scholarly journals High-speed quantitative optical imaging of absolute metabolism in the rat cortex

2019 ◽  
Author(s):  
R. H. Wilson ◽  
C. Crouzet ◽  
M. Torabzadeh ◽  
A. Bazrafkan ◽  
N. Maki ◽  
...  

AbstractQuantitative measures of blood flow and metabolism are essential for improved assessment of brain health and response to ischemic injury. In this report, we demonstrate a multimodal technique for measuring the cerebral metabolic rate of oxygen (CMRO2) in the rodent brain on an absolute scale (μM O2 / min). We use laser speckle imaging (LSI) at 809 nm and spatial frequency domain imaging (SFDI) at 655 nm, 730 nm, and 850 nm to obtain spatiotemporal maps of cerebral blood flow (CBF), tissue absorption (μa), and tissue scattering (μs’). Knowledge of these three values enables calculation of a characteristic blood flow speed, which in turn is input to a mathematical model with a “zero-flow” boundary condition to calculate absolute CMRO2. We apply this method to a rat model of cardiac arrest (CA) and cardiopulmonary resuscitation. With this model, the zero-flow condition occurs during entry into CA. The CMRO2 values calculated with our method are in good agreement with those measured with magnetic resonance (MR) and positron emission tomography (PET) by other groups. Our technique provides a quantitative metric of cerebral metabolism that can potentially be used for comparison between animals and longitudinal monitoring of a single animal over multiple days, to assess differences in baseline metabolism and track recovery of metabolism in survival studies following ischemia and reperfusion.

Author(s):  
Makoto Ohta ◽  
Naoko Fujimura ◽  
Luca Augsburger ◽  
Hasan Yilmaz ◽  
Daniel A. Ru¨fenacht

Background and Purpose: The assessment of blood flow speed by imaging modalities is important for endovascular treatments, such as stent implantation, of cerebral aneurysms. The subtracted vortex centers path line method (SVC method) is one of the ways of determining flow speed quantitatively using the image sequence. And a cinematic angiography (CA) is a high speed image acquisition system using X-ray and contrast media integrated in Digital Subtraction Angiography (DSA) for endovascular therapy. The combination of SVC and CA may useful for determining the blood flow speed during the operation using DSA. In this study, we applied this combination to analyze hemodynamic changes before and after stenting. Methods: A transparent tubular model was constructed of silicone which included an aneurysm 10 mm in diameter and having a 5 mm neck on a straight parent artery with a diameter of 3.5 mm. The model was integrated into a pulsatile circulation system. A double layer stent was placed in the parent artery on the aneurysm. By CA, successive images at 25 frames per second with injection of contrast were obtained. Results and conclusion: Rotating vortexes of contrast, which advanced along the wall of the aneurysm, were observed in successive images of the aneurysm cavity. The movement distance of the vortex center was measured and the results show that the vortex speed decrease after stenting. This indicates the possibility of applying the SVC method to medical imaging equipment for analysis of the flow in aneurysms containing stent.


Epilepsia ◽  
1996 ◽  
Vol 37 (6) ◽  
pp. 515-521 ◽  
Author(s):  
William D. Gaillard ◽  
Thomas Zeffiro ◽  
Shahin Fazilat ◽  
Charles DeCarli ◽  
William H. Theodore

2018 ◽  
Vol 124 (4) ◽  
pp. 1107-1116 ◽  
Author(s):  
Mark Bitsch Vestergaard ◽  
Otto Mølby Henriksen ◽  
Ulrich Lindberg ◽  
Niels Jacob Aachmann-Andersen ◽  
Kristian Lisbjerg ◽  
...  

Erythropoietin (EPO) is expressed in human brain tissue, but its exact role is unknown. EPO may improve the efficiency of oxidative metabolism and has neuroprotective properties against hypoxic injuries in animal models. We aimed to investigate the effect of recombinant human EPO (rHuEPO) administration on healthy cerebral metabolism in humans during normoxia and during metabolic stress by inhalation of 10% O2hypoxic air. Twenty-four healthy men participated in a two-arm double-blind placebo-controlled trial. rHuEPO was administered as a low dose (5,000 IU) over 4 wk ( n = 12) or as a high dose (500 IU·kg body wt−1·day−1) for three consecutive days ( n = 12). Global cerebral blood flow (CBF) and metabolic rate of glucose (CMRglc) were measured with positron emission tomography. CBF, metabolic rate of oxygen ([Formula: see text]), and cerebral lactate concentration were measured by magnetic resonance imaging and spectroscopy. Low-dose treatment increased hemoglobin and was associated with a near-significant decrease in CBF during baseline normoxia. High-dose treatment caused no change in CBF. Neither treatment had an effect on normoxia CMRglc, [Formula: see text], or lactate concentration or an effect on the cerebral metabolic response to inhalation of hypoxic air. In conclusion, the study found no evidence for a direct effect of rHuEPO on cerebral metabolism.NEW & NOTEWORTHY We demonstrate with magnetic resonance imaging and positron emission tomography that administration of erythropoietin does not have a substantial direct effect on healthy human resting cerebral blood flow or effect on cerebral glucose and oxygen metabolism. Also, administration of erythropoietin did not have a direct effect on the metabolic response to acute hypoxic stress in healthy humans, and a suggested neuroprotective effect from erythropoietin is therefore likely not a direct effect of erythropoietin on cerebral metabolism.


1986 ◽  
Vol 6 (3) ◽  
pp. 335-338
Author(s):  
Hitoshi Fujii ◽  
Toshimitsu Asakura ◽  
Yasuhiro Harada ◽  
Kunihiko Nohira ◽  
Yoshihisa Shintomi ◽  
...  

2020 ◽  
Vol 11 (1) ◽  
Author(s):  
Jiang Lan Fan ◽  
Jose A. Rivera ◽  
Wei Sun ◽  
John Peterson ◽  
Henry Haeberle ◽  
...  

AbstractUnderstanding the structure and function of vasculature in the brain requires us to monitor distributed hemodynamics at high spatial and temporal resolution in three-dimensional (3D) volumes in vivo. Currently, a volumetric vasculature imaging method with sub-capillary spatial resolution and blood flow-resolving speed is lacking. Here, using two-photon laser scanning microscopy (TPLSM) with an axially extended Bessel focus, we capture volumetric hemodynamics in the awake mouse brain at a spatiotemporal resolution sufficient for measuring capillary size and blood flow. With Bessel TPLSM, the fluorescence signal of a vessel becomes proportional to its size, which enables convenient intensity-based analysis of vessel dilation and constriction dynamics in large volumes. We observe entrainment of vasodilation and vasoconstriction with pupil diameter and measure 3D blood flow at 99 volumes/second. Demonstrating high-throughput monitoring of hemodynamics in the awake brain, we expect Bessel TPLSM to make broad impacts on neurovasculature research.


Vascular ◽  
2020 ◽  
pp. 170853812093893
Author(s):  
Kazuhiro Tsunekawa ◽  
Fumio Nagai ◽  
Tamon Kato ◽  
Ikkei Takashimizu ◽  
Daisuke Yanagisawa ◽  
...  

Objectives Laser speckle flowgraphy is a technology using reflected scattered light for visualization of blood distribution, which can be used to measure relative velocity of blood flow easily without contact with the skin within a short time. It was hypothesized that laser speckle flowgraphy may be able to identify foot ischemia. This study was performed to determine whether laser speckle flowgraphy could distinguish between subjects with and without peripheral arterial disease. Materials and methods All subjects were classified based on clinical observations using the Rutherford classification: non-peripheral arterial disease, class 0; peripheral arterial disease group, class 2–5. Rutherford class 6 was one of the exclusion criteria. Laser speckle flowgraphy measured the beat strength of skin perfusion as an indicator of average dynamic cutaneous blood flow change synchronized with the heartbeat. The beat strength of skin perfusion indicates the strength of the heartbeat on the skin, and the heartbeat strength calculator in laser speckle flowgraphy uses the blood flow data to perform a Fourier transform to convert the temporal changes in blood flow to a power spectrum. A total of 33 subjects with peripheral arterial disease and 40 subjects without peripheral arterial disease at a single center were prospectively examined. Laser speckle flowgraphy was used to measure hallucal and thenar cutaneous blood flow, and the measurements were repeated three times. The hallucal and thenar index was defined as the ratio of beat strength of skin perfusion value on hallux/beat strength of skin perfusion value on ipsilateral thenar eminence. The Mann–Whitney U-test was used to compare the median values of hallucal and thenar index and ankle brachial index between the two groups. A receiver operating characteristic curve for hallucal and thenar index of beat strength of skin perfusion was plotted, and a cutoff point was set. The correlation between hallucal and thenar index of beat strength of skin perfusion and ankle brachial index was explored in all subjects, the hemodialysis group, and the non-hemodialysis (non-hemodialysis) group. Results The median value of the hallucal and thenar index of beat strength of skin perfusion was significantly different between subjects with and without peripheral arterial disease (0.27 vs. 0.87, respectively; P <  0.001). The median value of ankle brachial index was significantly different between subjects with and without peripheral arterial disease (0.8 vs. 1.1, respectively; P <  0.001). Based on the receiver operating characteristic of hallucal and thenar index, the cutoff was 0.4416 and the sensitivity, specificity, positive predictive value, and negative predictive value were 68.7%, 95%, 91.7%, and 77.6%, respectively. The correlation coefficients of all subjects, the hemodialysis group, and the non-hemodialysis group were 0.486, 0.102, and 0.743, respectively. Conclusions Laser speckle flowgraphy is a noninvasive, rapid, and widely applicable method. Laser speckle flowgraphy using hallucal and thenar index would be helpful to determine the differences between subjects with and without peripheral arterial disease. The correlation between hallucal and thenar index of beat strength of skin perfusion and ankle brachial index indicated that this index was especially useful in the non-hemodialysis group.


Sign in / Sign up

Export Citation Format

Share Document