scholarly journals Using a NPWE model observer to assess suitable image quality for a digital mammography quality assurance programme

2010 ◽  
Vol 139 (1-3) ◽  
pp. 459-462 ◽  
Author(s):  
P. Monnin ◽  
F. O. Bochud ◽  
F. R. Verdun
2018 ◽  
Vol 60 (2) ◽  
pp. 140-148
Author(s):  
Veli-Matti Sundell ◽  
Teemu Mäkelä ◽  
Alexander Meaney ◽  
Touko Kaasalainen ◽  
Sauli Savolainen

Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.


2016 ◽  
pp. ncw049
Author(s):  
Patricia Mora ◽  
Helen Khoury ◽  
Regina Bitelli ◽  
Ana Rosa Quintero ◽  
Fernando Garay ◽  
...  

2011 ◽  
Vol 175 (1) ◽  
pp. 58-62
Author(s):  
Bin Han ◽  
X. George Xu ◽  
Matt Davidson ◽  
Bryan Bednarz ◽  
Gregory C. Sharp ◽  
...  

2011 ◽  
Vol 15 (3) ◽  
pp. 70 ◽  
Author(s):  
Geoffrey K Korir ◽  
Jeska Sidika Wambani ◽  
Ian K Korir

Background. The wide use of ionising radiation in medical care has resulted in the largest man-made cause of radiation exposure. In recent years, diagnostic departments in Kenya have adapted the high-speed film/screen combination without well-established quality control, objective image quality criteria, and assessment of patient dose. The safety of patients in terms of justification and the as-low-as-reasonably-achievable (ALARA) principle is inadequate without quality assurance measures. Aim. This study assessed the level of film rejects, device performance, image quality and patient dose in 4 representative hospitals using high-speed film/screen combination. Results. The X-ray equipment quality control tests performance range was 67% to 90%, and 63% of the radiographs were of good diagnostic value. The measured prevalent chest examination entrance surface dose (ESD) showed levels above the international diagnostic reference levels (DRLs), while lumbar spine and pelvis examination was the largest source of radiation exposure to patients. Conclusion. The optimisation of patient protection can be achieved with optimally performing X-ray equipment, the application of good radiographic technique, and continuous assessment of radiographic image quality.


Author(s):  
Renata Longo ◽  
Maura Tonutti ◽  
Luigi Rigon ◽  
Fulvia Arfelli ◽  
Diego Dreossi ◽  
...  

The first clinical study of phase-contrast mammography (PCM) with synchrotron radiation was carried out at the Synchrotron Radiation for Medical Physics beamline of the Elettra synchrotron radiation facility in Trieste (Italy) in 2006–2009. The study involved 71 patients with unresolved breast abnormalities after conventional digital mammography and ultrasonography exams carried out at the Radiology Department of Trieste University Hospital. These cases were referred for mammography at the synchrotron radiation facility, with images acquired using a propagation-based phase-contrast imaging technique. To investigate the contribution of phase-contrast effects to the image quality, two experienced radiologists specialized in mammography assessed the visibility of breast abnormalities and of breast glandular structures. The images acquired at the hospital and at the synchrotron radiation facility were compared and graded according to a relative seven-grade visual scoring system. The statistical analysis highlighted that PCM with synchrotron radiation depicts normal structures and abnormal findings with higher image quality with respect to conventional digital mammography.