scholarly journals Study on the Influence of Reignition on Electrical Life Distribution of Low-voltage Circuit Breakers

IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Zhengjun Liu ◽  
Shaopo Huang ◽  
Chengchen Zhao
1997 ◽  
Vol 33 (5) ◽  
pp. 1372
Author(s):  
P. O'Donnell ◽  
W.F. Braun ◽  
C.R. Heising ◽  
P.P. Khera ◽  
M. Kornblit ◽  
...  

2010 ◽  
Vol 25 (1) ◽  
pp. 206-211 ◽  
Author(s):  
A. Balestrero ◽  
L. Ghezzi ◽  
M. Popov ◽  
L. van der Sluis

Vestnik MGTU ◽  
2020 ◽  
Vol 23 (4) ◽  
pp. 345-353
Author(s):  
E. I. Gracheva ◽  
A. N. Gorlov ◽  
A. N. Alimova

Determination of the main characteristics of the topology and technical condition of equipment underoperating conditions is necessary for analyzing and assessing power and electricity losses in intrashoplow-voltage industrial power supply networks. A comparative analysis of the technical characteristicsof automatic circuit breakers VA57-31 (KEAZ), NSX100 TM-D (Schneider Electric), DPX3 160 (Legrand), Tmax XT1 TMD (ABB) has shown that the main technical parameters of the machines are close in their values. At that it has been found out that automatic switches of the BA57-31 series have the lowest value of power losses per pole (7.5 W), whereas the automatic switches of the Tmax XT1 TMD series have the highest value (10 W). Thus, under the operating conditions of the equipment, the lowest value of power and electricity losses is characteristic of low-voltage electrical networks with installed circuit breakers of the BA57-31 series, and the highest value of losses is noted in in-shop systems with installed circuit breakers Tmax XT1 TMD. Using catalog data, the dependences of active power losses in circuit breakers on rated currents have been established; the algorithms have been developed and the obtained dependences have been modeled using approximating functions. The standard deviation of the compiled approximating functions has been calculated. Analytical expressions of the dynamics of power losses per pole have been determined as a function of the rated current. The graphical dependences of the investigated parameters of low-voltage equipment have been presented. The developed models are recommended to be used to increase the reliability of the assessment and refinement of the amount of active power and electricity losses in low-voltage electrical networks of industrial power supply systems, agrotechnical complexes, and enterprises of the public utility sector.


Author(s):  
Jutta Rohberg ◽  
Thomas Honig ◽  
Norbert Witulski ◽  
Michael Finkbeiner ◽  
Volker Behrens

Sign in / Sign up

Export Citation Format

Share Document