scholarly journals Reversed-Phase Ion-Pair Liquid Chromatographic Determination of Chlorophacinone and Diphacinone in Steam- Rolled Oat Baits and Steam-Rolled Oat/Wax Baits

1998 ◽  
Vol 81 (2) ◽  
pp. 349-358 ◽  
Author(s):  
Thomas M Primus ◽  
Doreen L Griffin ◽  
Stephanite A Volz ◽  
John J Johnston

abstract A reversed-phase ion-pair liquid chromatographic (LC) method was developed for analysis of steam-rolled oat (SRO) baits fortified with either chlorophacinone or diphacinone. Baits were prepared with and without paraffin wax. Chlorophacinone or diphacinone was extracted from wax-free SRO baits with 5 mM tetrabutylammonium phosphate methanolic ion-pairing solution. Wax baits were initially extracted with petroleum ether and then cleaned up by liquid extraction into methanolic ion-pairing solution containing 20% water. SRO extracts were analyzed with reversed-phase ion-pair LC. Chlorophacinone and diphacinone were quantified by UV absorption at 325 nm. Recoveries from SRO fortified with chlorophacinone at 25 and 150 μg/g were 90.7 and 90.8%, respectively, whereas for diphacinone at the same levels, recoveries were 93.5 and 92.3%, respectively. Recoveries from wax baits fortified at 25 and 75 μg/g chlorophacinone were 98.5 and 100%, respectively, whereas for diphacinone at the same levels, recoveries were 93.6 and 98.0%, respectively. Method limits of detection for chlorophacinone and diphacinone in SRO baits were estimated to be 1.0 and 0.76 μg/g, respectively. Method limits of detection for chlorophacinone and diphacinone in wax baits were estimated to be 4.2 and 2.8 μg/g, respectively.

2001 ◽  
Vol 84 (3) ◽  
pp. 634-639 ◽  
Author(s):  
John J Johnston ◽  
Margaret J Goodall ◽  
Jerome C Hurley ◽  
Christi A Yoder ◽  
Lowell A Miller

Abstract Liquid chromatographic (LC) methods were developed for quantitating the potential avian contraceptive DiazaCon in quail feed and serum. DiazaCon was extracted from ground quail feed with basic n-butyl chloride. The n-butyl chloride extract was evaporated to dryness. The DiazaCon residues were dissolved in an aqueous methanolic ion pairing solution and quantitated by LC at 206 nm. Avian sera was combined with an equal volume of a pH 4 aqueous solution of ion pairing reagent and filtered to remove interfering proteins. DiazaCon was quantitated by LC. Mean recoveries for 500 and 2000 ppm fortified feed were 89.1 and 91.0%, respectively. The mean recovery for sera fortified at 5 levels ranging from 35 to 2000 ppm was 84.9%. Method limits of detection were approximately 14 and 13 ppm for feed and sera, respectively.


2002 ◽  
Vol 85 (4) ◽  
pp. 901-905 ◽  
Author(s):  
Joseph Ziqi Zhou ◽  
Ted Waszkuc ◽  
Spiro Garbis ◽  
Felicia Mohammed

Abstract A simple and reliable liquid chromatographic method was developed for the determination of S-adenosyl-L-methionine (SAM) in dietary supplement tablets. SAM in products was extracted with a phosphate buffer and separated from the mixture on a reversed-phase C8 column by ion-pair chromatography. A gradient mobile phase containing phosphate buffer, sodium octanesulfonate as the ion-pair reagent, and acetonitrile at a flow rate of 1.2 mL/min was used in the analysis. The UV detection wavelength was set at 257 nm. The calibration curve was linear over a range of 75–375 μg/mL for the SAM active ion with R2 = 0.9999. Replicate tests indicated good reproducibility of the method with a relative standard deviation of 0.9% (n = 8). The multiple extractions and recoveries from fortified products showed the high accuracy of the analysis. The use of the acidic buffer for SAM extraction and elution and the use of a fresh standard for each calibration to counteract the instability of the SAM compound significantly improved the accuracy of the method.


Sign in / Sign up

Export Citation Format

Share Document