A Comparative Study of Computed Tomographic and Plain Radiographic Methods to Measure Vertebral Rotation in Adolescent Idiopathic Scoliosis

Spine ◽  
1992 ◽  
Vol 17 (7) ◽  
pp. 771-774 ◽  
Author(s):  
E. K. W. Ho ◽  
S. S. Upadhyay ◽  
L. Ferris ◽  
F. L. Chan ◽  
J. Bacon-Shone ◽  
...  
2016 ◽  
Vol 6 (1_suppl) ◽  
pp. s-0036-1583044-s-0036-1583044
Author(s):  
Khalil Kharrat ◽  
Amer Sebaaly ◽  
Ayman Assi ◽  
Ismat Ghanem ◽  
Rami Rachkidi

2015 ◽  
Vol 5 (1_suppl) ◽  
pp. s-0035-1554360-s-0035-1554360
Author(s):  
Dong-Gune Chang ◽  
Jin-Hyok Kim ◽  
Kee-Yong Ha ◽  
Dong-Ju Lim ◽  
Se-Il Suk

2020 ◽  
Author(s):  
Yiwei Zhao ◽  
Wubo Liu ◽  
Suomao Yuan ◽  
Yonghao Tian ◽  
Xinyu Liu

Abstract Background In the present study, we reported the clinical use of uniplanar cannulated pedicle screws for the correction of Lenke type 1 adolescent Idiopathic scoliosis (AIS), and its safety and clinical outcomes were also evaluated. Methods 68 patients with Lenke type 1 AIS were included, among which 38 patients were treated with uniplanar cannulated screws at the concave side of periapical levels and multiaxial screws at the other levels (group A). Moreover, the remaining 30 patients were treated with all multiaxial screws (group B). The preoperative and postoperative radiographic parameters of the Lenke type 1 AIS, axial vertebral rotation, and the safety of the pedicle screws were evaluated by X-rays and computed tomography (CT). Results Preoperative data was comparable between two groups. The postoperative proximal thoracic (PT) curve, main thoracic (MT) curve, thoracolumbar/lumbar (TL/L) curve, and apical vertebral rotation were significantly improved compared with the preoperative data. The coronal correction rates in group A and B were 83% and 81.9%, respectively (P > 0.05). The derotation rates in group A and B were 60.8% and 43.2%, respectively (P < 0.05). The rotation classification in the group A was also better compared with the group B. The misplacement rate in group A and B was 7.9% and 11.8%, respectively (P < 0.05), and the total misplacement rate on the concave side (11.4%) was higher than that of convex side (8.4%). The lateral perforation was found at the concave side, while the medial perforation was found at the convex side. On the concave side, the misplacement rate in group A and B was 9.7% and 12.3%, respectively (P < 0.05). The grades 2 and 3 perforations were three (3.5%) in the group A and eight (8.2%) in the group B (P < 0.05). On the convex side, the misplacement rate in group A and B was 5.9% and 11.1%, respectively (P < 0.05). The grades 2 and 3 perforations were one (0.9%) in the group A and four (4.4%) in the group B (P < 0.05). Conclusion Collectively, uniplanar cannulated pedicle screws could effectively increase the accuracy of pedicle screws and facilitate the derotation of the apical vertebra compared with the multiaxial pedicle screws. Trial registration retrospectively registered


Author(s):  
X Wang ◽  
CE Aubin ◽  
RM Schwend

The objective was to assess deformity correction and bone-screw force associated respectively with concave manipulation first, convex manipulation first, and different differential rod contouring configurations. Instrumentation scenarios were computationally simulated for 10 AIS cases with mean thoracic Cobb angle (MT) of 54±8°, apical vertebral rotation (AVR) of 19±2° and thoracic kyphosis of 21±9°. Instrumentations with major correction maneuvers using the concave side rod were first simulated; instrumentations with major correction maneuvers using the convex side rod were then simulated. Simulated correction maneuvers were concave/convex rod translation followed by apical vertebral derotation and then convex/concave rod translation. There were no significant differences in deformity corrections and bone-screw forces between concave rod translation first and convex rod translation first with differential rod contouring. Increasing differential rod contouring angle and concave rod diameter improved AVR correction and increased the TK and bone-screw forces; the effect on the MT Cobb angle was not clinically significant.


Sign in / Sign up

Export Citation Format

Share Document