scholarly journals Test setup design for measuring the conductance in the mechanical part of Hybrid-Circuit-Breakers before and after current commutation

IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Dirk Bosche ◽  
Patrick Vieth ◽  
Frederik Anspach ◽  
Enno Peters ◽  
Ernst-Dieter Wilkening ◽  
...  
Designs ◽  
2021 ◽  
Vol 5 (2) ◽  
pp. 28
Author(s):  
Hyosung Kim

The medium voltage DC (MVDC) type system can connect multiple terminals to a common MVDC bus, so it is possible to connect several renewable DC power sources to the common MVDC bus, but a DC circuit breaker is needed to isolate short circuit accidents that may occur in the MVDC bus. For this purpose, the concept of a hybrid DC circuit breaker that takes advantage of a low conduction loss contact type switch and an arcless-breaking semiconductor switch has been proposed. During break the hybrid switch, a dedicated current commutation device is required to temporarily bypass the load current flowing through the main switch into a semiconductor switch branch. Existing current commutation methods include a proactive method and a reverse current injection method by a LC (Inductor-capacitor) resonant circuit. This paper proposes a power circuit of a new MVDC hybrid circuit breaker using a low withstanding voltage capacitor branch for commutation and a sequence controller according to it, and verifies its operation through an experiment.


Energies ◽  
2018 ◽  
Vol 11 (5) ◽  
pp. 1086 ◽  
Author(s):  
Muhammad Nadeem ◽  
Xiaodong Zheng ◽  
Nengling Tai ◽  
Mehr Gul

2019 ◽  
Vol 47 (11) ◽  
pp. 5070-5077
Author(s):  
Xian Cheng ◽  
Peiyuan Yang ◽  
Guowei Ge ◽  
Lina Yao ◽  
Wei Xie

2015 ◽  
Vol 66 (5) ◽  
pp. 257-263 ◽  
Author(s):  
Ivica Petrović ◽  
Lajos Jozsa ◽  
Zoran Baus

Abstract In electric power systems, grid elements are often subjected to very complex and demanding disturbances or dangerous operating conditions. Determining initial fault or cause of those states is a difficult task. When fault occurs, often it is an imperative to disconnect affected grid element from the grid. This paper contains an overview of possibilities for using fuzzy logic in an assessment of primary faults in the transmission grid. The tool for this task is SCADA system, which is based on information of currents, voltages, events of protection devices and status of circuit breakers in the grid. The function model described with the membership function and fuzzy logic systems will be presented in the paper. For input data, diagnostics system uses information of protection devices tripping, states of circuit breakers and measurements of currents and voltages before and after faults.


Sign in / Sign up

Export Citation Format

Share Document