scholarly journals Comment on: Effect of eyedrops and applanation tonometry on optical biometry

2021 ◽  
Vol 47 (10) ◽  
pp. 1383-1384
Author(s):  
Maddalena De Bernardo ◽  
Aniello La Marca ◽  
Nicola Rosa
2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Zacharia Nayer ◽  
Amar Bhat ◽  
Preet K. Sohal ◽  
Braedon Murdock ◽  
Shelly H. Watson ◽  
...  

2019 ◽  
Vol 12 (2) ◽  
pp. 94-99
Author(s):  
Rene D. Mileva-Popova ◽  
Nina Y. Belova

Summary Vascular-ventricular coupling is a major determinant of left ventricular load. The aim of our study was to assess non- invasively left ventricular load and its dependency on central hemodynamics. Sixty-five healthy and gender-matched individuals were divided in two groups according to their age: 20y/o and 50y/o. Applanation tonometry was performed using the Sphygmocor device. Central pressures and pulse wave analysis indices were computed. Central systolic (120±3 vs. 98±2 mm Hg) and pulse pressures (43±3 vs. 29±1 mm Hg) as well as the augmentation index (AIx75) (23±3 vs. 6±2%) were significantly higher in the 50y/o group (p<0.01). These parameters are relevant markers of arterial stiffness and evidenced the development of central arterial morphological and functional alterations in the older subjects. The time-tension index (TTI) computed from the systolic pressure area was significantly higher in the 50y/o subjects as compared to the 20y/o group (2378±66 vs. 1954±73 mmHg×s, p<0.01). Moreover, we have shown the presence of significant correlation between TTI and AIx75 (p<0.01) in both age groups. This finding confirmed the contribution of arterial stiffness for the impaired vascular-ventricular coupling. In conclusion, applanation tonometry might be utilized for non-invasive evaluation of the left ventricular load, which is an important parameter of cardiovascular risk.


1970 ◽  
Vol 3 (2) ◽  
pp. 123-127
Author(s):  
I Paudyal ◽  
SS Thapa ◽  
G Paudyal ◽  
R Gurung ◽  
S Ruit

Background: Glaucoma is an important cause of blindness. Objective: To report the distribution of various types of glaucoma among patients presenting to a tertiary eye hospital in Nepal. Materials and methods: All new patients visiting the hospital between March 2007 and February 2008 underwent a comprehensive eye examination. Whenever glaucoma was suspected, patients were referred to fellowship-trained glaucoma specialists. Patients received a comprehensive glaucoma workup including applanation tonometry, stereoscopic examination of the optic nerve head performed by the glaucoma specialists, and a Humphrey visual field analysis (SITA 24 - 2). Results: 447 patients were newly diagnosed with glaucoma. 171 (38.2 %) patients had primary open-angle glaucoma (POAG), while 143 (32 %) had primary angle-closure glaucoma (PACG). The average age of presentation of patients with POAG was 65.78 ± 9.1 years, while the average age for PACG patients was 54.6 ±12.8 years. 30 (21 %) patients with PACG had acute angle-closure on presentation, while 113 (79 %) had chronic angle closure glaucoma. 107 (75 %) of these patients with PACG had visual acuity of less than 3/60 (20/ 400) in the worse eye at presentation. The most common form of secondary glaucoma was lens-induced (5.3 %), followed by neovascular (3.2 %) and uveitic glaucoma (3.2 %). Conclusion: The most common glaucoma seen in a tertiary referral eye hospital of Nepal is primary open-angle glaucoma. Among the angle-closure glaucoma, chronic angle-closure is the most common. Lens-induced glaucoma is still the commonest cause of secondary glaucoma. Keywords: glaucoma, open-angle, angle-closure, lens-induced DOI: http://dx.doi.org/10.3126/nepjoph.v3i2.5263 Nepal J Ophthalmol 2011; 3(2): 123-127


2008 ◽  
Vol 294 (6) ◽  
pp. H2535-H2539 ◽  
Author(s):  
David G. Edwards ◽  
Matthew S. Roy ◽  
Raju Y. Prasad

Cardiovascular events are more common in the winter months, possibly because of hemodynamic alterations in response to cold exposure. The purpose of this study was to determine the effect of acute facial cooling on central aortic pressure, arterial stiffness, and wave reflection. Twelve healthy subjects (age 23 ± 3 yr; 6 men, 6 women) underwent supine measurements of carotid-femoral pulse wave velocity (PWV), brachial artery blood pressure, and central aortic pressure (via the synthesis of a central aortic pressure waveform by radial artery applanation tonometry and generalized transfer function) during a control trial (supine rest) and a facial cooling trial (0°C gel pack). Aortic augmentation index (AI), an index of wave reflection, was calculated from the aortic pressure waveform. Measurements were made at baseline, 2 min, and 7 min during each trial. Facial cooling increased ( P < 0.05) peripheral and central diastolic and systolic pressures. Central systolic pressure increased more than peripheral systolic pressure (22 ± 3 vs. 15 ± 2 mmHg; P < 0.05), resulting in decreased pulse pressure amplification ratio. Facial cooling resulted in a robust increase in AI and a modest increase in PWV (AI: −1.4 ± 3.8 vs. 21.2 ± 3.0 and 19.9 ± 3.6%; PWV: 5.6 ± 0.2 vs. 6.5 ± 0.3 and 6.2 ± 0.2 m/s; P < 0.05). Change in mean arterial pressure but not PWV predicted the change in AI, suggesting that facial cooling may increase AI independent of aortic PWV. Facial cooling and the resulting peripheral vasoconstriction are associated with an increase in wave reflection and augmentation of central systolic pressure, potentially explaining ischemia and cardiovascular events in the cold.


2021 ◽  
Vol 11 (9) ◽  
pp. 4025
Author(s):  
Dario Messenio ◽  
Marco Ferroni ◽  
Federica Boschetti

Glaucoma is the second cause of irreversible blindness in the world. Intraocular pressure (IOP) is a recognized major risk factor for the development and progression of glaucomatous damage. Goldmann applanation tonometry (GAT) is internationally accepted as the gold standard for the measurement of IOP. The purpose of this study was to search for correlations between Goldmann tonometry and corneal mechanical properties and thickness by means of in vitro tests. IOP was measured by the Goldmann applanation tonometer (GIOP), and by a pressure transducer inserted in the anterior chamber of the eye (TIOP), at increasing pressure levels by addition of saline solution in the anterior chamber of enucleated pig eyes (n = 49). Mechanical properties were also determined by inflation tests. The GAT underestimated the real measurements made by the pressure transducer, with most common differences in the range 15–28 mmHg. The difference between the two instruments, highlighted by the Bland–Altman test, was confirmed by ANOVA, normality tests, and Mann–Whitney’s tests, both on the data arranged for infusions and for the data organized by pressure ranges. Pearson correlation tests revealed a negative correlation between (TIOP-GIOP) and both corneal stiffness and corneal thickness. In conclusion, data obtained showed a discrepancy between GIOP and TIOP more evident for softer and thinner corneas, that is very important for glaucoma detection.


Author(s):  
Linda Tallroth ◽  
Håkan Brorson ◽  
Nathalie Mobargha ◽  
Patrik Velander ◽  
Stina Klasson ◽  
...  

Abstract Background Objectively measured breast softness in reconstructed breasts and its relation to patients’ subjective satisfaction with breast softness has not yet been investigated. The aim of this study was to evaluate breast softness in patients 1 year following delayed breast reconstruction with an expander prosthesis (EP) or deep inferior epigastric perforator (DIEP) flap, using objective and subjective methods. Methods Seventy-three patients were randomised to breast reconstruction with an EP or DIEP flap between 2012 and 2018. Of these, 69 completed objective evaluation at a mean of 25 (standard deviation, SD 9.4) months following breast reconstruction. Objective evaluation included measurements of breast volume, jugulum-nipple distance, clavicular-submammary fold distance, ptosis and Baker scale grading. Breast softness was assessed with applanation tonometry. Subjective evaluation was performed using the BREAST-Q questionnaire. Results Objectively, DIEP flaps were significantly softer than EP breast reconstructions. Non-operated contralateral breasts were significantly softer compared with reconstructed breasts. In the subjective evaluation, the median score on the question (labelled 1.h) “How satisfied or dissatisfied have you been with the softness of your reconstructed breast (s)?” was higher in the DIEP flap group corresponding to greater satisfaction in this group. A fair correlation was found between the applanation tonometry and the patient-reported satisfaction with the reconstructed breast’s softness (rs = 0.37). Conclusions In terms of breast softness, breast reconstructions with DIEP flaps result in more satisfied patients. Concerning applanation tonometry as an objective tool for softness assessment, future studies on interobserver agreement are warranted. Level of evidence: Level I, therapeutic study


Sign in / Sign up

Export Citation Format

Share Document