isolated neutral
Recently Published Documents


TOTAL DOCUMENTS

108
(FIVE YEARS 40)

H-INDEX

11
(FIVE YEARS 1)

Author(s):  
M.S. Seheda ◽  
◽  
O.M. Ravlyk ◽  
Z.M. Bakhor ◽  
A.Ya. Yatseyko ◽  
...  

The results of the study of overvoltages during arc single-phase earth faults of intermittent nature in the 35 kV electric network with isolated neutral are presented. Computer simulations of transients in the electrical network have obtained the maximum multiplicities of overvoltages at the point of occurrence of single-phase arc earth faults, which exceed theoretically expected according to known theories of the occurrence and development of overvoltages. The change of the overvoltage level on the 35 kV busbars of the network substations, electrically connected to the place of occurrence of the single-phase earth fault, and the influence of the cable line on the overvoltage multiplicity are shown. Ref. 12, fig. 3, table.


2021 ◽  
Vol 2131 (3) ◽  
pp. 032045
Author(s):  
I V Belitsyn ◽  
M I Pestov ◽  
I A Pavlichenko ◽  
A I Belitsyn

Abstract The paper deals with an urgent problem - determining the location of damage to an overhead power transmission line. In particular, the application of the wavelet transform is considered, which makes it possible to localize the temporal position of the frequencies and to determine the time interval of the presence of the frequency in the event of damage to the power line. The paper presents a mathematical model that makes it possible to determine the amplitude-frequency spectrum, by which it is possible to determine the presence of a certain frequency in the signal under study, by which it is possible to determine the fault location. Based on the wavelet transform, the spectra of the current and voltage in the damaged phase in the isolated neutral mode are obtained. It is shown that when the neutral mode is switched, there are no dangerous overvoltage or current surges in the network, and the overvoltage level is reduced.


2021 ◽  
Author(s):  
Sayan Paul ◽  
Kaushik Basu

<p>Linear modulation techniques (LMTs) of an asymmetrical six-phase machine (ASPM) with two isolated neutral points synthesize the desired voltage vectors by applying at least five switching states. Different choices of applied voltage vectors, sequences in which they are used, distribution of dwell times among the redundant switching states give rise to a large number of possible LMTs. It is desirable that these LMTs avoid more than two transitions of a particular inverter leg within a carrier period. Only a subset of existing LMTs of ASPM follows this rule. Through an innovative approach, this paper finds a way to account for all possible infinitely many LMTs that follow the rule of at most two transitions per leg. Another important criterion for the selection of an LMT is its current-ripple performance. Therefore, through numerical optimization, the paper finds optimal LMTs among the above infinite possible LMTs for all reference voltage vectors in the linear range and for the whole feasible range of a machine parameter. This parameter is related to the leakage inductance of the machine and impacts the current ripple performance of ASPM. An optimal hybrid strategy is proposed with these optimal techniques, which outperforms all existing techniques in terms of the current ripple. The theoretical analysis is validated through simulation in Matlab and experiments performed up to 3.5 kW on a hardware prototype.</p>


2021 ◽  
Author(s):  
Sayan Paul ◽  
Kaushik Basu

<p>Linear modulation techniques (LMTs) of an asymmetrical six-phase machine (ASPM) with two isolated neutral points synthesize the desired voltage vectors by applying at least five switching states. Different choices of applied voltage vectors, sequences in which they are used, distribution of dwell times among the redundant switching states give rise to a large number of possible LMTs. It is desirable that these LMTs avoid more than two transitions of a particular inverter leg within a carrier period. Only a subset of existing LMTs of ASPM follows this rule. Through an innovative approach, this paper finds a way to account for all possible infinitely many LMTs that follow the rule of at most two transitions per leg. Another important criterion for the selection of an LMT is its current-ripple performance. Therefore, through numerical optimization, the paper finds optimal LMTs among the above infinite possible LMTs for all reference voltage vectors in the linear range and for the whole feasible range of a machine parameter. This parameter is related to the leakage inductance of the machine and impacts the current ripple performance of ASPM. An optimal hybrid strategy is proposed with these optimal techniques, which outperforms all existing techniques in terms of the current ripple. The theoretical analysis is validated through simulation in Matlab and experiments performed up to 3.5 kW on a hardware prototype.</p>


2021 ◽  
Vol 288 ◽  
pp. 01010
Author(s):  
Alexander Nikolaevich Kachanov ◽  
Vadim Alekseevich Chernyshov ◽  
Boris Nikolaevich Meshkov ◽  
Marsel Sharifyanovich Garifullin ◽  
Evgeny Alexandrovich Pechagin

The main objectives of this publication are: 1) to attract the attention of energy specialists to the problems of reliability and electrical safety of 6-10 kV overhead electrical networks with isolated neutral, operating in conditions of single-phase insulation damage; 2) substantiation of the feasibility of introducing a fundamentally new way to improve the efficiency of 6-10 kV distribution networks, based on the resonanceless limitation of the single-phase ground fault current arising from the breakdown of the insulator and the use of its own infrastructure of the electrical network for remote identification of the place of its occurrence. The expediency of including a nonlinear surge suppressor between the traverse and the grounding outlet of the reinforced concrete support is confirmed by the positive results of experimental studies carried out on the basis of high-voltage testing laboratories of IDGC of Center PJSC - Orelenergo and EnerGarant LLC. The use of deductive analysis allowed the authors to select a reliable and affordable electrical insulating material installed between the support and the traverse, as well as to formulate the main requirements for it, including taking into account weather and climatic factors. The analysis of various methods of transmitting information about the place of occurrence of the insulator damage made it possible to establish the predominant advantage of a wired communication channel using its own 6-10 kV electric network infrastructure. The authors have developed an original circuitry solution that provides remote identification of the insulator damage location using a thyristor shunting the nonlinear surge suppressor, according to a given switching algorithm, and also provides local identification of the insulator breakdown by means of special signaling devices with volatile power supply. It is expected that the proposed method, with relatively low investment, will significantly reduce the level of accidents and electrical hazards in overhead distribution networks of 6-10 kV, as well as minimize the costs associated with their operation and undersupply of electrical energy.


Author(s):  
Alexander Fedotov ◽  
◽  
Rafik Basyrov ◽  
Georgii Vagapov ◽  
Ainur Abdullazyanov ◽  
...  

Single-phase earth faults are one of the main problem of the distribution electrical networks with voltage 6 - 35 kV with isolated neutral. Single-phase earth fault is one of the reasons decrease of the power quality and the reliability of power supply. The paper presents the theoretical base of the monitoring parameters selection during the single-phase earth fault process and its practical implementation as an installed system at a power substation with a 110/10 kV level voltage. The hardware part of the feeder monitoring system allows implementing the determination of feeder with fault and the phase of this feeder with fault without the need to switch off of the feeders. The software part of the system allows for ongoing monitoring of feeders with built-in alarm and viewing the event archive on the supervisor computer.