Accurate nuclear transition data determined by prompt (n,γ)-spectrometry

2001 ◽  
Vol 50 (2) ◽  
pp. 576-579 ◽  
Author(s):  
A. Paul ◽  
S. Rottger ◽  
A. Zimbal ◽  
U. Keyser
Author(s):  
I. P. Korenkov ◽  
A. I. Ermakov ◽  
A. B. Mayzik ◽  
T. N. Laschenova ◽  
V. N. Klochkov ◽  
...  

The aim of the study is to evaluate the volume activity of radioactive waste (RW) by surface and specific alpha contamination using portable gamma-spectrometry.Materials and methods. Methods of rapid assessment of the content of α-emitting radionuclides in solid waste of various morphologies using gamma-spectrometers based on germanium detectors are considered. Computational methods for determining the effectiveness of radionuclide registration are presented.Results. The possibility of using portable gamma-ray spectrometry to assess the surface and specific activity of various materials contaminated with α-emitters (232Th, 235U, 238U, 237Np, 239Pu, 240Pu and 241Am) is shown. The calculated values of the registration efficiency of low-energy gamma-emitters obtained by modeling the spatial-energy parameters of the detector are given.To simplify the solution of this problem, the calculation program used 20 standard templates of various geometries (rectangular, cylindrical, conical, spherical, etc.). The main sources of error in the survey of contaminated surfaces, largesized equipment and building structures were investigated.Conclusions. The possibilities of portable γ-spectrometry for estimating the volume of RW based on the surface density of contamination of materials with radionuclides of uranium and transuranic elements are investigated. When using γ-spectrometer with a high-purity germanium detector with a range of γ-quanta extended in the low-energy region, radionuclides such as 232Th, 235U,238U, 237Np, 241Am were determined by their own radiation or by the radiation of their daughter products.The “problem” element is plutonium, for rapid evaluation of which it is proposed, in accordance with the radionuclide vector methodology, to use 241Am, which accumulates during the β-decay of 241Pu.According to calculations, the most likely value of the activity ratio 239Pu/241Am for the object where the work was performed (scaling factor) varies in the range from 5.0 to 9.0.Based on the results of calculations and experimental studies, the parameters of the efficiency of registration of various α-emitting radionuclides by portable γ-spectrometers. It has been found that for germanium detectors with an absolute efficiency of registering a point source of 7÷15%, it is n×10–5÷n×10–4%.


2000 ◽  
Vol 17 (9) ◽  
pp. 646-648 ◽  
Author(s):  
Zhang Zhan-Jun ◽  
Sang Jian-ping ◽  
Liu Yong

2018 ◽  
Vol 318 (3) ◽  
pp. 1837-1843
Author(s):  
S. Stoulos ◽  
E. Samartzidou ◽  
Y. Maniatis ◽  
E. Tsoukala

Author(s):  
Malathi K. Kistler ◽  
John G. Bartell ◽  
Edward A. Shipwash ◽  
Wendy R. Hatfield ◽  
Sharon E. Clare ◽  
...  

2021 ◽  
Vol 8 ◽  
Author(s):  
Charlotte Duchemin ◽  
Thomas E. Cocolios ◽  
Kristof Dockx ◽  
Gregory J. Farooq-Smith ◽  
Olaf Felden ◽  
...  

This work presents the production cross-sections of Ce, Tb and Dy radionuclides produced by 300 MeV to 1.7 GeV proton-induced spallation reactions in thin tantalum targets as well as the related Thick Target production Yield (TTY) values and ratios. The motivation is to optimise the production of terbium radionuclides for medical applications and to find out at which energy the purity of the collection by mass separation would be highest. For that purpose, activation experiments were performed using the COSY synchrotron at FZ Jülich utilising the stacked-foils technique and γ spectrometry with high-purity germanium detectors. The Al-27(p,x)Na-24 reaction has been used as monitor reaction. All experimental data have been systematically compared with the existing literature.


Sign in / Sign up

Export Citation Format

Share Document