Improving the robustness of steel frame structures under localised fire conditions

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Riza Suwondo ◽  
Lee Cunningham ◽  
Martin Gillie ◽  
Made Suangga ◽  
Irpan Hidayat

PurposeThe robustness of building structures in a fire has recently drawn wide attention. This study presents the progressive collapse analysis of steel frame building structures under localised fire. The main objective of this study is to propose methods to enhance the structural collapse resistance of such structures in fire.Design/methodology/approachA modelling method was developed and validated against both experimental and analytical studies. Then, a series of robustness analyses were performed to investigate the interaction among the members and the pattern of load distribution within the structures. These analyses show that lateral resistance and load redistribution have a vital role in the robustness of the building. Thus, two approaches have been adopted to enhance the robustness of the focused steel frame during a fire.FindingsIt is found that increased size of floor beams and vertical bracing systems are effective measures in preventing whole structure collapse. The larger beam section is able to prevent catenary action so that the load in the failed columns can safely transfer to the adjacent columns without buckling. On the other hand, the bracing system improves the lateral resistance that can accommodate the lateral force when catenary action occurs in the beam.Originality/valuePrevious studies have focused on the collapse mechanism of steel frame structures. However, the parameters affecting the structural robustness in a fire have not yet been explored. To address this gap, this study adopted numerical modelling to undertake parametric studies to identify effective methods to improve the robustness of such structures under fire conditions.

2008 ◽  
Vol 134 (7) ◽  
pp. 1070-1078 ◽  
Author(s):  
Kapil Khandelwal ◽  
Sherif El-Tawil ◽  
Sashi K. Kunnath ◽  
H. S. Lew

2012 ◽  
Vol 166-169 ◽  
pp. 1459-1464
Author(s):  
Tie Cheng Wang ◽  
Jian Kang ◽  
Zhi Ping Li ◽  
Hai Long Zhao

The key components of space steel frame structures which included 1-5 story respectively were judged by using energy method. It was shown in the results that besides interior and corner columns, adjacent side columns in low buildings should be paid attention to in analyzing progressive collapse. The approach of utilizing story as weight to modify importance factor of space frame structure was also proposed, and the modified importance factor complied better with collapse resistant characteristics of real buildings.


Sign in / Sign up

Export Citation Format

Share Document