scholarly journals Erratum: Material transport in the left ventricle with aortic valve regurgitation [Phys. Rev. Fluids 3 , 113101 (2018)]

2021 ◽  
Vol 6 (5) ◽  
Author(s):  
Giuseppe Di Labbio ◽  
Jérôme Vétel ◽  
Lyes Kadem
2019 ◽  
Vol 35 (10) ◽  
pp. S116
Author(s):  
M. Asaadi ◽  
W. Mawad ◽  
A. Djebbari ◽  
Z. Keshavarz-Motamed ◽  
L. Kadem ◽  
...  

Author(s):  
Arun Singhal ◽  
Jarrod Bang ◽  
Anthony L. Panos ◽  
Andrew Feider ◽  
Satoshi Hanada ◽  
...  

Aortic valve regurgitation in patients undergoing LVAD implantation is a significant complication which occurs in up to 10% of patients in the INTERMACS database. Patients who have aortic valve regurgitation at the time of implant have been handled by several methods, including aortic valve leaflets approximation, to aortic valve replacement or even valve closure. We report a case where we used HAART Ring to repair a regurgitant aortic valve during LAVD implant for destination therapy.


2020 ◽  
Vol 4 (5) ◽  
pp. 1-6
Author(s):  
Gilles Uijtterhaegen ◽  
Laura De Donder ◽  
Eline Ameloot ◽  
Kristof Lefebvre ◽  
Jo Van Dorpe ◽  
...  

Abstract Background Granulomatosis with polyangiitis (GPA), formerly known as Wegener’s granulomatosis, is a systemic inflammatory process predominantly affecting upper and lower respiratory tract and kidneys. Valvular heart disease is a rare manifestation of GPA. Case summary We report two cases of acute valvular heart disease mimicking acute endocarditis caused by GPA. Both patients were middle-aged females with acute aortic valve regurgitation suggestive of possible infective endocarditis. In their recent medical history, atypical otitis and sinusitis were noted. The first patient was admitted with heart failure and the second patient because of persisting fever. Echocardiogram revealed severe aortic regurgitation with an additional structure on two cusps, suggestive of infective endocarditis in both patients. Urgent surgical replacement was performed; however, intraoperative findings did not show infective endocarditis, but severe inflammatory changes of the valve and surrounding tissue. In both patients, the valve was replaced by a prosthetic valve. Microscopic examination of the valve/myocardial biopsy showed diffuse acute and chronic inflammation with necrosis and necrotizing granulomas, compatible with GPA after infectious causes were excluded. Disease remission was obtained in both patients, in one patient with Rituximab and in the other with Glucocorticoids and Cyclophosphamide. Both had an uneventful follow-up. Discussion Granulomatosis with polyangiitis can be a rare cause of acute aortic valve regurgitation mimicking infective endocarditis with the need for surgical valve replacement. Atypical ear, nose, and throat symptoms can be a first sign of GPA. Symptom recognition is important for early diagnosis and appropriate treatment to prevent further progression of the disease.


Author(s):  
Radosław Gocoł ◽  
Jarosław Bis ◽  
Marcin Malinowski ◽  
Joanna Ciosek ◽  
Damian Hudziak ◽  
...  

Abstract   OBJECTIVES The aim of this study was to compare the outcomes of tricuspid aortic valve (TAV) and bicuspid aortic valve (BAV) repair. METHODS We assessed mortality, freedom from reoperation and the rate of aortic valve regurgitation recurrence. Mortality in both groups was compared with expected survival, and risk factors for reoperation were identified. RESULTS From January 2010 to April 2020, a total of 368 elective aortic valve repair procedures were performed, including 223 (60.6%) in patients with TAV. The perioperative mortality was 0.7% in the BAV group and 3.6% in the TAV group (P = 0.079). Estimated survival at 5 years in the BAV versus TAV group was 97 ± 3% vs 80 ± 6%, respectively (P < 0.001). Freedom from reoperation at 5 years in the TAV versus BAV group was 96 ± 3% vs 93 ± 4%, respectively (P = 0.28). Grade 2 or more aortic valve regurgitation was noted in 9.9% of BAV patients and 11% of TAV patients (P = 0.66). Reoperation was predicted by cusp perforation [hazard ratio 15.86 (4.44–56.61); P < 0.001], the use of pericardial patch [hazard ratio 8.58 (1.96–37.53); P = 0.004] and aortic valve annulus diameter >27.5 mm [hazard ratio 3.07 (0.99–9.58); P = 0.053]. CONCLUSIONS BAV repair is as durable as TAV repair. BAV is not a predictor of a higher rate of reoperations. BAV repair yields survival comparable to expected. Cusp perforation, aortic valve annulus diameter >27.5 mm and the use of pericardial patch adversely impact long-term outcome of aortic valve repair.


2021 ◽  
Vol 12 ◽  
pp. 204062232110267
Author(s):  
Luxi Sun ◽  
Jinjing Liu ◽  
Xiufeng Jin ◽  
Zhimian Wang ◽  
Lu Li ◽  
...  

Background: To investigate the efficacy and safety of biologics in the perioperative management of severe aortic valve regurgitation (AR) caused by Behçet syndrome (BS). Methods: We retrospectively analyzed 20 patients with severe AR caused by BS who were all treated with biologics during the perioperative period of cardiac surgeries in our center between February 2016 and October 2020. Results: A total of 20 patients with severe AR were enrolled, including 19 males and 1 female, with a mean age of 39.1 ± 8.8 years and a median course of 8 [interquartile range (IQR) 5.25–10.00] years. Before biologic administration, 92.9% of the patients who underwent aortic valve replacement had failed conventional therapy and developed postoperative paravalvular leakage (PVL) at a median interval of 4 months. Biologics were administered with background glucocorticoids (GCs) and immunosuppressants during the perioperative period for 22 aortic valve surgeries, including preoperatively with a median interval of 3.5 (IQR 2.75–4.25) months in 13 cases and within 3 months postoperatively in 9 cases. After a median follow up of 21 (IQR 15–32) months, 2 out of 13 cases (15.4%) preoperatively, and 1 out of 9 cases (11.1%) postoperatively treated with biologics developed PVL, and the rest were event free. The Behçet’s Disease Current Activity Form score improved significantly (7 versus 0, median, p < 0.0001). Decrease of erythrocyte sedimentation rate [25.0 (IQR 11.00–36.25) mm/h versus 6.5 (IQR 4.0–8.8) mm/h, p < 0.001], and C-reactive protein [20.77 (IQR 7.19–29.58) mg/l versus 1.53 (IQR 0.94–2.92) mg/l, p = 0.001] were achieved rapidly and effectively. The GC dosage tapered from 40 (IQR 30–60) mg/d to 10 (IQR 5–11.25) mg/d, p < 0.0001. Immunosuppressants were tapered in number and dosage in 6 (30%) and 20 patients (100%), respectively. No serious adverse event was observed. Conclusion: Our study suggests that biologics were effective and well tolerated for the perioperative management of severe and refractory AR caused by BS, which significantly reduced the occurrence of postoperative PVL and had favorable GC- and immunosuppressant-sparing effect.


Sign in / Sign up

Export Citation Format

Share Document