Crohn Disease Prognostication With Semiautomatic Dual-Energy Computed Tomography Enterography–Derived Iodine Density

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Bari Dane ◽  
Ahmad Garada ◽  
Thomas O'Donnell ◽  
Shannon Chang ◽  
Alec Megibow
2018 ◽  
Vol 13 (3) ◽  
pp. 709-712
Author(s):  
Narumi Taguchi ◽  
Seitaro Oda ◽  
Tateaki Kobayashi ◽  
Hideaki Naoe ◽  
Yutaka Sasaki ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jinghao Chen ◽  
Jie Zhou ◽  
Jushun Yang ◽  
Ruochen Cong ◽  
Jinjie Sun ◽  
...  

Abstract Background This retrospective study aimed to investigate the usefulness of the optimized kiloelectron volt (keV) for virtual monoenergetic imaging (VMI) combined with iodine map in dual-energy computed tomography enterography (DECTE) in the diagnosis of Crohn’s disease (CD). Methods Seventy-two patients (mean age: 41.89 ± 17.28 years) with negative computed tomography enterography (CTE) were enrolled for investigating the optimized VMI keV in DECTE by comparing subjective and objective parameters of VMIs that were reconstructed from 40 to 90 keV. Moreover, 68 patients (38.27 ± 15.10 years; 35 normal and 33 CD) were included for evaluating the diagnostic efficacy of DECTE iodine map at the optimized VMI energy level and routine CTE for CD and active CD. Statistical analysis for all data was conducted. Results Objective and subjective imaging evaluations showed the best results at 60 keV for VMIs. The CT values of the normal group, active subgroup, and CD group during the small intestinal phase at routine 120 kVp or 60 keV VMI had significant differences. The diagnostic efficacy of an iodine map was the best when NIC = 4% or fat value = 45.8% for CD, whereas NIC < 0.35 or the fat value < 0.38 for active CD. The combined routine CTE and optimized VMI improved the diagnostic efficacy (P < 0.001). Conclusions VMI at 60 keV provided the best imaging quality on DECTE. NIC and fat value provided important basis for active CD evaluation. Routine CTE combined with VMI at 60 keV improved the diagnostic efficiency for CD.


2019 ◽  
Author(s):  
Torsten Diekhoff ◽  
Michael Fuchs ◽  
Nils Engelhard ◽  
Kay-Geert Hermann ◽  
Michael Putzier ◽  
...  

2011 ◽  
Vol 12 (1) ◽  
pp. 62-63 ◽  
Author(s):  
Thomas Henzler ◽  
Steffen Diehl ◽  
Susanne Jochum ◽  
Tim Sueselbeck ◽  
Stefan O Schoenberg ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 161
Author(s):  
Masakatsu Tsurusaki ◽  
Keitaro Sofue ◽  
Masatoshi Hori ◽  
Kosuke Sasaki ◽  
Kazunari Ishii ◽  
...  

Dual-energy computed tomography (DECT) is an imaging technique based on data acquisition at two different energy settings. Recent advances in CT have allowed data acquisitions and simultaneous analyses of X-rays at two energy levels, and have resulted in novel developments in the field of abdominal imaging. The use of low and high X-ray tube voltages in DECT provide fused images that improve the detection of liver tumors owing to the higher contrast-to-noise ratio (CNR) of the tumor compared with the liver. The use of contrast agents in CT scanning improves image quality by enhancing the CNR and signal-to-noise ratio while reducing beam-hardening artifacts. DECT can improve detection and characterization of hepatic abnormalities, including mass lesions. The technique can also be used for the diagnosis of steatosis and iron overload. This article reviews and illustrates the different applications of DECT in liver imaging.


Sign in / Sign up

Export Citation Format

Share Document