scholarly journals Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial

Neurosurgery ◽  
2016 ◽  
Vol 80 (1) ◽  
pp. 40-48 ◽  
Author(s):  
Tibor Becske ◽  
Waleed Brinjikji ◽  
Matthew B. Potts ◽  
David F. Kallmes ◽  
Maksim Shapiro ◽  
...  

Abstract BACKGROUND: Early and mid-term safety and efficacy of aneurysm treatment with the Pipeline Embolization Device (PED) has been well demonstrated in prior studies. OBJECTIVE: To present 5-yr follow-up for patients treated in the Pipeline for Uncoilable or Failed Aneurysms clinical trial. METHODS: In our prospective, multicenter trial, 109 complex internal carotid artery (ICA) aneurysms in 107 subjects were treated with the PED. Patients were followed per a standardized protocol at 180 d and 1, 3, and 5 yr. Aneurysm occlusion, in-stent stenosis, modified Rankin Scale scores, and complications were recorded. RESULTS: The primary endpoint of complete aneurysm occlusion at 180 d (73.6%) was previously reported. Aneurysm occlusion for those patients with angiographic follow-up progressively increased over time to 86.8% (79/91), 93.4% (71/76), and 95.2% (60/63) at 1, 3, and 5 yr, respectively. Six aneurysms (5.7%) were retreated. New serious device-related events at 1, 3, and 5 yr were noted in 1% (1/96), 3.5% (3/85), and 0% (0/81) of subjects. There were 4 (3.7%) reported deaths in our trial. Seventy-eight (96.3%) of 81 patients with 5-yr clinical follow-up had modified Rankin Scale scores ≤2. No delayed neurological deaths or hemorrhagic or ischemic cerebrovascular events were reported beyond 6 mo. No recanalization of a previously occluded aneurysm was observed. CONCLUSION: Our 5-yr findings demonstrate that PED is a safe and effective treatment for large and giant wide-necked aneurysms of the intracranial ICA, with high rates of complete occlusion and low rates of delayed adverse events.

2017 ◽  
Vol 23 (6) ◽  
pp. 614-619 ◽  
Author(s):  
Jeremy J Heit ◽  
Nicholas A Telischak ◽  
Huy M Do ◽  
Robert L Dodd ◽  
Gary K Steinberg ◽  
...  

Background Subarachnoid hemorrhage (SAH) secondary to rupture of a blister aneurysm (BA) results in high morbidity and mortality. Endovascular treatment with the pipeline embolization device (PED) has been described as a new treatment strategy for these lesions. We present the first reported case of PED retraction and foreshortening after treatment of a ruptured internal carotid artery (ICA) BA. Case description A middle-aged patient presented with SAH secondary to ICA BA rupture. The patient was treated with telescoping PED placement across the BA. After 5 days from treatment, the patient developed a new SAH due to re-rupture of the BA. Digital subtraction angiography revealed an increase in caliber of the supraclinoid ICA with associated retraction and foreshortening of the PED that resulted in aneurysm uncovering and growth. Conclusions PED should be oversized during ruptured BA treatment to prevent device retraction and aneurysm regrowth. Frequent imaging follow up after BA treatment with PED is warranted to ensure aneurysm occlusion.


2018 ◽  
Vol 25 (1) ◽  
pp. 4-11 ◽  
Author(s):  
Anna Luisa Kühn ◽  
Peter Kan ◽  
Visish Srinivasan ◽  
David E Rex ◽  
Katyucia de Macedo Rodrigues ◽  
...  

Background To evaluate the feasibility and efficacy of the pipeline embolization device in the treatment of unruptured intracranial mirror segment aneurysms. Methods Out of a total of 338 subjects, 14 were identified harboring a total of 32 internal carotid artery mirror segment aneurysms that were treated with the pipeline embolization device and were consecutively enrolled into our study. We collected data on patient demographics, modified Rankin scale (mRS) at admission, aneurysm characteristics, clinical outcome at discharge, 3–9 and at 12–18 months as well as angiography results at follow-up. Results Patients’ mean age was 52.9 years; baseline mRS was 0 in all subjects. Pipeline embolization device placement was successful in all cases. Post-treatment mRS remained 0 in 13/14 patients. One patient experienced a small intraparenchymal hemorrhage and subarachnoid hemorrhage, associated with a frontoparietal infarction resulting in right upper extremity weakness and aphasia (post-treatment mRS 3). His mRS evaluation remained stable at the 3–9-month follow-up. Three to 9-month follow-up angiography (13/14 subjects) showed complete aneurysm occlusion in 24/30 aneurysms (80%), near complete and partial occlusion in three of 30 (10%) aneurysms each. At the 9-month follow-up, one patient experienced a complete occlusion of the anterior temporal artery branch but did not present with any clinical deficits. No mRS changes were encountered over a median 6-month follow-up period. Mid-term follow-up angiography (12–18 months) available in eight of 14 subjects showed complete aneurysm occlusion in all patients. Mild intimal hyperplasia was observed in one patient. Conclusions Flow diversion technology can be used for the treatment of unruptured mirror segment aneurysms in selected patients.


2019 ◽  
Vol 10 (01) ◽  
pp. 142-144 ◽  
Author(s):  
Ching-Jen Chen ◽  
M. Rao Patibandla ◽  
Min S. Park ◽  
M. Yashar Kalani

ABSTRACTDespite the widespread use of the pipeline embolization device (PED), no complete aneurysm regrowth after its placement has been reported in the literature. We report the first case of aneurysm regrowth after the initial follow-up angiography demonstrating near-complete occlusion of the aneurysm and remodeling of the vessel with on-label PED use for a large 20 mm × 24 mm × 22 mm (width × depth × height) cavernous segment internal carotid artery (ICA) aneurysm. The patient was treated with two overlapping PED (4.5 mm × 20 mm and 5 mm × 20 mm). Follow-up angiogram at 4 months after treatment demonstrated remodeling of the ICA with a small residual component measuring approximately 7 mm × 8 mm × 7 mm. However, at 10 months after treatment, there was a complete regrowth of the aneurysm with interval growth, now measuring 25 mm × 28 mm × 18 mm. Despite the high aneurysm occlusion rates reported with the PED, persistent aneurysm filling and aneurysm regrowth, although rare, should not be overlooked.


2015 ◽  
Vol 8 (9) ◽  
pp. 945-948 ◽  
Author(s):  
Peter Kan ◽  
Edward Duckworth ◽  
Ajit Puri ◽  
Greg Velat ◽  
Ajay Wakhloo

Aneurysms that involve the internal carotid artery and posterior communicating artery junction and incorporate a fetal posterior cerebral artery are known as fetal posterior communicating artery aneurysms. We report the outcomes of four patients with fetal posterior communicating artery aneurysms who underwent treatment with the pipeline embolization device with or without adjunctive coil embolization. In our study, all four patients failed to achieve aneurysm occlusion at the last follow-up evaluation. Based on our results, we currently do not recommend the use of the flow diverter for the treatment of fetal posterior communicating artery aneurysms.


2018 ◽  
Vol 11 (5) ◽  
pp. 485-488 ◽  
Author(s):  
Amit Pujari ◽  
Brian Matthew Howard ◽  
Thomas P Madaelil ◽  
Susana Libhaber Skukalek ◽  
Anil K Roy ◽  
...  

BackgroundThe pipeline embolization device (PED) is approved for the treatment of large aneurysms of the proximal internal carotid artery (ICA). Its off-label application in treating aneurysms located specifically at the ICA terminus (ICA-T) has not been studied.MethodsWe conducted a retrospective chart review of patients from 2011 to 7 treated with PEDs. Out of 365 patients, 10 patients with ICA-T aneurysms were included. Patient demographics, procedural information, follow-up imaging, and clinical assessments were recorded.ResultsMean age was 46.9 years (± 8.8), and 6 (60%) patients were women. The mean maximum diameter of the aneurysms treated was 14.7 mm (± 10.7) and the mean neck diameter was 9.3 mm (± 6.6). Reasons for presentation included six incidental findings, one acute subarachnoid hemorrhage (SAH), and three patients with prior SAH. Kamran–Byrne Occlusion Scale scores for the treated aneurysms were as follows: three class IV (complete obliteration), four class III (<50% filling in both height and width for fusiform aneurysms or residual neck for saccular aneurysms), one class II fusiform aneurysm, 1 class 0 saccular aneurysm (residual aneurysm body), and one not classified due to pipeline thrombosis. Two clinically asymptomatic complications were noted: one patient who had a small distal cortical SAH post PED and one patient whose stent was found to be thrombosed on follow-up angiogram. All patients were seen in follow-up, and no patients were found to have worsening of their pre-procedure modified Rankin Scale score.ConclusionThe PED has potential for treating ICA-T aneurysms not amenable to conventional treatment strategies. Further studies are warranted to confirm the long term outcomes.


2016 ◽  
Vol 125 (2) ◽  
pp. 239-246 ◽  
Author(s):  
Hidetoshi Matsukawa ◽  
Rokuya Tanikawa ◽  
Hiroyasu Kamiyama ◽  
Toshiyuki Tsuboi ◽  
Kosumo Noda ◽  
...  

OBJECT The revascularization technique, including bypass created using the external carotid artery (ECA), radial artery (RA), and M2 portion of middle cerebral artery (MCA), has remained indispensable for treatment of complex aneurysms. To date, it remains unknown whether diameters of the RA, superficial temporal artery (STA), and C2 portion of the internal carotid artery (ICA) and intraoperative MCA blood pressure have influences on the outcome and the symptomatic watershed infarction (WI). The aim of the present study was to evaluate the factors for the symptomatic WI and neurological worsening in patients treated by ECA-RA-M2 bypass for complex ICA aneurysm with therapeutic ICA occlusion. METHODS The authors measured the sizes of vessels (RA, C2, M2, and STA) and intraoperative MCA blood pressure (initial, after ICA occlusion, and after releasing the RA graft bypass) in 37 patients. Symptomatic WI was defined as presence of the following: postoperative new neurological deficits, WI on postoperative diffusion-weighted imaging, and ipsilateral cerebral blood flow reduction on SPECT. Neurological worsening was defined as the increase in 1 or more modified Rankin Scale scores. First, the authors performed receiver operating characteristic curve analysis for continuous variables and the binary end point of the symptomatic WI. The clinical, radiological, and physiological characteristics of patients with and without the symptomatic WI were compared using the log-rank test. Then, the authors compared the variables between patients with and without neurological worsening at discharge and at the 12-month follow-up examination or last hospital visit. RESULTS Symptomatic WI was observed in 2 (5.4%) patients. The mean MCA pressure after releasing the RA graft (< 55 mm Hg; p = 0.017), mean (MCA pressure after releasing the RA graft)/(initial MCA pressure) (< 0.70 mm Hg; p = 0.032), and mean cross-sectional area ratio ([RA/C2 diameter]2 < 0.40 mm [p < 0.0001] and [STA/C2 diameter]2 < 0.044 mm [p < 0.0001]) were related to the symptomatic WI. All preoperatively independent patients remained independent (modified Rankin Scale score < 3). After adjusting for age and sex, left operative side (p = 0.0090 and 0.038) and perforating artery ischemia (p = 0.0050 and 0.022) were related to neurological worsening at discharge (11 [29%] patients) and at the 12-month follow-up or last hospital visit (8 [22%] patients). CONCLUSIONS Results of the present study showed that the vessel diameter and intraoperative MCA pressure had impacts on the symptomatic WI and that operative side and perforating artery ischemia were related to neurological worsening in patients with complex ICA aneurysms treated by ECA-RA-M2 bypass.


2020 ◽  
Vol 33 (2) ◽  
pp. 105-111
Author(s):  
Xianli Lv ◽  
Jianjun Yu ◽  
Ting Liao ◽  
Jin Wang ◽  
Guihuai Wang

Background and objective Giant intracavernous aneurysms (GICAs) are located in extradural space; their clinical manifestation and treatment are different from other intradural aneurysms. This study reports clinical outcomes of GICAs untolerate internal carotid artery occlusion tests. Methods Between January 2012 and September 2017, 14 consecutive cases of GICAs untolerated internal carotid artery occlusion test were retrospectively reviewed. A total of nine patients were not treated and five patients were treated using a Pipeline Embolization Device. Results Of the 14 patients, 12 had compression symptoms and 2 were incidental. In nine untreated patients, during 34 months' (range, 7–64 months) follow-up, four worsened to headaches or ablepsia (more than 34 months). One patient, who presented with ophthalmoplegia and diplopia, showed spontaneous resolution of symptoms at 32-month follow-up. Symptoms in four patients remained unchanged during less than 36-month follow-up period. In five (100%, 95% confidence interval 57% to 100%) treated patients, symptoms recovered completely during 11 months' follow-up after transient worsening of mass compression. Conclusions GICAs frequently result in intractable cranial neuropathy requiring treatment. The Pipeline Embolization Device is an effective option for these complex aneurysms in selective cases.


Sign in / Sign up

Export Citation Format

Share Document