Plasma fibrinogen concentration is correlated with postoperative blood loss in children undergoing cardiac surgery

2014 ◽  
Vol 31 (6) ◽  
pp. 317-326 ◽  
Author(s):  
David Faraoni ◽  
Ariane Willems ◽  
Veaceslav Savan ◽  
Helene Demanet ◽  
Andree De Ville ◽  
...  
1995 ◽  
Vol 74 (04) ◽  
pp. 1064-1070 ◽  
Author(s):  
Marco Cattaneo ◽  
Alan S Harris ◽  
Ulf Strömberg ◽  
Pier Mannuccio Mannucci

SummaryThe effect of desmopressin (DDAVP) on reducing postoperative blood loss after cardiac surgery has been studied in several randomized clinical trials, with conflicting outcomes. Since most trials had insufficient statistical power to detect true differences in blood loss, we performed a meta-analysis of data from relevant studies. Seventeen randomized, double-blind, placebo-controlled trials were analyzed, which included 1171 patients undergoing cardiac surgery for various indications; 579 of them were treated with desmopressin and 592 with placebo. Efficacy parameters were blood loss volumes and transfusion requirements. Desmopressin significantly reduced postoperative blood loss by 9%, but had no statistically significant effect on transfusion requirements. A subanalysis revealed that desmopressin had no protective effects in trials in which the mean blood loss in placebo-treated patients fell in the lower and middle thirds of distribution of blood losses (687-1108 ml/24 h). In contrast, in trials in which the mean blood loss in placebo-treated patients fell in the upper third of distribution (>1109 ml/24 h), desmopressin significantly decreased postoperative blood loss by 34%. Insufficient data were available to perform a sub-analysis on transfusion requirements. Therefore, desmopressin significantly reduces blood loss only in cardiac operations which induce excessive blood loss. Further studies are called to validate the results of this meta-analysis and to identify predictors of excessive blood loss after cardiac surgery.


1994 ◽  
Vol 22 (5) ◽  
pp. 529-533 ◽  
Author(s):  
M. J. Swart ◽  
P. C. Gordon ◽  
P. B. Hayse-Gregson ◽  
R. A. Dyer ◽  
A. L. Swanepoel ◽  
...  

Fifty patients undergoing primary coronary artery bypass surgery and 50 patients undergoing valve surgery received either high-dose aprotinin (2 million units loading dose, 2 million units added to the CPB prime, and 500,000 units/hr maintenance infusion) or placebo. Mean postoperative blood loss in the first six hours was reduced from 321 ml in the placebo group to 172 ml in the aprotinin group (95% confidence interval (CI) for difference = 95 to 189 ml). Seven patients in the placebo group and 16 patients in the aprotinin group did not require transfusion with homologous blood. This study adds to the growing body of evidence that the administration of high-dose aprotinin reduces blood loss and blood transfusion requirements associated with primary cardiac surgery.


2008 ◽  
Vol 107 (2) ◽  
pp. 391-397 ◽  
Author(s):  
Andinet M. Mengistu ◽  
Kerstin D. Röhm ◽  
Joachim Boldt ◽  
Jochen Mayer ◽  
Stefan W. Suttner ◽  
...  

2014 ◽  
Vol 112 (07) ◽  
pp. 109-117 ◽  
Author(s):  
Ekaterina Baryshnikova ◽  
Armando Tripodi ◽  
Christoph J. Schlimp ◽  
Herbert Schöchl ◽  
Janne Cadamuro ◽  
...  

SummaryPlasma fibrinogen concentration is important for coagulopathy assessment, and is most commonly measured using the Clauss method. Several factors, including device type and reagent, have been shown to affect results. The study objective was to evaluate performance and repeatability of the Clauss method and to assess differences between measurements performed during and after cardiopulmonary bypass (CPB), by testing plasma samples from patients undergoing cardiac surgery with CPB. Samples were collected from 30 patients before surgery, approximately 20 minutes before weaning from CPB, and 5 minutes after CPB and protamine. Fibrinogen concentration was determined using the Clauss method at six quality-controlled specialised laboratories, according to accredited standard operating procedures. Regarding within-centre agreement for Clauss measurement, mean differences between duplicate measurements were between 0.00 g/l and 0.15 g/l, with intervals for 95% limits of agreement for mean Bland-Altman differences up to 1.3 g/l. Regarding between-centre agreement, some mean differences between pairs of centres were above 0.5 g/l. Differences of up to ∼2 g/l were observed with individual samples. Increased variability was observed between centres, with inter-class correlation values below 0.5 suggesting only fair agreement. There were no significant differences in fibrinogen concentration before weaning from CPB and after CPB for most centres and methods. In conclusion, considerable differences exist between Clauss-based plasma fibrinogen measured using different detection methods. Nevertheless, the similarity between measurements shortly before weaning from CPB and after CPB within centres suggests that on-pump measurements could provide an early estimation of fibrinogen deficit after CPB and thus guidance for haemostatic therapy.


Sign in / Sign up

Export Citation Format

Share Document