scholarly journals Adaptive Zero-Sequence Overcurrent Criterion for Earth Fault Detection for Fault Current Passage Indicators in Resistor Grounded Medium Voltage Networks

IEEE Access ◽  
2021 ◽  
Vol 9 ◽  
pp. 63952-63965
Author(s):  
Bartosz Olejnik
2019 ◽  
Vol 84 ◽  
pp. 02008
Author(s):  
Lubomir Marciniak ◽  
Mateusz Piątek

Detection of high resistance earth faults in medium voltage networks is an important problem due to ineffectiveness of traditional earth fault protections. Such short circuits can be detected by the criterion of a reactive power of higher harmonics for zero sequence current and voltage. The main problem is determination of the power setting value in the protection, which depends on the asymmetry of phase-to-earth capacitances and higher harmonics in supply voltages, which are generated by non-linear loads. The intensive tests of the asymmetry of the zero sequence currents and voltages for harmonics and their reactive power have been carried out in 15 kV compensated network as a function of all relevant parameters, i.e.: maximum capacitance deviation of the network and protected line, percentage content of harmonics in supply voltages, capacitive current of the network and the line. It has been shown that third harmonics of the zero sequence voltage and current are the best suited for practical use, since the asymmetry reactive power of these components is the smallest among the considered harmonics and the protection sensitivity will be the highest.


Vestnik IGEU ◽  
2019 ◽  
pp. 30-41
Author(s):  
Yu.D. Kutumov ◽  
V.V. Tyutikov ◽  
T.Yu. Shadrikova ◽  
V.A. Shuin

In distribution 6–10 kV networks with an insulated neutral for earth fault protection, zero sequence current directional protection devices are commonly used. According to the operation data, the main disadvantage of such kind of protection is the possibility of their functioning failures in transient conditions with the most dangerous for network intermittent arc earth faults. It is known that most earth faults in 6–10 kV networks, primarily in the initial stage of insulation damage, have an intermittent arc. Operation failures of zero sequence current directional protection in case of arc faults reduce the operational reliability of the protected network and, as a result, the reliability of power supply to consumers. Nowadays, new developments of electrical power systems relay protection devices, including earth fault protection of medium voltage distribution electrical networks, are implemented only on a microprocessor base. Therefore, the selection and justification of the implementation principles of zero sequence current directional protection which can provide high dynamic stability of functioning is a relevant objective. When analyzing the dynamic stability of the functioning of zero sequence directional current protection, regarding the complexity of transients during intermittent arc earth faults in medium voltage electrical networks with an isolated neutral, the simulation in Matlab using SimPowerSystem and Simulink was carried out. This study focuses on transient currents and voltages as the main factor influencing dynamic stability of the functioning of zero sequence current directional protection. The impact of other factors, for example, the inaccuracies of the primary zero sequence current and voltage transducers, the scheme of formation of compared quantities, etc. was not taken into account in simulation models. The study has allowed determining the causes of possible functioning failures of digital current earth fault directional protection in dynamic operation modes. It has been shown that the usage of orthogonal components of fundamental frequency of zero sequence voltage and current in current directional protection devices eliminates the failure of their operation with any kind of arc earth faults. To ensure high dynamic stability of operation under the influence of transients during arc intermittent earth faults, current directional protection for this type of damage should be performed on the basis of monitoring the phase relationships of the fundamental frequency components of 50 Hz of zero sequence voltage and current, but not their full values.


2017 ◽  
Vol 2017 (1) ◽  
pp. 775-779 ◽  
Author(s):  
Karla Frowein ◽  
Uwe Schmidt ◽  
Gernot Druml ◽  
Peter Schegner

Energies ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 3190 ◽  
Author(s):  
Krzysztof Lowczowski ◽  
Jozef Lorenc ◽  
Jerzy Andruszkiewicz ◽  
Zbigniew Nadolny ◽  
Jozef Zawodniak

This paper presents novel zero sequence current filter and earth fault protection relay, which utilize cable screens earthing current in protection algorithm. Different problems connected with state of the art of zero sequence current filters and protection relays are presented and compared with the proposed solution. The presented concept is verified in PowerFactory simulation software, experiment concerning modeling the earth fault current flow in medium voltage (MV) cable supplied from the low voltage (LV) network and measurements in the MV network in the Polish distribution system. The proposed solution is characterized by higher sensitivity and reduced number of erroneous trips. The presented solution is suitable for any MV cable lines. Biggest advantages are observed in power output lines from renewable energy sources, which are often operated under no-load conditions.