scholarly journals Electrical Impedance Tomography to Set Positive End Expiratory Pressure During Pediatric Extracorporeal Membrane Oxygenation for Respiratory Failure... Is it Feasible?

ASAIO Journal ◽  
2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Matteo Di Nardo ◽  
Maximilian Fischer ◽  
Vito M. Ranieri
2020 ◽  
pp. 609-620 ◽  
Author(s):  
M Popková ◽  
E Kuriščák ◽  
P Hála ◽  
D Janák ◽  
L Tejkl ◽  
...  

Veno-arterial extracorporeal membrane oxygenation (VA ECMO) is a technique used in patients with severe heart failure. The aim of this study was to evaluate its effects on left ventricular afterload and fluid accumulation in lungs with electrical impedance tomography (EIT). In eight swine, incremental increases of extracorporeal blood flow (EBF) were applied before and after the induction of ischemic heart failure. Hemodynamic parameters were continuously recorded and computational analysis of EIT was used to determine lung fluid accumulation. With an increase in EBF from 1 to 4 l/min in acute heart failure the associated increase of arterial pressure (raised by 44 %) was accompanied with significant decrease of electrical impedance of lung regions. Increasing EBF in healthy circulation did not cause lung impedance changes. Our findings indicate that in severe heart failure EIT may reflect fluid accumulation in lungs due to increasing EBF.


2019 ◽  
Vol 8 (8) ◽  
pp. 1161 ◽  
Author(s):  
Thomas Muders ◽  
Benjamin Hentze ◽  
Philipp Simon ◽  
Felix Girrbach ◽  
Michael R.G. Doebler ◽  
...  

Avoiding tidal recruitment and collapse during mechanical ventilation should reduce the risk of lung injury. Electrical impedance tomography (EIT) enables detection of tidal recruitment by measuring regional ventilation delay inhomogeneity (RVDI) during a slow inflation breath with a tidal volume (VT) of 12 mL/kg body weight (BW). Clinical applicability might be limited by such high VTs resulting in high end-inspiratory pressures (PEI) during positive end-expiratory pressure (PEEP) titration. We hypothesized that RVDI can be obtained with acceptable accuracy from reduced slow inflation VTs. In seven ventilated pigs with experimental lung injury, tidal recruitment was quantified by computed tomography at PEEP levels changed stepwise between 0 and 25 cmH2O. RVDI was measured by EIT during slow inflation VTs of 12, 9, 7.5, and 6 mL/kg BW. Linear correlation of tidal recruitment and RVDI was excellent for VTs of 12 (R2 = 0.83, p < 0.001) and 9 mL/kg BW (R2 = 0.83, p < 0.001) but decreased for VTs of 7.5 (R2 = 0.76, p < 0.001) and 6 mL/kg BW (R2 = 0.71, p < 0.001). With any reduction in slow inflation VT, PEI decreased at all PEEP levels. Receiver-Operator-Characteristic curve analyses revealed that RVDI-thresholds to predict distinct amounts of tidal recruitment differ when obtained from different slow inflation VTs. In conclusion, tidal recruitment can sufficiently be monitored by EIT-based RVDI-calculation with a slow inflation of 9 mL/kg BW.


2020 ◽  
Vol 60 ◽  
pp. 38-44 ◽  
Author(s):  
Floriane Puel ◽  
Laure Crognier ◽  
Christelle Soulé ◽  
Fanny Vardon-Bounes ◽  
Stéphanie Ruiz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document