Determination of Low Blood Flow Limits for Arteriovenous Carbon Dioxide Removal

ASAIO Journal ◽  
1996 ◽  
Vol 42 (5) ◽  
pp. M845-849 ◽  
Author(s):  
ROBERT L. BRUNSTON ◽  
WEIKE TAO ◽  
AKHIL BIDANI ◽  
VICTOR J. CARDENAS ◽  
DANIEL L. TRABER ◽  
...  
ASAIO Journal ◽  
1996 ◽  
Vol 42 (2) ◽  
pp. 71 ◽  
Author(s):  
R. L. Brunston ◽  
W. Tao ◽  
V. J. Cardenas ◽  
A. Bidani ◽  
D. L. Traber ◽  
...  

2014 ◽  
Vol 120 (2) ◽  
pp. 416-424 ◽  
Author(s):  
Alberto Zanella ◽  
Paolo Mangili ◽  
Sara Redaelli ◽  
Vittorio Scaravilli ◽  
Marco Giani ◽  
...  

Abstract Background: Extracorporeal carbon dioxide removal has been proposed to achieve protective ventilation in patients at risk for ventilator-induced lung injury. In an acute study, the authors previously described an extracorporeal carbon dioxide removal technique enhanced by regional extracorporeal blood acidification. The current study evaluates efficacy and feasibility of such technology applied for 48 h. Methods: Ten pigs were connected to a low-flow veno-venous extracorporeal circuit (blood flow rate, 0.25 l/min) including a membrane lung. Blood acidification was achieved in eight pigs by continuous infusion of 2.5 mEq/min of lactic acid at the membrane lung inlet. The acid infusion was interrupted for 1 h at the 24 and 48 h. Two control pigs did not receive acidification. At baseline and every 8 h thereafter, the authors measured blood lactate, gases, chemistry, and the amount of carbon dioxide removed by the membrane lung (VCO2ML). The authors also measured erythrocyte metabolites and selected cytokines. Histological and metalloproteinases analyses were performed on selected organs. Results: Blood acidification consistently increased VCO2ML by 62 to 78%, from 79 ± 13 to 128 ± 22 ml/min at baseline, from 60 ± 8 to 101 ± 16 ml/min at 24 h, and from 54 ± 6 to 96 ± 16 ml/min at 48 h. During regional acidification, arterial pH decreased slightly (average reduction, 0.04), whereas arterial lactate remained lower than 4 mEq/l. No sign of organ and erythrocyte damage was recorded. Conclusion: Infusion of lactic acid at the membrane lung inlet consistently increased VCO2ML providing a safe removal of carbon dioxide from only 250 ml/min extracorporeal blood flow in amounts equivalent to 50% production of an adult man.


ASAIO Journal ◽  
1997 ◽  
Vol 43 (2) ◽  
pp. 33 ◽  
Author(s):  
R. L. Brunston ◽  
W. Tao ◽  
A. Bidani ◽  
D. L. Traber ◽  
J. B. Zwischenberger

2021 ◽  
Vol 49 (10) ◽  
pp. e1061-e1062
Author(s):  
Patrick M. Honore ◽  
Sebastien Redant ◽  
Thierry Preseau ◽  
Keitiane Kaefer ◽  
Leonel Barreto Gutierrez ◽  
...  

2014 ◽  
Vol 68 (1) ◽  
pp. 123-134
Author(s):  
Vuk Spasojevic ◽  
Slobodan Serbanovic ◽  
Predrag Stefanovic ◽  
Mirjana Kijevcanin

In this work a review of the currently available methods for carbon dioxide removal from flue gasses is given. Some of them are commercially available, while others are still under development. Special attention is given to detailed description of the methods based on hemi sorption by aqueous solutions of alkanol amines, which found wide commercial use in industry. Selection of appropriate absorbent, process equipment, methods, working parameters, combustion process etc. are some of key points that will be reviewed within this work in order to present advantages and limitations of carbon dioxide removal methods. In the experimental section density, viscosity and refractive index of insufficiently investigated carbon dioxide removal agents, such as monoisopropanolamine (MIPA), diisopropanolamine (DIPA), triisopropanolamine (TIPA) and currently widely used dietanolamine (DEA) are provided. The data obtained are crucial for the equipment design and process optimization.


ASAIO Journal ◽  
2001 ◽  
Vol 47 (2) ◽  
pp. 114
Author(s):  
Jason B. Jayroe ◽  
Dongfang Wang ◽  
Donald J. Deyo ◽  
Scott K. Alpard ◽  
Joseph B. Zwischenberger

Perfusion ◽  
2019 ◽  
Vol 34 (7) ◽  
pp. 538-543 ◽  
Author(s):  
Alice Montalti ◽  
Mirko Belliato ◽  
Sandro Gelsomino ◽  
Sandro Nalon ◽  
Francesco Matteucci ◽  
...  

Background: Extracorporeal membrane oxygenation constitutes a complex support modality, and accurate monitoring is required. An ideal monitoring system should promptly detect ECMO malfunctions and provide real-time information to optimize the patient–machine interactions. We tested a new volumetric capnometer which enables continuous monitoring of membrane lung carbon dioxide removal (V′CO2ML), to help in estimating the oxygenator performance, in terms of CO2 removal and oxygenator dead space (VDsML). Methods: This study was conducted on nine pigs undergoing veno-arterial ECMO due to cardiogenic shock after induced acute myocardial infarction. The accuracy and reliability of the prototype of the volumetric capnometer (CO2RESET™, by Eurosets srl, Medolla, Italy) device was evaluated for V′CO2ML and VDsML measurements by comparing the obtained measurements from the new device to a control capnometer with the sweep gas values. Measurements were taken at five different levels of gas flow/blood flow ratio (0.5-1.5). Agreement between the corresponding measurements was taken with the two methods. We expected that 95% of differences were between d − 1.96s and d + 1.96s. Results: In all, 120 coupled measurements from each device were obtained for the V′CO2ML calculation and 40 for the VDsML. The new capnometer mean percentage bias (95% confidence interval limits of agreement) was 3.86% (12.07-4.35%) for V′CO2ML and 2.62% (8.96-14.20%) for VDsML. A negative proportional bias for V′CO2ML estimation with the new device was observed with a mean of 3.86% (12.07-4.35%). No correlations were found between differences in the coupled V′CO2ML and VDsML measurements and the gas flow/blood flow ratio or temperature. Coupled measurements for V′CO2ML showed strong correlation (rs = 0.991; p = 0.0005), as did VDsML calculations (rs = 0.973; p = 0.0005). Conclusion: The volumetric capnometer is reliable for continuous monitoring of CO2 removal by membrane lung and VDsML calculations. Further studies are necessary to confirm these data.


Sign in / Sign up

Export Citation Format

Share Document