scholarly journals Column High-Performance Liquid Chromatographic Determination of Norfloxacin and Its Main Impurities in Pharmaceuticals

2008 ◽  
Vol 91 (2) ◽  
pp. 332-338 ◽  
Author(s):  
Branislava Mielji ◽  
Gordana Popovi ◽  
Danica Agbaba ◽  
Slavko Markovi ◽  
Breda Simonovska ◽  
...  

Abstract A gradient reversed-phase column high-performance liquid chromatographic method was developed for the detection and quantification of norfloxacin and its major impurities in norfloxacin-containing pharmaceuticals. Chromatographic separations were performed under the following experimental conditions: column, Zorbax SB RP-18 (5 m, 250 4.6 mm); injection volume, 20 L; mobile phase, 0.05 M NaH2PO4 (pH 2.5)acetonitrile (87 + 13) for 16 min and (58 + 42) for 9 min (stepwise gradient); and flow rate, 1.3 mL/min. All analyses were performed at 25C, and the eluate was monitored at 275 nm using a diode array detector. Linearity (correlation coefficient = 0.999), recovery (99.3101.8), relative standard deviation (0.20.7), and quantitation limit (0.120.47 g/mL) were evaluated and found to be satisfactory. The method is simple, rapid, and convenient for purity control of norfloxacin in both raw materials and dosage forms.

2008 ◽  
Vol 91 (4) ◽  
pp. 739-743 ◽  
Author(s):  
Andréia de Haro Moreno ◽  
Hérida Regina Nunes Salgado

Abstract A rapid, accurate, and sensitive high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of ceftazidime in pharmaceuticals. The method validation parameters yielded good results and included range, linearity, precision, accuracy, specificity, and recovery. The excipients in the commercial powder for injection did not interfere with the assay. Reversed-phase chromatography was used for the HPLC separation on a Waters C18 (WAT 054275; Milford, MA) column with methanolwater (70 + 30, v/v) as the mobile phase pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 245 nm. The calibration graph for ceftazidime was linear from 50.0 to 300.0 g/mL. The values for interday and intraday precision (relative standard deviation) were <1. The results obtained by the HPLC method were calculated statistically by analysis of variance. We concluded that the HPLC method is satisfactory for the determination of ceftazidime in the raw material and pharmaceuticals.


1994 ◽  
Vol 686 (1) ◽  
pp. 45-59 ◽  
Author(s):  
Rosanne C. Chloupek ◽  
William S. Hancock ◽  
Brian A. Marchylo ◽  
Joseph J. Kirkland ◽  
Barry E. Boyes ◽  
...  

2008 ◽  
Vol 91 (5) ◽  
pp. 1020-1024
Author(s):  
Raghavan Govindarajan ◽  
Dhirendra Pratap Singh ◽  
Ajay Kumar Singh Rawat

Abstract A rapid column high-performance liquid chromatographic-photodiode array method has been developed for the separation and identification of secondary metabolites, especially different types of phenols and furocoumarins, in a 35 min chromatographic run. The method has been optimized and validated for selectivity, precision, recovery, and robustness with the aim of application for standardization of selected herbal drugs. Almost all of the tested compounds had linearity of >98, with relative standard deviation <10 in terms of variation of retention time. Interday and intraday variability was <5. The developed method has been successfully applied in identification and quantification of phenols and furocoumarins present in different plants, viz., Artemisia pallens (whole plant), Hibiscus rosa-sinensis DC (flower), Heracleum candicans DC (fruit), and Ficus carica Linn (bark). The results indicate that the method is rapid, accurate, and robust for the analysis of different types of phenols and furocoumarins and, hence, can be successfully used in the quality control and standardization of plant extracts and herbal drugs.


2013 ◽  
Vol 9 (2) ◽  
pp. 26-29 ◽  
Author(s):  
AK Hemanth Kumar ◽  
V Sudha ◽  
Geetha Ramachandran

A high performance liquid chromatographic method for determination of rifabutin in human plasma was  developed. The method involved deproteinisation of the sample with acetonitrile and analysis of the  supernatant using a reversed-phase C18 column (250mm) and UV detection at a wavelength of 265nm.  The assay was specific for rifabutin and linear from 0.025 to 10.0μg/ml. The relative standard deviation  of intra- and inter-day assays was lower than 10%. The method was able to remove interfering materials  in plasma, yielding an average recovery of rifabutin from plasma of 101%. Due to its simplicity, the assay  can be used for pharmacokinetic studies of rifabutin. SAARC Journal of Tuberculosis, Lung Diseases & HIV/AIDS; 2012; IX(2) 26-29 DOI: http://dx.doi.org/10.3126/saarctb.v9i2.7975


2018 ◽  
Vol 17 (1) ◽  
pp. 123-129
Author(s):  
Sharifa Sultana ◽  
Md Shahadat Hossain ◽  
Md Samiul Islam ◽  
Abu Shara Shamsur Rouf

A novel reversed phase ultra-high performance liquid chromatographic (RP-UHPLC) method was developed for the estimation of sitagliptin in pharmaceutical dosage form. Separation was done by a X-bridge C18 column (4.6 i.d.× 150 mm, 5 μm particle size) with a flow rate of 1 ml/min using phosphate buffer (pH 6) and acetonitrile (70:30, v/v) as mobile phase at 268 nm using photodiode array plus (PDA+) detector. The retention time was found at 4.607 min. The developed method was validated as per the requirements of ICH-Q2B guidelines for specificity, system suitability, linearity, precision, accuracy, sensitivity and robustness. The linear regression analysis data for the linearity plot showed correlation coefficient values of 0.999 with LOD value of 0.06 μg/ml and LOQ of 0.225 μg/ml. The relative standard deviation (%RSD) for inter-day and intra- day precision was not more than 2.0%. The method was found to be accurate with percentages recovery of 98.50±0.03 to 99.70±0.05 and the % RSD was less than 2. The results showed that the proposed method is highly convenient for routine analysis of sitagliptin.Dhaka Univ. J. Pharm. Sci. 17(1): 123-129, 2018 (June)


Sign in / Sign up

Export Citation Format

Share Document