for determination of cholortetracycline, oxytetracycline, and tetracycline in edible animal tissues has been adopted by AOAC INTERNATIONAL. Results from 13 laboratories indicate that the method under study provides generally better results at the higher concentrations tested than at concentrations near the detection limit and that there is less problem with interferences in muscle tissue than in kidney. The method can achieve reliable results for analytes and matrixes studied at concentrations from 0.1 to 0.6 ppm and above, depending on the analyte-matrix combination, with generally better performance to be expected with muscle than with kidney. The poorer performance for fortified samples, particularly kidney, was attributed to additional homogenization steps required to prepare these samples. Recovery of analytes from different

1995 ◽  
Vol 78 (5) ◽  
pp. 1131-1133
Author(s):  
Alan R Hanks

Abstract A liquid chromatographic method for determination of dithianon in technical products and formulations was evaluated by 22 laboratories participating in a collaborative study. Data received from 19 laboratories were used in the statistical analysis. The study included 3 technical grade materials, 1 suspension concentrate, and 1 wettable powder. Dithianon is determined by reversed-phase liquid chromatography on a C18 column with a mobile phase of acetonitrile and water. Detection at 254 nm with peak area measurements is used with an external standard for quantitation of dithianon. The liquid chromatographic method for determination of dithianon in technical products and formulations has been adopted first action by AOAC INTERNATIONAL.


1998 ◽  
Vol 81 (2) ◽  
pp. 341-343
Author(s):  
Alan R Hanks ◽  
◽  
J Abedi ◽  
E De Aguila ◽  
F Bodzian ◽  
...  

abstract A liquid chromatographic method for determining thiodicarb in technical products and formulations was evaluated by 25 participants from 19 laboratories. Data from 19 laboratories were used in statistical analysis to characterize method performance.Two technical materials, a suspension concentrate, a wettable powder, and a water dispersable granule were analyzed. Thiodicarb was determined by reversed-phase liquid chromatography using a mobile phase of methanol and water. Chromatography was performed on a C8 column with detection at 254 nm. Quantitation was achieved by using an internal standard and peak area ratios.


Author(s):  
Charles M.G Frijters ◽  
Coosje J Tuijn ◽  
Frans J Hoek ◽  
Albert K Groen ◽  
Ronald P.J Oude Elferink ◽  
...  