scholarly journals Determination of Ochratoxin A in Currants, Raisins, Sultanas, Mixed Dried Fruit, and Dried Figs by Immunoaffinity Column Cleanup with Liquid Chromatography: Interlaboratory Study

2003 ◽  
Vol 86 (6) ◽  
pp. 1164-1171 ◽  
Author(s):  
Susan J MacDonald ◽  
Sharron Anderson ◽  
Paul Brereton ◽  
Roger Wood ◽  
G Barrett ◽  
...  

Abstract An interlaboratory study was performed on behalf of the Food Standards Agency to evaluate the effectiveness of an affinity column cleanup liquid chromatographic (LC) method for the determination of ochratoxin A in a variety of dried fruit at European regulatory limits. To ensure homogeneity before analysis, laboratory samples are normally slurried with water in the ratio of 5 parts fruit to 4 parts water, and test materials in this form were used in the study. The test portion was extracted with acidified methanol. The extract was filtered, diluted with phosphate-buffered saline, and applied to an affinity column. The column was washed and ochratoxin A was eluted with methanol. Ochratoxin A was quantified by reversed-phase LC. The use of post-column pH shift to enhance the fluorescence of ochratoxin A by the addition of 1.1M ammonia solution to the column eluant is optional. Determination was by fluorescence. Currants, sultanas, raisins, figs, and mixed fruit (comprising dried pineapple, papaya, sultanas, prunes, dates, and banana chips), both naturally contaminated and blank (very low level), were sent to 24 collaborators in 7 European countries. Participants were asked to spike test portions of all test samples at a level equivalent to 5 ng/g ochra toxin A. Average recoveries ranged from 69 to 74%. Based on results for 5 naturally contaminated test samples (blind duplicates) the relative standard deviation for repeatability (RSDr) ranged from 4.9 to 8.7%, and the relative standard deviation for reproducibility (RSDR)rangedfrom14to28%. The method showed acceptable within-and be-tween-laboratory precision for all 5 matrixes, as evidenced by HORRAT values <1.3.

2005 ◽  
Vol 88 (6) ◽  
pp. 1733-1740 ◽  
Author(s):  
Susan J MacDonald ◽  
Sharron Anderson ◽  
Paul Brereton ◽  
Roger Wood ◽  
Andrew Damant ◽  
...  

Abstract An interlaboratory study was performed on behalf of the UK Food Standards Agency to evaluate the effectiveness of an affinity column cleanup liquid chromatography (LC) method for the determination of zearalenone (ZON) in a variety of cereals and cereal products at proposed European regulatory limits. The test portion is extracted with acetonitrile:water. The sample extract is filtered, diluted, and applied to an affinity column. The column is washed, and ZON is eluted with acetonitrile. ZON is quantified by reversed-phase LC with fluorescence detection. Barley, wheat and maize flours, polenta, and a maize-based baby food naturally contaminated, spiked, and blank (very low level) were sent to 28 collaborators in 9 European countries and 1 collaborator in New Zealand. Participants were asked to spike test portions of all samples at a ZON concentration equivalent to 100 μg/kg. Average recoveries ranged from 91–111%. Based on results for 4 artificially contaminated samples (blind duplicates) and 1 naturally contaminated sample (blind duplicate), the relative standard deviation for repeatability (RSDr) ranged from 6.9–35.8%, and the relative standard deviation for reproducibility (RSDR) ranged from 16.4–38.2%. The method showed acceptable within- and between-laboratory precision for all 5 matrixes, as evidenced by HorRat values <1.7.


2005 ◽  
Vol 88 (2) ◽  
pp. 526-535 ◽  
Author(s):  
Hamide Z Senyuva ◽  
John Gilbert

Abstract An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 and total aflatoxins in hazelnut paste at European regulatory limits. The test portion was extracted with methanol–water (6 + 4). The extract was filtered, diluted with phosphate-buffered saline (PBS) solution to a specified solvent concentration, and applied to an immunoaffinity column containing antibodies specific to aflatoxins. The aflatoxins were removed from the immunoaffinity column with methanol, and then quantified by reversed-phase LC with post-column derivatization (PCD) involving bromination. The PCD was achieved with electrochemically generated bromine (Kobra Cell®) followed by fluorescence detection (except for one participant who used pyridinum hydrobromide perbromide for bromination). Hazelnut paste, both naturally contaminated with aflatoxins and blank (<0.1 ng/g) for spiking by participants with aflatoxins, was sent to 14 collaborators in Belgium, The Netherlands, Spain, Turkey, the United Kingdom, and the United States. Test portions were spiked at levels of 4.0 and 10.0 ng/g for total aflatoxins by participants using supplied total aflatoxins standards. Recoveries for total aflatoxins and aflatoxin B1 averaged from 86 to 89%. Based on results for naturally contaminated samples (blind duplicates at 3 levels ranging from 4.0 to 11.8 ng/g total aflatoxins), the relative standard deviation for repeatability (RSDr) ranged from 2.3 to 3.4% for total aflatoxins and from 2.2 to 3.2% for aflatoxin B1. The relative standard deviation for reproducibility (RSDR) ranged from 6.1 to 7.0% for total aflatoxins and from 7.3 to 7.8% for aflatoxin B1. The method showed exceptionally good within-laboratory and between-laboratory precision for hazelnut paste, as evidenced by HORRAT values, which in all cases were significantly below target levels, the low levels of determination for both aflatoxin B1 and total aflatoxins.


2003 ◽  
Vol 86 (2) ◽  
pp. 367-374 ◽  
Author(s):  
Allan R Brause ◽  
David C Woollard ◽  
Harvey E Indyk ◽  
J Acar ◽  
K Adadevoh ◽  
...  

Abstract A interlaboratory study was conducted to evaluate a liquid chromatographic (LC) procedure for the determination of total vitamin C in foods at levels of 5–60 mg/100 g. Emphasis was placed on fruit juices, although selected foods were also included in the study. Following dissolution of sample in water, endogenous dehydroascorbic acid was converted to ascorbic acid by precolumn reduction with dithiothreitol at neutral pH. Total ascorbate was determined by C18 reversed-phase LC with a phosphate eluent at pH 2.5, incorporating dithiothreitol to maintain vitamin C in the reduced form, and UV detection at 254 nm. Seven types of fruit juices and foods were tested by 19 collaborators in 7 countries. Three duplicate juices and foods met the criteria for Youden pairs and yielded repeatability relative standard deviation of 5.80–14.66%. Reproducibility relative standard deviation ranged from 6.36 to 35.54% (n = 10) with HORRAT values of 0.82–4.04. The LC method is suitable for routine use in fruit products and foods containing >5 mg/100 g vitamin C and is recommended for further validation by AOAC INTERNATIONAL and International Fruit Juice Union.


2005 ◽  
Vol 88 (3) ◽  
pp. 773-779 ◽  
Author(s):  
Eugênia Azevedo Vargas ◽  
Eliene Alves dos Santos ◽  
Alain Pittet ◽  
T B S Corrêa ◽  
A P P da Rocha ◽  
...  

Abstract A collaborative study was conducted to evaluate a method using immunoaffinity column cleanup with liquid chromatography (LC) for the determination of ochratoxin A (OTA) in green coffee at levels that could be included in possible future regulations of the European Union. The test portion was extracted with methanol–3% aqueous sodium hydrogen carbonate solution (50 + 50, v/v). The extract was filtered, and the filtrate was diluted with phosphate-buffered saline and applied to an immunoaffinity column containing antibodies specific for OTA. After washing, the toxin was eluted from the column with methanol and quantified by LC with fluorescence detection. Pairs of 4 homogeneous noncontaminated and naturally contaminated materials (mean levels of <0.12, 2.44, 5.15, and 13.46 ng/g) and blank samples (<0.12 ng/g) for spiking were sent to 20 participant laboratories from 8 countries. The materials were analyzed according to the method description and all difficulties encountered in the analysis were reported. Statistical analysis was carried out according to the Harmonized Protocol of the International Union of Pure and Applied Chemistry. The relative standard deviation for repeatability (RSDr) ranged from 7.42 to 20.94%, and the relative standard deviation for reproducibility (RSDR) ranged from 16.34 to 29.17%. The method showed acceptable within-laboratory and between-laboratories precision for green coffee materials, as evidenced by HorRat values of ≤0.85, at the studied range, for spiked and naturally contaminated materials. The mean recovery was 92.8% for green coffee material spiked with OTA at a level of 4.82 ng/g.


2006 ◽  
Vol 89 (4) ◽  
pp. 1012-1020 ◽  
Author(s):  
Joerg Stroka ◽  
Michelle Derbyshire ◽  
Carsten Mischke ◽  
Massimo Ambrosio ◽  
Katy Kroeger ◽  
...  

Abstract An interlaboratory study was conducted for the determination of deoxynivalenol in baby food and animal feed by high-performance liquid chromatography with UV detection. The study included 14 participants representing a cross section of industry, official food control, and research facilities. Mean recoveries reported ranged from 89% (at 120 g/kg) to 85% (at 240 g/kg) for baby food and from 100% (at 200 g/kg) to 93% (at 400 g/kg) for animal feed. On the basis of the results for spiked samples (blind duplicates at 2 levels), as well as those for naturally contaminated samples (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) in analyses of baby food ranged from 6.4 to 14.0% and in analyses of animal feed, from 6.1 to 16.5%. The relative standard deviation for reproducibility (RSDR) in analyses of baby food ranged from 9.4 to 19.5% and in analyses of animal feed, from 10.5 to 25.2%. The HorRat values ranged from 0.4 to 1.0 and from 0.7 to 1.3, for baby food and animal feed, respectively. The method showed acceptable performance for within-laboratory and between-laboratory precision for each matrix, as required by European legislation.


2001 ◽  
Vol 84 (2) ◽  
pp. 444-450 ◽  
Author(s):  
A Catherine Entwisle ◽  
Alison C Williams ◽  
Peter J Mann ◽  
Joanne Russell ◽  
Philip T Slack ◽  
...  

Abstract A collaborative study was conducted to evaluate a liquid chromatography (LC) method for ochratoxin A using sequential phenyl silane and immunoaffinity column cleanup. The method was tested at 3 different levels of ochratoxin A in roasted coffee, which spanned the range of possible future European regulatory limits. The test portion was extracted with methanol and sodium bicarbonate by shaking for 30 min. The extract was filtered, centrifuged, and then cleaned up on a phenyl silane column before being eluted from the washed column with methanol–water. The eluate was diluted with phosphate-buffered saline (PBS) and applied to an ochratoxin A immunoaffinity column, which was washed with water. The ochratoxin A was eluted with methanol, the solvent was evaporated, and the residue was redissolved in injection solvent. After injection of this solution onto a reversed-phase LC apparatus, ochratoxin A was measured by fluorescence detection. Eight laboratory samples of low-level naturally contaminated roasted coffee and 2 laboratory samples of blank coffee (< 0.2 ng/g ochratoxin A at the signal-to-noise ratio of 3:1), along with ampules of ochratoxin A calibrant and spiking solutions, were sent to 15 laboratories in 13 different European countries. Test portions of the laboratory samples were spiked at levels of 4 ng/g ochratoxin A, and recoveries ranged from 65 to 97%. Based on results for spiked blank material (blind duplicates) and naturally contaminated material (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 2 to 22% and the relative standard deviation for reproducibility (RSDR) ranged from 14 to 26%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low level of determination for ochratoxin A in roasted coffee.


2003 ◽  
Vol 86 (4) ◽  
pp. 685-693 ◽  
Author(s):  
Guo-Fang Pang ◽  
Yan-Zhong Cao ◽  
Chun-Lin Fan ◽  
Jin-Jie Zhang ◽  
Xue-Min Li ◽  
...  

Abstract Eighteen laboratories participated in a collaborative study on the determination of clopidol residues in chicken muscle tissues by liquid chromatography. Of these, results from 16 laboratories which rigorously followed the method were subjected to statistical analysis. The method performance was assessed by all participants using 14 samples of chicken muscle fortified at concentrations ranging from 0.1 to 5.0 mg/kg. In addition, 9 participants each reported results for 6 clopidol-incurred samples in chicken muscle. Test portions were extracted with acetonitrile, and the extracts were purified with alumina and anion exchange resin solid-phase extraction cartridges in sequence. Clopidol was separated by reversed-phase liquid chromatography and quantified at 270 nm. Average recoveries ranged from 81.8 to 85.4%, reproducibility relative standard deviation (RSDR) ranged from 11.9 to 22.6%, and repeatability relative standard deviation (RSDr) ranged from 9.9 to 15.1%. For clopidol-incurred samples at concentrations of 0.100–0.687 mg/kg, the mean determination value range was 0.099–0.659 mg/kg; RSDR was 12.6–19.8%, RSDr was 3.1–8.5%; and HORRAT values were 0.7–1.1. The accuracy and precision of the method are in conformity with the requirements specified by AOAC INTERNATIONAL. The method was adopted Official First Action in April 2003.


1994 ◽  
Vol 77 (6) ◽  
pp. 1512-1521 ◽  
Author(s):  
Mary W Trucksess ◽  
Michael E Stack ◽  
Stanley Nesheim ◽  
Richard H Albert ◽  
Thomas R Romer

Abstract An AOAC/IUPAC collaborative study was conducted to evaluate the effectiveness of a multifunctional column for the determination of aflatoxins. The test portion is extracted with acetonitrile–water (9 + 1), the extract is filtered, and the filtrate is passed through the column. The aflatoxins in the eluate are determined by reversed-phase liquid chromatography after derivatization with trifluoroacetic acid. Naturally contaminated corn, almonds, Brazil nuts, peanuts, and pistachio nuts spiked with total aflatoxins at 5,10,20, and 30 ng/g were sent to 12 collaborators in the United States, Denmark, France, Japan, and Switzerland. Eleven collaborators completed the study. Average recoveries of total aflatoxins for each spike level for the various commodities (excluding Brazil nuts at 5 ng/g) were 93,97,95, and 95%, respectively; the repeatability relative standard deviation (RSDr) ranged from 6.0 to 23.2% and the reproducibility relative standard deviation (RSDR) ranged from 12.0 to 69.4%. The multifunctional column coupled with a liquid chromatographic method for determination of aflatoxins in corn, almonds, Brazil nuts, peanuts, and pistachio nuts has been adopted first action by AOAC INTERNATIONAL.


2007 ◽  
Vol 90 (3) ◽  
pp. 765-772 ◽  
Author(s):  
Carlo Brera ◽  
Francesca Debegnach ◽  
Valentina Minardi ◽  
Elena Pannunzi ◽  
Barbara De Santis ◽  
...  

Abstract An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 levels in corn samples, enforced by European Union legislation. A test portion was extracted with methanolwater (80 + 20); the extract was filtered, diluted with phosphate-buffered saline solution, filtered on a microfiber glass filter, and applied to an immunoaffinity column. The column was washed with deionized water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase LC with fluorescence detection after either pre- or postcolumn derivatization. Precolumn derivatization was achieved by generating the trifluoroacetic acid derivative, used by 8 laboratories. The postcolumn derivatization was achieved either with pyridinium hydrobromide perbromide, used by 16 laboratories, or with an electrochemical cell by the addition of bromide to the mobile phase, used by 5 laboratories. The derivatization techniques used were not significantly different when compared by the Student's t-test; the method was statistically evaluated for all the laboratories. Five corn sample materials, both spiked and naturally contaminated, were sent to 29 laboratories (22 Italian and 7 European). Test portions were spiked with aflatoxin B1 at levels of 2.00 and 5.00 ng/g. The mean values for recovery were 82% for the low level and 84% for the high contamination level. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the values for relative standard deviation for repeatability (RSDr) ranged from 9.9 to 28.7%. The values for relative standard deviation for reproducibility (RSDR) ranged from 18.6 to 36.8%. The method demonstrated acceptable within- and between-laboratory precision for this matrix, as evidenced by the HorRat values.


2003 ◽  
Vol 86 (6) ◽  
pp. 1179-1186 ◽  
Author(s):  
Joerg Stroka ◽  
Christoph von Holst ◽  
Elke Anklam ◽  
Matthias Reutter ◽  
A Barmark ◽  
...  

Abstract A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in cattle feed at a possible future European regulatory limit (1 ng/g). The test portion was extracted with acetone–water (85 + 15), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase liquid chromatography (RP–LC) and detected by fluorescence after post column derivatization (PCD) involving bromination. PCD was achieved with either pyridinium hydrobromide perbromide (PBPB), used by 14 laboratories, or an electrochemical cell and addition of bromide to the mobile phase, used by 7 laboratories. Both derivatization techniques were not significantly different when compared by the t-test; the method was statistically evaluated for all laboratories together (bromination and PBPB). The cattle feed samples, both spiked and naturally contaminatedwithaflatoxinB1, were sent to 21 laboratories in 14 different countries (United States, Japan, and Europe). Test portions were spiked at levels of 1.2 and 3.6 ng/g for aflatoxin B1. Recoveries ranged from 74 to 157%. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally con-taminated samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 5.9 to 8.7%. The relative standard deviation for reproducibility (RSDR) ranged from 17.5 to 19.6%. The method showed acceptable within-and between-laboratory precision for this matrix, as evidenced by HORRAT values, at the target levels of determination for aflatoxin B1. No major differences in RSD were observed, showing that the composition of the feeds was not a factor for the samples tested and that the method was applicable for all materials used.