scholarly journals Impact of Unbalanced-load Condition on 0-9 kHz Current Harmonics in a Three-phase Power Converter

IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Arash Moradi ◽  
Jalil Yaghoobi ◽  
Firuz Zare ◽  
Dinesh Kumar

The worldwide energy demand is increasing due to increase in population and economic growth. The grid is gradually replaced by Distributed generation systems (DGs). Recently low voltage DG interfacing converter on the non linear load compensation is performed by unified power flow converter. The proposed control technique is analyzed for Simultaneous control of voltage and power under unbalanced load condition using MATLAB/SIMULINK software


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2688 ◽  
Author(s):  
Mohammad Jafar Hadidian Moghaddam ◽  
Akhtar Kalam ◽  
Mohammad Reza Miveh ◽  
Amirreza Naderipour ◽  
Foad H. Gandoman ◽  
...  

This paper suggests an enhanced control scheme for a four-leg battery energy storage systems (BESS) under unbalanced and nonlinear load conditions operating in the isolated microgrid. Simplicity, tiny steady-state error, fast transient response, and low total harmonic distortion (THD) are the main advantages of the method. Firstly, a new decoupled per-phase model for the three-phase four-leg inverter is presented. It can eliminate the effect of power stage coupling on control design; thus, the three-phase four-leg power inverter can be viewed as three single input single output (SISO) control systems. Then, using an improved orthogonal signal generation method, the per-phase model of the four-leg inverter in the stationary and synchronous frame is derived. As the second step, a per-phase multi-loop control scheme for the four-leg inverter under unbalanced load conditions is suggested. The proposed control strategy has the ability to provide balanced output voltages under unbalanced load conditions by avoiding the need to deal with the symmetrical components. Finally, a multi-resonant harmonic compensator is used to actively prevent low-order harmonic currents to distort the output voltages of the three-phase four-leg grid-forming power converter. Simulations results are also presented to verify the performance of the suggested control strategy.


Author(s):  
Hasif Aziri ◽  
Fizatul Aini Patakor ◽  
Marizan Sulaiman ◽  
Zulhisyam Salleh

<span>This paper presents the comparative performances of Indirect Field Oriented Control (IFOC) for the three-phase induction motor. Recently, the interest of widely used the induction motor at industries because of reliability, ruggedness and almost free in maintenance. Thus, the IFOC scheme is employed to control the speed of induction motor. Therefore, P and PI controllers based on IFOC approach are analyzed at differences speed commands with no load condition. On the other hand, the PI controller is tuned based on Ziegler-Nichols method by using PSIM software which is user-friendly for simulations, design and analysis of motor drive, control loop and the power converter in power electronics studies. Subsequently, the simulated of P controller results are compared with the simulated of PI controller results at difference speed commands with no load condition. Finally, the simulated results of speed controllers are compared with the experimental results in order to explore the performances of speed responses by using IFOC scheme for three-phase induction motor drives.</span>


Sign in / Sign up

Export Citation Format

Share Document