C1 Pedicle Screws Versus C1 Lateral Mass Screws

Spine ◽  
2009 ◽  
Vol 34 (4) ◽  
pp. 371-377 ◽  
Author(s):  
Xiang-Yang Ma ◽  
Qing-Shui Yin ◽  
Zeng-Hui Wu ◽  
Hong Xia ◽  
Jing-Fa Liu ◽  
...  
2014 ◽  
Vol 27 (2) ◽  
pp. 80-85 ◽  
Author(s):  
Zenya Ito ◽  
Kosaku Higashino ◽  
Satoshi Kato ◽  
Sung Soo Kim ◽  
Eugene Wong ◽  
...  

2014 ◽  
Vol 36 (3) ◽  
pp. E5 ◽  
Author(s):  
Kern H. Guppy ◽  
Indro Chakrabarti ◽  
Amit Banerjee

Imaging guidance using intraoperative CT (O-arm surgical imaging system) combined with a navigation system has been shown to increase accuracy in the placement of spinal instrumentation. The authors describe 4 complex upper cervical spine cases in which the O-arm combined with the StealthStation surgical navigation system was used to accurately place occipital screws, C-1 screws anteriorly and posteriorly, C-2 lateral mass screws, and pedicle screws in C-6. This combination was also used to navigate through complex bony anatomy altered by tumor growth and bony overgrowth. The 4 cases presented are: 1) a developmental deformity case in which the C-1 lateral mass was in the center of the cervical canal causing cord compression; 2) a case of odontoid compression of the spinal cord requiring an odontoidectomy in a patient with cerebral palsy; 3) a case of an en bloc resection of a C2–3 chordoma with instrumentation from the occiput to C-6 and placement of C-1 lateral mass screws anteriorly and posteriorly; and 4) a case of repeat surgery for a non-union at C1–2 with distortion of the anatomy and overgrowth of the bony structure at C-2.


2019 ◽  
Vol 7 ◽  
pp. 2050313X1984927 ◽  
Author(s):  
Yuichi Ono ◽  
Naohisa Miyakoshi ◽  
Michio Hongo ◽  
Yuji Kasukawa ◽  
Yoshinori Ishikawa ◽  
...  

Introduction: C1 lateral mass screws and C2 pedicle screws are usually chosen to fix atlantoaxial (C1–C2) instability. However, there are a few situations in which these screws are difficult to use, such as in a case with a fracture line at the screw insertion point and bleeding from the fracture site. A new technique using a unilateral C1 posterior arch screw and a C2 laminar screw combined with a contralateral C1 lateral mass screws–C2 pedicle screws procedure for upper cervical fixation is reported. Case Report: A 24-year-old woman had an irreducible C1–C2 anterior dislocation with a type III odontoid fracture on the right side due to a traffic accident. The patient underwent open reduction and posterior C1–C2 fixation. On the left side, a C1 lateral mass screws and a C2 pedicle screws were placed. Because there was bleeding from the fracture site and a high-riding vertebral artery was seen on the right side, a C1 posterior arch screw and a C2 laminar screw were chosen. Eight months after the surgery, computed tomography scans showed healing of the odontoid fracture with anatomically correct alignment. Conclusions: Although there have been few comparable studies, fixation with unilateral C1 posterior arch screw–C2 laminar screw could be a beneficial choice for surgeries involving the upper cervical region in patients with fracture dislocation or arterial abnormalities.


2020 ◽  
Vol 8 (5) ◽  
pp. 1049-1058
Author(s):  
Hwee Weng Dennis Hey ◽  
Wen-Hai Zhuo ◽  
Yong Hao Joel Tan ◽  
Jiong Hao Tan

2013 ◽  
Vol 23 (4) ◽  
pp. 724-731 ◽  
Author(s):  
Florian Fensky ◽  
Rebecca A. Kueny ◽  
Kay Sellenschloh ◽  
Klaus Püschel ◽  
Michael M. Morlock ◽  
...  

2019 ◽  
Vol 23 (1) ◽  
pp. 1-15 ◽  
Author(s):  
Stephen Mendenhall ◽  
Dillon Mobasser ◽  
Katherine Relyea ◽  
Andrew Jea

OBJECTIVEThe evolution of pediatric spinal instrumentation has progressed in the last 70 years since the popularization of the Harrington rod showing the feasibility of placing spinal instrumentation into the pediatric spine. Although lacking in pediatric-specific spinal instrumentation, when possible, adult instrumentation techniques and tools have been adapted for the pediatric spine. A new generation of pediatric neurosurgeons with interest in complex spine disorder has pushed the field forward, while keeping the special nuances of the growing immature spine in mind. The authors sought to review their own experience with various types of spinal instrumentation in the pediatric spine and document the state of the art for pediatric spine surgery.METHODSThe authors retrospectively reviewed patients in their practice who underwent complex spine surgery. Patient demographics, operative data, and perioperative complications were recorded. At the same time, the authors surveyed the literature for spinal instrumentation techniques that have been utilized in the pediatric spine. The authors chronicle the past and present of pediatric spinal instrumentation, and speculate about its future.RESULTSThe medical records of the first 361 patients who underwent 384 procedures involving spinal instrumentation from July 1, 2007, to May 31, 2018, were analyzed. The mean age at surgery was 12 years and 6 months (range 3 months to 21 years and 4 months). The types of spinal instrumentation utilized included occipital screws (94 cases); C1 lateral mass screws (115 cases); C2 pars/translaminar screws (143 cases); subaxial cervical lateral mass screws (95 cases); thoracic and lumbar spine traditional-trajectory and cortical-trajectory pedicle screws (234 cases); thoracic and lumbar sublaminar, subtransverse, and subcostal polyester bands (65 cases); S1 pedicle screws (103 cases); and S2 alar-iliac/iliac screws (56 cases). Complications related to spinal instrumentation included hardware-related skin breakdown (1.8%), infection (1.8%), proximal junctional kyphosis (1.0%), pseudarthroses (1.0%), screw malpositioning (0.5%), CSF leak (0.5%), hardware failure (0.5%), graft migration (0.3%), nerve root injury (0.3%), and vertebral artery injury (0.3%).CONCLUSIONSPediatric neurosurgeons with an interest in complex spine disorders in children should develop a comprehensive armamentarium of safe techniques for placing rigid and nonrigid spinal instrumentation even in the smallest of children, with low complication rates. The authors’ review provides some benchmarks and outcomes for comparison, and furnishes a historical perspective of the past and future of pediatric spine surgery.


2016 ◽  
Vol 10 (4) ◽  
pp. 705 ◽  
Author(s):  
Michael Siu Hei Tse ◽  
Chi Hin Chan ◽  
Kam Kwong Wong ◽  
Wing Cheung Wong

Author(s):  
Moon-Kyu Kim ◽  
Jung-Jae Lee ◽  
Su-Hee Cho ◽  
Dai-Soon Kwak

Abstract Objective Posterior subaxial cervical screw fixation is commonly performed using the cervical pedicle screws (CPS) and lateral mass screws (LMS); however, their compatibility is low. Modified lateral mass screws (mLMS, also called paravertebral foramen screw) fixation was introduced as a salvage technique for LMS fixation and has features of both LMS and CPS techniques. In the present study, the use of mLMS as an alternative to CPS was analyzed based on clinical results. Methods Seventy-eight screws (38 CPSs and 40 mLMSs) were inserted into 12 patients. The misplacement of the screws was evaluated by computed tomography (CT). The failure of instrumentation and instability were evaluated using plain radiographs. Results The total number of CPS misplacements was 3 (10.5%); however, neurologic complications were not observed. mLMSs were used in the middle segments of the fusion in 10 patients and 2 patients had mLMS fixation for single-level fusion. An additional bridging implant was not required for connecting both CPSs and mLMSs. Instability was not observed during the observation period (4–51 months). Complete fusion was seen in 10 patients. Conclusions The alternative mLMS fixation can decrease the risk of screw misplacement compared with CPS fixation alone and achieves adequate stability leading to fusion.


Sign in / Sign up

Export Citation Format

Share Document