scholarly journals Simultaneous evaluation of losartan and amlodipine besylate using second-derivative synchronous spectrofluorimetric technique and liquid chromatography with time-programmed fluorimetric detection

2019 ◽  
Vol 6 (4) ◽  
pp. 190310 ◽  
Author(s):  
Shereen Shalan ◽  
Jenny Jeehan Nasr

This study is concerned with two sensitive, fast and reproducible approaches; namely, second-derivative synchronous fluorimetry (method I) and reversed phase high-performance liquid chromatography with fluorimetric detection (method II) for synchronized evaluation of losartan (LOS) and amlodipine besylate (AML). Method I is based on measuring second-derivative synchronous fluorescence spectra of LOS and AML at Δ λ = 80 nm in water. The experimental factors influencing the synchronous fluorescence of the considered compounds were sensibly adjusted. The chromatographic analysis was executed on a Nucleodur MN-C18 column of dimensions; 250 × 4.6 mm i.d. and 5 µm particle size). The fluorimetric detection was time-programmed at λ em = 440 nm for AML (0.0–7.5 min) and at λ em = 400 nm for LOS (7.5–10 min) after excitation at λ ex = 245 nm. The mobile phase is a blend of acetonitrile with 0.02 M phosphate buffer in a proportion of 45 : 55, pH 4.0, pumped using a flow rate of 1 ml min −1 . The calibration plots were established to be 0.1–4.0 µg ml −1 for both drugs in method I and 0.05–4.0 µg ml −1 for both drugs in method II. The study was extended to the evaluation of the two drugs in their co-formulated tablets.

Author(s):  
Srinivasan Ms

Objective: A precise, accurate, simple, and gradient reversed-phase high-performance liquid chromatography (HPLC) method was adapted for the determination of abacavir sulfate (ABV) in combination with lamivudine (LMV) having tablet formulations simultaneously. This method developed has been validated as per the guidelines of ICH.Method: Waters HPLC has been used in the method with a column named Zorbax C18 with the dimensions as 4.6 nm×150 mm, 3.5 μm. Phosphate buffer (PH - 3.9) was used as Eluent - A, Eluent - B was methanol, and water and methanol (50:50 v/v) were utilized as diluents. The rate of flow was 1.5 ml/min.Results: The wavelength of detection has been detected at about 270 nm. Linearity ranges of ABV and LMV were 88–266 μg/ml and 38–116 μg/ml, respectively. Retention times of ABV (3.66 min) and LMV (10.71 min) were determined. The values of the study of percentage recovery of ABV and LMV were determined to be within 98.3–99.2%.Conclusion: The estimation of ABV and LMV in all pharmaceutical dosage forms could be performed successfully by employing this method.


Sign in / Sign up

Export Citation Format

Share Document