scholarly journals Comparison of Cranial Facet Joint Violation Rate Between Percutaneous and Open Pedicle Screw Placement

Medicine ◽  
2015 ◽  
Vol 94 (5) ◽  
pp. e504 ◽  
Author(s):  
Liang Wang ◽  
Yipeng Wang ◽  
Bin Yu ◽  
Zhengyao Li ◽  
Ye Li
2021 ◽  
Author(s):  
Ren-Jie Zhang ◽  
Lu-Ping Zhou ◽  
Hua-Qing Zhang ◽  
Peng Ge ◽  
Chong-Yu Jia ◽  
...  

Abstract Background Robot-assisted (RA) technique has been increasingly applied in clinical practice, providing promising outcomes of inserting accuracy and cranial facet joint protection. However, studies comparing this novel method with other assisted methods are rare, and the controversy of the superiority between the insertion techniques remains. Thus, we compare the rates and risk factors of intrapedicular accuracy and cranial facet joint violation (FJV) of RA, fluoroscopy-guided percutaneous (FP), and freehand (FH) techniques in the treatment of thoracolumbar fractures. Methods A total of 90 patients with thoracolumbar fractures requiring pedicle screw instruments were retrospectively included and divided into RA, FP, and FH groups at 1:1:1 ratio from June 2016 to May 2020. The primary outcomes were the intrapedicular accuracy and cranial FJV. The factors that affected the intrapedicular accuracy and cranial FJV were assessed using multivariate analyses.Results The optimal intrapedicular accuracy of pedicle screw placement (Grade A) in the RA, FP, and FH groups was 94.3%, 79.3%, and 88.7%, respectively. This finding indicates no significant differences between RA and FH techniques (P =0.062), but significantly higher accuracies of RA over FP (P<0.001), and FH over FP (P= 0.013). In addition, the rates of proximal FJV in RA, FP, and FH groups were 13.9%, 29.3%, and 22.7%, respectively. The RA had a significantly greater proportion of intact facet joints than the FP (P= 0.001) and FH (P= 0.035). However, FP and FH showed significantly similar outcomes with respect to the proximal FJV (P= 0.149). The logistic regression analysis showed that FP technique (OR= 2.791), pedicle angle (OR= 0.916), and L3 insertion (OR= 0.081) were independently associated with insertion accuracy. Meanwhile, the age (OR= 0.966), pedicle angle (OR= 0.940), mild facet joint osteoarthritis (OR= 5.906), moderate facet joint osteoarthritis (OR= 5.906), severe facet joint osteoarthritis (OR= 9.991), and distance from skin to insertion point (OR= 0.575) were independently associated with cranial FJV.Conclusion RA technique showed higher rate of intrapedicular accuracy and lower rate of cranial FJV than FH and FP techniques, and it might be a safe method for pedicle screw placement in thoracolumbar surgery.


Spine ◽  
2017 ◽  
Vol 42 (15) ◽  
pp. 1189-1194 ◽  
Author(s):  
Oliver Tannous ◽  
Ehsan Jazini ◽  
Tristan B. Weir ◽  
Kelley E. Banagan ◽  
Eugene Y. Koh ◽  
...  

Spine ◽  
2013 ◽  
Vol 38 (4) ◽  
pp. E251-E258 ◽  
Author(s):  
Sharon C. Yson ◽  
Jonathan N. Sembrano ◽  
Peter C. Sanders ◽  
Edward Rainier G. Santos ◽  
Charles Gerald T. Ledonio ◽  
...  

2019 ◽  
Vol 30 (5) ◽  
pp. 615-622 ◽  
Author(s):  
Xiaoguang Han ◽  
Wei Tian ◽  
Yajun Liu ◽  
Bo Liu ◽  
Da He ◽  
...  

OBJECTIVEThe object of this study was to compare the safety and accuracy of pedicle screw placement using the TiRobot system versus conventional fluoroscopy in thoracolumbar spinal surgery.METHODSPatients with degenerative or traumatic thoracolumbar spinal disorders requiring spinal instrumentation were randomly assigned to either the TiRobot-assisted group (RG) or the freehand fluoroscopy-assisted group (FG) at a 1:1 ratio. The primary outcome measure was the accuracy of screw placement according to the Gertzbein-Robbins scale; grades A and B (pedicle breach < 2 mm) were considered clinically acceptable. In the RG, discrepancies between the planned and actual screw placements were measured by merging postoperative CT images with the trajectory planning images. Secondary outcome parameters included proximal facet joint violation, duration of surgery, intraoperative blood loss, conversion to freehand approach in the RG, postoperative hospital stay, and radiation exposure.RESULTSA total of 1116 pedicle screws were implanted in 234 patients (119 in the FG, and 115 in the RG). In the RG, 95.3% of the screws were perfectly positioned (grade A); the remaining screws were graded B (3.4%), C (0.9%), and D (0.4%). In the FG, 86.1% screws were perfectly positioned (grade A); the remaining screws were graded B (7.4%), C (4.6%), D (1.4%), and E (0.5%). The proportion of clinically acceptable screws was significantly greater in the RG than in the FG (p < 0.01). In the RG, the mean deviation was 1.5 ± 0.8 mm for each screw. The most common direction of screw deviation was lateral in the RG and medial in the FG. Two misplaced screws in the FG required revision surgery, whereas no revision was required in the RG. None of the screws in the RG violated the proximal facet joint, whereas 12 screws (2.1%) in the FG violated the proximal facet joint (p < 0.01). The RG had significantly less blood loss (186.0 ± 255.3 ml) than the FG (217.0 ± 174.3 ml; p < 0.05). There were no significant differences between the two groups in terms of surgical time and postoperative hospital stay. The mean cumulative radiation time was 81.5 ± 38.6 seconds in the RG and 71.5 ± 44.2 seconds in the FG (p = 0.07). Surgeon radiation exposure was significantly less in the RG (21.7 ± 11.5 μSv) than in the FG (70.5 ± 42.0 μSv; p < 0.01).CONCLUSIONSTiRobot-guided pedicle screw placement is safe and useful in thoracolumbar spinal surgery.Clinical trial registration no.: NCT02890043 (clinicaltrials.gov)


Sign in / Sign up

Export Citation Format

Share Document